Nalu Medical, Inc. 72002-USRecalls & reported problems

Nalu Medical, Inc. · Lead Kit (8 contact, 60 cm) · Class 2 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
7
Deaths reported
0
Injuries reported
7
Recalls naming it
0

Summary

The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 00812537033624), received between Mar 10, 2022 and Mar 21, 2025 — classified as 7 injuries.

The most frequently reported specific device problem is “Insufficient Device Problem Information” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 2 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Insufficient Device Problem Information2
  • Migration2
  • Use of Device Problem2
  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Post Operative Wound Infection3
  • Inadequate Pain Relief2
  • Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
  • Insufficient Information1

Recent adverse event reports

The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.

  • InjuryMar 21, 2025Use of Device Problem; Use of Device Problem

    THE PATIENT WAS IMPLANTED WITH A NALU PERIPHERAL NERVE STIMULATOR SYSTEM ON (B)(6) 2024 TO TREAT LOWER BACK PAIN. THE PATIENT REPORTED SIGNIFICANT IMPROVEMENT IN PAIN SYMPTOMS WITH USE OF THE NALU SYSTEM, HOWEVER THE SURGICAL INCISION SITE FAILED TO PROPERLY HEAL DUE TO THE LEAD PRESSING AGAINST THE INCISION. THE PHYSICIAN ATTEMPTED TO CLOSE THE WOUND BUT WAS UNSUCCESSFUL AND EVENTUALLY NOTED VISIBLE SIGNS OF INFECTION AT THE INCISION SITE. ON (B)(6) 2025 A SURGICAL REVISION WAS PERFORMED TO REMOVE THE IPG FROM ITS ORIGINAL POSITION AND PLACE A NEW IPG IN A DIFFERENT POCKED LOCATION AS WELL AS PLACING NEW LEADS THAT WERE POSITIONED TO LAY FLAT UNDER THE SKIN SURFACE AND AVOID PRESSURE ON THE INCISION. SEE MDR 3015425075-2025-00089 . APPROXIMATELY 1 WEEK AFTER THE REVISION, THE NEW SYSTEM WAS ACTIVATED AND THE PATIENT AGAIN REPORTED GOOD PAIN RELIEF. ON (B)(6) 2025 A NALU REPRESENTATIVE WAS NOTIFIED THAT THE PATIENT WAS BEING SCHEDULED TO REMOVE THE NALU SYSTEM. PER THE PATIENT AND SPOUSE, THE INCISION SITE CONTINUES TO DRAIN AND SHOW SIGNS OF INFECTION. ON (B)(6) 2025 A FULL SYSTEM EXPLANT WAS PERFORMED. NALU PERSONNEL WERE NOT NOTIFIED OF THE PROCEDURE AHEAD OF TIME AND THUS UNABL

    Patient problems: Post Operative Wound Infection

    MAUDE report 21669765 ↗
  • InjuryMar 21, 2025Use of Device Problem; Use of Device Problem

    THE PATIENT WAS IMPLANTED WITH A NALU PERIPHERAL NERVE STIMULATOR SYSTEM ON (B)(6) 2024 TO TREAT LOWER BACK PAIN. THE PATIENT REPORTED SIGNIFICANT IMPROVEMENT IN PAIN SYMPTOMS WITH USE OF THE NALU SYSTEM, HOWEVER THE SURGICAL INCISION SITE FAILED TO PROPERLY HEAL DUE TO THE LEAD PRESSING AGAINST THE INCISION. THE PHYSICIAN ATTEMPTED TO CLOSE THE WOUND BUT WAS UNSUCCESSFUL AND EVENTUALLY NOTED VISIBLE SIGNS OF INFECTION AT THE INCISION SITE. ON (B)(6) 2025 A SURGICAL REVISION WAS PERFORMED TO REMOVE THE IPG FROM ITS ORIGINAL POSITION AND PLACE A NEW IPG IN A DIFFERENT POCKED LOCATION AS WELL AS PLACING NEW LEADS THAT WERE POSITIONED TO LAY FLAT UNDER THE SKIN SURFACE AND AVOID PRESSURE ON THE INCISION.

    Patient problems: Post Operative Wound Infection

    MAUDE report 21669747 ↗
  • InjuryAug 27, 2024Migration; Migration

    PATIENT WAS IMPLANTED WITH A NALU SPINAL CORD STIMULATOR SYSTEM ON (B)(6) 2023 AFTER PARTICIPATING IN A TRIAL PHASE AND WEAR EXPERIENCE WITH NALU. THE IMPLANTABLE PULSE GENERATOR (IPG) WAS PLACED IN THE LOWER BACK AREA AND THE IMPLANTED LEADS WERE PLACED IN THE AREA OF C2 TO TARGET THE OCCIPITAL NERVE. IN (B)(6) 2024 THE PATIENT REPORTED PAIN LEVELS HAD DECREASED FROM 8/10 DOWN TO 1/10 AND RETURNED TO WORK. IN (B)(6) 2024 THE PATIENT REPORTED LOSS OF THERAPY FROM THE SYSTEM. IMAGING WAS PERFORMED AND FIELD INVESTIGATION CONCLUDED THAT THE IMPLANTED LEADS HAD MIGRATED AWAY FROM THE INTENDED NERVE TARGET. A SURGICAL REVISION WAS PERFORMED ON (B)(6) 2024 WITH THE INTENTION OF REPOSITIONING THE MIGRATED LEADS. DURING THE PROCEDURE THE IPG WAS DAMAGED AND REQUIRED REPLACEMENT.

    Patient problems: Inadequate Pain Relief

    MAUDE report 20077033 ↗
  • InjuryAug 9, 2023Migration; Migration

    PATIENT WAS IMPLANTED WITH THE NALU SPINAL CORD STIMULATOR SYSTEM ON (B)(6) 2022 TO TREAT BILATERAL LUMBAR PAIN. APPROXIMATELY ONE WEEK AFTER IMPLANT THE PATIENT REPORTED LOSS OF PAIN RELIEF TO THE RIGHT SIDE ONLY. INVESTIGATION DETERMINED THAT ONE OF THE IMPLANTED LEADS HAD MIGRATED, MAKING TROUBLESHOOTING AND REPROGRAMMING UNSUCCESSFUL. SURGICAL REVISION WAS PERFORMED ON (B)(6) 2023 TO RELOCATE ONE LEAD TO ACHIEVE BETTER PAIN COVERAGE FOR THE RIGHT SIDE. NO COMPONENTS WERE REPLACED DURING THE PROCEDURE.

    Patient problems: Inadequate Pain Relief

    MAUDE report 17494999 ↗
  • InjuryAug 2, 2023Insufficient Device Problem Information; Insufficient Device Problem Information

    PATIENT WAS IMPLANTED WITH THE NALU SPINAL CORD STIMULATOR SYSTEM ON (B)(6) 2022. ON (B)(6) 2022 A SURGICAL REVISION WAS PERFORMED TO REPLACE THE IMPLANTED LEADS.

    Patient problems: Insufficient Information

    MAUDE report 17446940 ↗
  • InjuryJul 30, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    ON (B)(6) 2022, PATIENT WAS PREPARED TO BE IMPLANTED WITH THE NALU SPINAL CORD STIMULATOR SYSTEM. DURING THE PROCEDURE IT BECAME APARENT THAT THE PATIENT WAS NOT TOLERATING THE ANESTHESIA WELL AND THE PHYSICIAN MADE THE DETERMINATION TO ABORT THE PROCEDURE.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available

    MAUDE report 17421640 ↗
  • InjuryMar 10, 2022Insufficient Device Problem Information; Insufficient Device Problem Information

    PATIENT'S DEVICE WAS EXPLANTED DUE TO SUSPECTED INFECTION AT MIDLINE INCISION.

    Patient problems: Post Operative Wound Infection

    MAUDE report 13726688 ↗

Other Stimulator, Peripheral Nerve, Implanted (Pain Relief) devices

All Stimulator, Peripheral Nerve, Implanted (Pain Relief) devices →