Indigo SEPDRecalls & reported problems
Penumbra, Inc. · Class 2
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00814548017600), received between Apr 18, 2018 and Mar 6, 2019 — classified as 1 injury, 3 malfunctions.
The most frequently reported specific device problem is “Device Handling Problem” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Device Handling Problem3
- Break1
- Physical Resistance/Sticking1
Patient problems
- No Patient Involvement3
- No Consequences Or Impact To Patient2
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
InjuryMar 6, 2019Break; Physical Resistance/Sticking; Break; Physical Resistance/Sticking
THE PATIENT WAS UNDERGOING A THROMBECTOMY PROCEDURE IN AN ARTERIOVENOUS (AV) GRAFT IN THE LEFT ARM USING AN INDIGO SYSTEM SEPARATOR D (SEPD) AND AN INDIGO SYSTEM CATD ASPIRATION CATHETER (CATD). IT SHOULD BE NOTED THAT ACCORDING TO THE PHYSICIAN, THE GRAFT HAD BEEN CLOTTED FOR TWO WEEKS OR MORE. DURING THE PROCEDURE, THE PHYSICIAN EXPERIENCED RESISTANCE WHILE ADVANCING THE SEPD AND AN INDIGO SYSTEM CATD ASPIRATION CATHETER (CATD) IN TANDEM. HOWEVER, IT WAS ALSO REPORTED THAT THE RESISTANCE FELT DURING ADVANCEMENT WAS NOTHING MORE THAN THE PHYSICIAN NORMALLY EXPECTS IN THESE PROCEDURES. AFTER MAKING SEVERAL PASSES IN THE TARGET VESSEL WITH THE TANDEM DEVICES, THE PENUMBRA SALES REPRESENTATIVE WAS LOOKING AT THE FLUOROSCOPIC VISUALIZATION AND REALIZED THAT THE DISTAL TIP OF THE SEPD WIRE HAD BROKEN OFF AND HAD BECOME EMBEDDED IN THE THROMBUS WITHIN THE PATIENT¿S ARM. THE DEVICES WERE THEN REMOVED FROM THE PATIENT AND THE MECHANICAL THROMBECTOMY PROCEDURE WAS ENDED. UNRELATED TO THE BROKEN PIECE OF WIRE, THE PHYSICIAN DECIDED TO TRANSFER THE PATIENT TO THE OPERATING ROOM (OR) FOR AN OPEN THROMBECTOMY PROCEDURE TO REMOVE THE HEAVY CLOT BURDEN. DURING THE OPEN THROMBECTOMY PROCEDURE THE
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8397529 ↗MalfunctionMay 31, 2018Device Handling Problem; Device Handling Problem
DURING PREPARATION FOR A THROMBECTOMY PROCEDURE, THE INDIGO SYSTEM SEPARATOR D (SEPD) WAS INADVERTENTLY DROPPED BY SCRUB TECHNOLOGIST UPON REMOVAL FROM THE PACKAGING. THE REPORTED ISSUE WAS FOUND PRIOR TO USE AND THEREFORE, THE SEPD WAS NOT USED IN THE PROCEDURE. THE PROCEDURE WAS COMPLETED WITHOUT USING MORE DEVICES.
Patient problems: No Consequences Or Impact To Patient; No Patient Involvement
MAUDE report 7557197 ↗MalfunctionMay 22, 2018Device Handling Problem; Device Handling Problem
DURING PREPARATION FOR A THROMBECTOMY PROCEDURE, THE INDIGO SYSTEM SEPARATOR D (SEPD) AND THE INDIGO SYSTEM CATD ASPIRATION CATHETER (CATD) WERE DROPPED ON THE FLOOR WHILE THE SEPD WAS LOADED INSIDE THE CATD. THE REPORTED ISSUE WAS FOUND PRIOR TO USE AND THEREFORE, THE SEPD AND THE CATD WERE NOT USED IN THE PROCEDURE. THE PROCEDURE WAS COMPLETED USING A NEW DEVICE.
Patient problems: No Patient Involvement
MAUDE report 7535041 ↗MalfunctionApr 18, 2018Device Handling Problem; Device Handling Problem
DURING PREPARATION FOR A THROMBECTOMY PROCEDURE ON THE BACK TABLE, THE INDIGO SYSTEM SEPARATOR D (SEPD) WAS ACCIDENTALLY KNOCKED OFF THE TABLE ONTO THE FLOOR. THE SEPD FELL ON THE FLOOR PRIOR TO USE AND THEREFORE, IT WAS NOT USED IN THE PROCEDURE. THE PROCEDURE WAS COMPLETED USING AN INDIGO SYSTEM CATD ASPIRATION CATHETER (CATD).
Patient problems: No Patient Involvement
MAUDE report 7441941 ↗
Other Catheter, Embolectomy devices
- Indigo System CAT6Penumbra, Inc. · CATHETER, EMBOLECTOMY2 deaths408 reports
- Indigo System CATRXKITPenumbra, Inc. · Catheter, Embolectomy1 death339 reports
- Fogarty 120804FPEdwards Lifesciences LLC · Catheter, Embolectomy1 recall1 death200 reports
- LeMaitre Embolectomy Catheter 1651-88Lemaitre Vascular, Inc. · Catheter, Embolectomy1 recall161 reports
- FOGARTY 120404FPEdwards Lifesciences LLC · Catheter, Embolectomy1 recall61 reports
- Indigo System CAT6KIT-APenumbra, Inc. · Catheter, Embolectomy109 reports
- LeMaitre Embolectomy Catheter e1651-88Lemaitre Vascular, Inc. · Catheter, Embolectomy2 recalls4 reports
- Indigo System CAT8XTORQ115Penumbra, Inc. · CATHETER, EMBOLECTOMY2 deaths98 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.