SOLO PLUS Stiff Hybrid Guidewires HW35SSRecalls & reported problems
Heraeus Medical Components LLC · Class 1
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 3
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00816840020296), received between May 10, 2018 and Mar 24, 2026 — classified as 3 injuries, 1 malfunction.
The most frequently reported specific device problem is “Flaked” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Flaked2
- Activation, Positioning or Separation Problem1
- Material Fragmentation1
- Material Split, Cut or Torn1
- Material Twisted/Bent1
Patient problems
- Foreign Body In Patient2
- Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
- Blood Loss1
- Edema1
- Swelling1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
InjuryMar 24, 2026Material Fragmentation
IT WAS REPORTED THAT THE FLOPPY TIP OF THE GUIDEWIRE DETACHED DURING THE CASE. THE PHYSICIAN SPENT 1.5 HOURS RETRIEVING THE FLOPPY TIP OF THE GUIDEWIRE IN THE PATIENT. THE PHYSICIAN NOTICED AFTER THE CASE PART OF THE GUIDEWIRE WAS MISSING AND WAS ABLE TO REMOVE ALL PIECES. PATIENT WAS UNDER ANESTHESIA 1.5 LONGER THAN EXPECTED.
Patient problems: Foreign Body In Patient
MAUDE report 24683061 ↗InjuryJul 16, 2025Flaked; Material Split, Cut or Torn; Flaked; Material Split, Cut or Torn
IT WAS REPORTED THAT THE PATIENT UNDERWENT URETEROSCOPY LITHOTRIPSY FOR KIDNEY STONES. THE HYBRID GUIDEWIRE (B)(6) WAS USED FOR THE FIRST TIME. IT WAS SMOOTH AND NORMAL WHEN IT WAS INSERTED. AFTER A PERIOD OF TIME, THE STENT WAS PLACED OVER THE GUIDEWIRE. IT WAS FOUND THAT THE GREEN COATING AT THE END OF THE GUIDEWIRE FELL OFF AND WAS WRAPPED WITH THE STENT, ALMOST FALLING ON THE PATIENT. THE DOCTORS INTRAOPERATIVELY COMMUNICATED IN BETWEEN AND TRIED EVERY MEANS TO REMOVE THE COATING, WHICH HAD SOME IMPACT ON THE CLINICAL OPERATION AND PROLONGED THE OPERATION TIME. AT THE SAME TIME, THE DOCTOR HAD GREAT DOUBTS ABOUT THE QUALITY OF THE PRODUCT.
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available
MAUDE report 22522109 ↗InjuryOct 23, 2019Activation, Positioning or Separation Problem; Material Twisted/Bent
IT WAS REPORTED THAT THE WIRE AND STENT (B)(4) COILED IN THE RENAL PELVIS. A LEFT URETERAL STENT WAS ATTEMPTED. UNDER FLUOROSCOPY AS THE WIRE WAS BEING REMOVED THE STENT APPEARED TO BE BENDING AND PLEATING OVER THE WIRE. AT THIS TIME THE STENT BUT WAS NOT DISENGAGED FROM THE WIRE. SEVERAL ATTEMPTS WERE MADE TO PULL THE WIRE OUT OF THE STENT, AND IT WOULD NOT DISENGAGE. ULTIMATELY THE WIRE AND STENT WERE REMOVED THROUGH THE PENIS. THE WIRE APPEARED TO HAVE BEEN EMBEDDED AND ENGAGED HALFWAY THROUGH THE STENT., THE STENT WAS THEN CUT. ANOTHER ATTEMPT WAS MADE TO THREAD A WIRE THROUGH THIS STENT USING A HYDROPHILIC WIRE BUT UNFORTUNATELY THE TIP OF THE REMAINING STENT WAS IN THE BLADDER AND HAD ALREADY DISENGAGED THE URETERAL ORIFICE. THE CYSTOSCOPE WAS THEN REPLACED AND IT WAS NOTED THE PROCESS OF REMOVING THE STENT HAD CAUSED CONSIDERABLE SWELLING AND EDEMA AROUND THE LEFT URETERAL ORIFICE WHICH WAS ALSO BLEEDING. THE PATIENT WAS ADMITTED TO OBSERVATION AND HAD AT PLACEMENT OF A PERCUTANEOUS NEPHROSTOMY TUBE.
Patient problems: Blood Loss; Edema; Swelling
MAUDE report 9227263 ↗MalfunctionMay 10, 2018Flaked; Flaked
IT WAS REPORTED THAT "THE THE SURFACE OF THE GUIDEWIRE WAS FLAKE WHILE MANIPULATING THE DEVICE, AND A FLAKED PIECE WAS REMAINING IN THE PATIENT. A LAPAROTOMY WAS PERFORMED TO REMOVE THE REMAINING."
Patient problems: Foreign Body In Patient
MAUDE report 7503889 ↗
Other Stylet For Catheter, Gastro-Urology devices
- NiCore Nitinol Guidewire 150NSS35C. R. Bard, Inc. · STYLET FOR CATHETER, GASTRO-UROLOGY229 reports
- Sensor M0066703080Boston Scientific Corporation · STYLET FOR CATHETER, GASTRO-UROLOGY118 reports
- Sensor M0066703050Boston Scientific Corporation · STYLET FOR CATHETER, GASTRO-UROLOGY41 reports
- Bard® Hydro-Glide™ Guidewire 145FS35C. R. Bard, Inc. · STYLET FOR CATHETER, GASTRO-UROLOGY31 reports
- NiCore Nitinol Guidewire 150NFS35C. R. Bard, Inc. · STYLET FOR CATHETER, GASTRO-UROLOGY30 reports
- Amplatz Super Stiff M0066401090Boston Scientific Corporation · STYLET FOR CATHETER, GASTRO-UROLOGY21 reports
- Amplatz Super Stiff M0066401080Boston Scientific Corporation · STYLET FOR CATHETER, GASTRO-UROLOGY18 reports
- Sensor M0066703120Boston Scientific Corporation · STYLET FOR CATHETER, GASTRO-UROLOGY17 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page