SOLO PLUS Stiff Hybrid Guidewires HW35SSRecalls & reported problems

Heraeus Medical Components LLC · Class 1

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00816840020296), received between May 10, 2018 and Mar 24, 2026 — classified as 3 injuries, 1 malfunction.

The most frequently reported specific device problem is “Flaked” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Flaked2
  • Activation, Positioning or Separation Problem1
  • Material Fragmentation1
  • Material Split, Cut or Torn1
  • Material Twisted/Bent1

Patient problems

  • Foreign Body In Patient2
  • Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
  • Blood Loss1
  • Edema1
  • Swelling1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • InjuryMar 24, 2026Material Fragmentation

    IT WAS REPORTED THAT THE FLOPPY TIP OF THE GUIDEWIRE DETACHED DURING THE CASE. THE PHYSICIAN SPENT 1.5 HOURS RETRIEVING THE FLOPPY TIP OF THE GUIDEWIRE IN THE PATIENT. THE PHYSICIAN NOTICED AFTER THE CASE PART OF THE GUIDEWIRE WAS MISSING AND WAS ABLE TO REMOVE ALL PIECES. PATIENT WAS UNDER ANESTHESIA 1.5 LONGER THAN EXPECTED.

    Patient problems: Foreign Body In Patient

    MAUDE report 24683061 ↗
  • InjuryJul 16, 2025Flaked; Material Split, Cut or Torn; Flaked; Material Split, Cut or Torn

    IT WAS REPORTED THAT THE PATIENT UNDERWENT URETEROSCOPY LITHOTRIPSY FOR KIDNEY STONES. THE HYBRID GUIDEWIRE (B)(6) WAS USED FOR THE FIRST TIME. IT WAS SMOOTH AND NORMAL WHEN IT WAS INSERTED. AFTER A PERIOD OF TIME, THE STENT WAS PLACED OVER THE GUIDEWIRE. IT WAS FOUND THAT THE GREEN COATING AT THE END OF THE GUIDEWIRE FELL OFF AND WAS WRAPPED WITH THE STENT, ALMOST FALLING ON THE PATIENT. THE DOCTORS INTRAOPERATIVELY COMMUNICATED IN BETWEEN AND TRIED EVERY MEANS TO REMOVE THE COATING, WHICH HAD SOME IMPACT ON THE CLINICAL OPERATION AND PROLONGED THE OPERATION TIME. AT THE SAME TIME, THE DOCTOR HAD GREAT DOUBTS ABOUT THE QUALITY OF THE PRODUCT.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available

    MAUDE report 22522109 ↗
  • InjuryOct 23, 2019Activation, Positioning or Separation Problem; Material Twisted/Bent

    IT WAS REPORTED THAT THE WIRE AND STENT (B)(4) COILED IN THE RENAL PELVIS. A LEFT URETERAL STENT WAS ATTEMPTED. UNDER FLUOROSCOPY AS THE WIRE WAS BEING REMOVED THE STENT APPEARED TO BE BENDING AND PLEATING OVER THE WIRE. AT THIS TIME THE STENT BUT WAS NOT DISENGAGED FROM THE WIRE. SEVERAL ATTEMPTS WERE MADE TO PULL THE WIRE OUT OF THE STENT, AND IT WOULD NOT DISENGAGE. ULTIMATELY THE WIRE AND STENT WERE REMOVED THROUGH THE PENIS. THE WIRE APPEARED TO HAVE BEEN EMBEDDED AND ENGAGED HALFWAY THROUGH THE STENT., THE STENT WAS THEN CUT. ANOTHER ATTEMPT WAS MADE TO THREAD A WIRE THROUGH THIS STENT USING A HYDROPHILIC WIRE BUT UNFORTUNATELY THE TIP OF THE REMAINING STENT WAS IN THE BLADDER AND HAD ALREADY DISENGAGED THE URETERAL ORIFICE. THE CYSTOSCOPE WAS THEN REPLACED AND IT WAS NOTED THE PROCESS OF REMOVING THE STENT HAD CAUSED CONSIDERABLE SWELLING AND EDEMA AROUND THE LEFT URETERAL ORIFICE WHICH WAS ALSO BLEEDING. THE PATIENT WAS ADMITTED TO OBSERVATION AND HAD AT PLACEMENT OF A PERCUTANEOUS NEPHROSTOMY TUBE.

    Patient problems: Blood Loss; Edema; Swelling

    MAUDE report 9227263 ↗
  • MalfunctionMay 10, 2018Flaked; Flaked

    IT WAS REPORTED THAT "THE THE SURFACE OF THE GUIDEWIRE WAS FLAKE WHILE MANIPULATING THE DEVICE, AND A FLAKED PIECE WAS REMAINING IN THE PATIENT. A LAPAROTOMY WAS PERFORMED TO REMOVE THE REMAINING."

    Patient problems: Foreign Body In Patient

    MAUDE report 7503889 ↗

Other Stylet For Catheter, Gastro-Urology devices