InCore Lapidus IC-LAP-0101LRecalls & reported problems
Medartis Inc. · Targeting Guide Assembly Left Reusable · Class 2
All models of InCore Lapidus (6)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00817701021162), received between Jul 20, 2018 and Jul 20, 2018 — classified as 1 malfunction.
The most frequently reported specific device problem is “Mechanical Jam” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Mechanical Jam1
- Physical Resistance/Sticking1
Patient problems
- Bone Fracture(s)1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 20, 2018Mechanical Jam; Physical Resistance/Sticking; Mechanical Jam; Physical Resistance/Sticking
IT WAS REPORTED THAT, DURING A LAPIDUS PROCEDURE OF THE 1ST TMT JOINT, A DRILL BIT SEIZED IN THE TARGETING GUIDE INSTRUMENT. THE TARGETING GUIDE WAS REMOVED AND DURING THE REMOVAL THE SURGEON STATED THAT THE MEDIAL CUNEIFORM FRACTURED DISTALLY INTO THE FUSION SITE. THE REMOVAL OF THE INSTRUMENT AND THE FRACTURED CUNEIFORM CAUSED A 30-MINUTE SURGICAL DELAY. THE FRACTURE WAS PLATED AS WELL AS THE LAPIDUS PROCEDURE COMPLETED WITH A TYPICAL PLATE AND SCREW APPROACH WITHOUT ANY SUBSEQUENT ISSUE.
Patient problems: Bone Fracture(s)
MAUDE report 7706540 ↗
FDA clearance and classification
The FDA regulates product code HWC (screw, fixation, bone) under 21 CFR 888.3040 as a Class II device. 21 CFR 888.3040 ↗
Devices of this type normally need 510(k) clearance before sale.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the InCore Lapidus IC-LAP-0101L
Has the InCore Lapidus IC-LAP-0101L been recalled?
No FDA recall record in our data names this exact device identifier (DI 00817701021162), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the InCore Lapidus IC-LAP-0101L?
The FDA's MAUDE database lists 1 adverse event report for this device, received on Jul 20, 2018. That report lists device problems “Mechanical Jam” (1) and “Physical Resistance/Sticking” (1); patient problem “Bone Fracture(s)” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the InCore Lapidus IC-LAP-0101L?
None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Who makes the InCore Lapidus IC-LAP-0101L, and is it still sold?
The FDA's device database lists Medartis Inc. as the company responsible for it (brand InCore Lapidus, model IC-LAP-0101L). Its record shows it as no longer in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Screw, Fixation, Bone devices
- NA 03.043.029Synthes GmbH · Screw, fixation, bone498 reports
- OSTEORAPTOR 72201995Smith & Nephew, Inc. · Screw, fixation, bone248 reports
- Control 360 SK12Treace Medical Concepts, Inc. · Screw, Fixation, Bone195 reports
- HEALIX PEEK ORTHOCORD 222205Medos International Sàrl · Screw, fixation, bone186 reports
- PRECICE® Bone Transport System STP3.5-200Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-325Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-550Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-425Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page