Cannulated Compression Headless Screw 04.333.226TSRecalls & reported problems

Tyber Medical, LLC · 3.0MM TI CANN COMPRESSION HEADLESS SCREW- ST- 26MM · Class 2 · Implant

All models of Cannulated Compression Headless Screw (21)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00819917027495), received between Nov 17, 2023 and Nov 29, 2023 — classified as 1 injury, 1 malfunction.

The most frequently reported specific device problem is “Insufficient Device Problem Information” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 2 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1
  • Insufficient Device Problem Information1

Patient problems

  • Insufficient Information2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionNov 29, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE PATIENT DID NOT DEVELOP A SURGICAL SITE INFECTION. HE HAD SOME DELAYED WOUND HEALING RELATED TO THAT TWO CCHS IMPLANTS WERE IMPLANTED, RECEIVED ON THROUGH (B)(4).DR (B)(6) STATED THAT THE PATIENT WAS CURRENTLY HAPPY AND WOULD SEE HIM AGAIN IN 4 WEEKS. IF REVISION SURGERY IS HAPPY, DR (B)(6) WILL REMOVE DRILL FRAGMENT AT THAT TIME. IF NOT, HE HAS STATED THAT HE WILL LEAVE IT WHERE IT IS. X-RAY REVEALED: SCREW HAS MIGRATED SLIGHTLY AND DRILL BIT FRAGMENT IDENTIFIED. THE FRAGMENTS GENERATED ARE FROM AN UNKNOWN DRILL DEVICE NOT MADE AT TYBER MEDICAL.

    Patient problems: Insufficient Information

    MAUDE report 18228801 ↗
  • InjuryNov 17, 2023Insufficient Device Problem Information; Insufficient Device Problem Information

    PERFORMED AN IPJ FUSION USING CCHS. THIS INSTRUMENT SET USED WAS THE SET ON THE SHELF THAT CONTAINED THE REUSABLE 2.0MM DRILL BIT (310.221). WHEN DRILLING FOR THE SCREW THE DRILL BIT BROKE INTO PIECES. BITS WERE REMOVED AS BEST AS POSSIBLE AND FRESH DRILL BIT WAS USED FROM ANOTHER KIT. SCREW WAS INSERTED SUCCESSFULLY. ON FINAL X- RAYS THERE WAS NOT VISIBLE REMNANTS OF THE BROKEN DRILL BIT. WHEN GUIDE WIRE WAS REMOVED IT WAS IDENTIFIED TO HAVE A SLIGHT BEND TO IT. IF OTHER, DESCRIBE IPJ FUSION LEFT SIDE, WAS SURGERY DELAYED DUE TO THE REPORTED EVENT? YES, IF YES, NUMBER OF MINUTES: 30 MINUTES, ACTION TAKEN WHEN EVENT OCCURRED? METAL ITEMS WERE REMOVED , WAS PROCEDURE SUCCESSFULLY COMPLETED? YES, WERE FRAGMENTS GENERATED? YES, IF YES, WERE THEY REMOVED EASILY WITHOUT ADDITIONAL INTERVENTION? NO, IF NO, EXPLAIN: ITEMS WERE REMOVED USING VARIOUS INSTRUMENTS. AS MENTIONED ON FINAL X-RAY NO FRAGMENTS WERE VISIBLE, PATIENT STATUS/ OUTCOME / CONSEQUENCES NO, WAS OTHER MEDICAL INTERVENTION (E.G. X-RAYS, ADDITIONAL PROCEDURES, PRESCRIPTIONS, OTC, REVISION) REQUIRED: YES, IF YES, DESCRIBE EXTRA TIME AND X-RAYS USING FLUOROSCOPY WERE NEEDED, IS THE PATIENT PART OF A CLINICAL STUDY NO, IP(B)(4)

    Patient problems: Insufficient Information

    MAUDE report 18160464 ↗