Myopore® Sutureless Myocardial Pacing Lead 511212Recalls & reported problems

Greatbatch Ltd · Myopore® Bipolar Sutureless Pacing Lead · Class 3 · Implant

All models of Myopore Sutureless Myocardial Pacing Lead (2)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Quick summary

This Greatbatch Myopore sutureless pacing lead is a wire attached to the heart muscle to help it beat. Of its 273 reports, 143 are injury reports, 127 are malfunction reports, and 2 deaths are listed. Many describe infections around the lead, often leading to its removal, and some describe the lead failing to pace the heart. No recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
274
Deaths reported
2
Injuries reported
144
Recalls naming it
0

Summary

The FDA's MAUDE database contains 274 adverse event reports that list this exact device (DI 00821329900228), received between Aug 11, 2015 and Sep 18, 2026 — classified as 2 deaths, 144 injuries, 127 malfunctions.

The most frequently reported specific device problem is “Failure to Capture” (56 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 4 reportsDec 2023: 1 reportsJan 2024: 5 reportsFeb 2024: 0 reportsMar 2024: 3 reportsApr 2024: 0 reportsMay 2024: 5 reportsJun 2024: 2 reportsJul 2024: 2 reportsAug 2024: 1 reportsSep 2024: 7 reportsOct 2024: 4 reportsNov 2024: 4 reportsDec 2024: 1 reportsJan 2025: 0 reportsFeb 2025: 5 reportsMar 2025: 2 reportsApr 2025: 2 reportsMay 2025: 2 reportsJun 2025: 1 reportsJul 2025: 1 reportsAug 2025: 2 reportsSep 2025: 2 reportsOct 2025: 3 reportsNov 2025: 4 reportsDec 2025: 5 reportsJan 2026: 2 reportsFeb 2026: 2 reportsMar 2026: 2 reportsApr 2026: 1 reportsMay 2026: 4 reportsJun 2026: 3 reportsJul 2026: 0 reportsAug 2026: 2 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520267
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem147
  • Failure to Capture56
  • High Capture Threshold42
  • High impedance12
  • Device Dislodged or Dislocated9
  • Insufficient Device Problem Information9
  • Fracture8
  • Low impedance6

Patient problems

  • Unspecified Infection107
  • No Clinical Signs, Symptoms or Conditions71
  • Therapeutic Response, Decreased36
  • Bacterial Infection12
  • Sepsis11
  • No Known Impact Or Consequence To Patient8
  • Erosion6
  • No Information6

Recent adverse event reports

The 25 most recent of 274 reports, in the reporter's own words as published by the FDA.

  • InjurySep 18, 2026Adverse Event Without Identified Device or Use Problem

    Lead was capped.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50818726 ↗
  • InjuryAug 21, 2026Failure to Capture; Fracture; Device Sensing Problem; Impedance Problem

    Failure of epicardial left ventricular lead was reported. Required urgent implant of new leadless pacemaker. Conductor fracture, impedance change with significant sensing and capture issues were reported.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50378511 ↗
  • InjuryAug 3, 2026High Capture Threshold

    High thresholds on epicardial left ventricle lead was reported. Lead was capped. This event is related to 2183787-2026-00050.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50123125 ↗
  • InjuryJun 29, 2026Adverse Event Without Identified Device or Use Problem

    LEAD WAS INFECTED. LEAD WAS IMPLANTED, OUT-OF-SERVICE. THIS EVENT IS RELATED TO 2183787-2026-00045.

    Patient problems: Unspecified Infection

    MAUDE report 25660886 ↗
  • InjuryJun 5, 2026Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THIS IMPLANTABLE LEAD WAS PART OF THE SYSTEM REVISION DUE TO INFECTION. NO ADVERSE PATIENT EFFECTS WERE REPORTED. THE IMPLANTABLE LEAD WAS SURGICALLY ABANDONED.

    Patient problems: Unspecified Infection

    MAUDE report 25405634 ↗
  • InjuryJun 5, 2026Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THIS IMPLANTABLE LEAD WAS PART OF THE SYSTEM REVISION DUE TO INFECTION. NO ADVERSE PATIENT EFFECTS WERE REPORTED. THE IMPLANTABLE LEAD WAS SURGICALLY ABANDONED.

    Patient problems: Unspecified Infection

    MAUDE report 25405630 ↗
  • InjuryMay 28, 2026Adverse Event Without Identified Device or Use Problem

    LEAD WAS EXPLANTED DUE TO INFECTION.

    Patient problems: Unspecified Infection

    MAUDE report 25323588 ↗
  • InjuryMay 15, 2026Adverse Event Without Identified Device or Use Problem

    LEAD WAS CAPPED DUE TO INFECTION AT THE POCKET.

    Patient problems: Unspecified Infection

    MAUDE report 25186214 ↗
  • MalfunctionMay 15, 2026Adverse Event Without Identified Device or Use Problem

    LEAD WAS CAPPED DUE TO OTHER/NON-PRODUCT EXPERIENCE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25185853 ↗
  • InjuryMay 4, 2026Adverse Event Without Identified Device or Use Problem

    LEAD WAS CAPPED DUE TO INFECTION.

    Patient problems: Unspecified Infection

    MAUDE report 25068852 ↗
  • InjuryApr 23, 2026Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THIS LEFT VENTRICULAR (LV) LEAD WAS EXPLANTED AND SUCCESSFULLY DUE TO AN ANOMALY UNRELATED TO THE PERFORMANCE OF THE LEAD. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24974816 ↗
  • MalfunctionMar 18, 2026Failure to Sense; Low impedance

    PATIENT IMPLANTED WITH RV LEAD SUFFERED FROM TWIDDLER'S SYNDROME. THE PHYSICIAN OPTED TO PERFORM A DEVICE REVISION PROCEDURE TO SUTURE THE DEVICE DOWN IN THE POCKET TO PREVENT TWIDDLING. LEAD MEASUREMENTS WERE NOTED TO BE WITHIN NORMAL LIMITS PRIOR TO OPENING THE DEVICE POCKET. THE POCKET WAS THEN OPENED AND THE DEVICE WAS SUTURED TO THE PECTORAL MUSCLE. THE POCKET WAS THEN CLOSED AND THE LEAD WAS RETESTED. THE RV LEAD WAS NO LONGER SENSING IN BIPOLAR CONFIGURATION AND PACING IMPEDANCE MEASUREMENTS WERE LESS THAN 200 OHMS. THRESHOLD MEASUREMENTS WERE NOTED TO BE STABLE, SO SENSING WAS REPROGRAMMED TO UNIPOLAR. IT WAS NOTED THAT THE DEVICE WAS PROGRAMMED TO LEFT VENTRICULAR (LV) ONLY PACING. THIS DEVICE REMAINS IN SERVICE.

    Patient problems: Twiddlers Syndrome

    MAUDE report 24635112 ↗
  • MalfunctionMar 2, 2026Positioning Problem

    LEFT VENTRICULAR (LV) LEAD REVISION SCHEDULED DUE TO FAILED LV PLACEMENT AT IMPLANT 2 DAYS AGO.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24489901 ↗
  • InjuryFeb 11, 2026Adverse Event Without Identified Device or Use Problem

    POCKET INFECTION WAS REPORTED. PATIENT IS ON ANTIBIOTICS.

    Patient problems: Unspecified Infection

    MAUDE report 24318205 ↗
  • InjuryFeb 11, 2026Adverse Event Without Identified Device or Use Problem

    LEAD WAS EXTRACTED DUE TO INFECTION. THIS EVENT IS RELATED TO 2183787-2026-00006.

    Patient problems: Unspecified Infection

    MAUDE report 24317353 ↗
  • InjuryJan 30, 2026Adverse Event Without Identified Device or Use Problem

    LEAD WAS EXTRACTED DUE TO INFECTION. THIS EVENT IS RELATED TO 2183787-2026-00007.

    Patient problems: Unspecified Infection

    MAUDE report 24227063 ↗
  • MalfunctionJan 29, 2026Signal Artifact/Noise; High impedance; Over-Sensing; Pacing Problem

    IT WAS REPORTED THAT THIS CARDIAC RESYNCHRONIZATION THERAPY PACEMAKER (CRT-P) TRIGGERED A LEAD SAFETY SWITCH (LSS) DUE TO PACING IMPEDANCE MEASUREMENTS OUT OF RANGE ON THE RIGHT VENTRICULAR (RV) LEAD. TECHNICAL SERVICES (TS) REVIEWED AND PROVIDED TROUBLESHOOTING OPTIONS. THIS PATIENT WAS SEEN IN CLINIC AND NOISE OVERSENSING WAS NOTED, AS WELL AS PACING INHIBITION GREATER THAN TWO SECONDS. TS STATED THIS IS LIKELY RELATED TO A LEAD ANOMALY. TS SUGGESTED TO HAVE THE PATIENT PERFORMED A PATIENT-INITIATED INTERROGATION (PII) UNTIL SCHEDULE FOR A REPLACEMENT. THIS LEAD REMAINS IN SERVICE. NO ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Asystole

    MAUDE report 24210066 ↗
  • InjuryDec 11, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    LEAD WAS EXPLANTED DUE TO INFECTION.

    Patient problems: Unspecified Infection

    MAUDE report 23783181 ↗
  • MalfunctionDec 11, 2025Failure to Capture; Failure to Capture

    LEAD WAS PLACED A COUPLE WEEKS AGO AND NOW IT HAS NO CAPTURE. LEAD WAS CAPPED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23782926 ↗
  • InjuryDec 3, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    LEAD WAS ABANDONED DUE TO INFECTION. THIS EVENT IS RELATED TO 2183787-2025-00058.

    Patient problems: Unspecified Infection

    MAUDE report 23711119 ↗
  • InjuryDec 3, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    LEAD WAS ABANDONED DUE TO INFECTION. THIS EVENT IS RELATED TO 2183787-2025-00059.

    Patient problems: Unspecified Infection

    MAUDE report 23710805 ↗
  • MalfunctionDec 3, 2025Failure to Capture; Low impedance; High Capture Threshold; Failure to Capture; Low impedance; High Capture Threshold

    LEAD WAS IMPLANTED AND HAD GREAT RESULTS FOR ABOUT 5 DAYS. LEAD WAS FIRMLY STILL IN THE EPICARDIUM AND HAD STARTED TO ENDOTHELISE. THE ENTIRE EPICARDIUM WAS COVERED IN SIGNIFICANT SCAR AND IT WAS SUSPECTED THAT THE LEAD WAS SCREWED INTO SCAR TISSUE. LEAD WAS SURGICALLY ABANDONED AND REPLACED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23710056 ↗
  • InjuryNov 26, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THIS LEFT VENTRICULAR (LV) LEAD WAS PART OF A SYSTEM REVISION DUE TO INFECTION. THERE WERE NO ADDITIONAL ADVERSE PATIENT EFFECTS REPORTED. THE LV LEAD WAS EXPLANTED.

    Patient problems: Unspecified Infection

    MAUDE report 23660684 ↗
  • MalfunctionNov 24, 2025Failure to Capture; Failure to Capture

    LOSS OF CAPTURE WAS NOTED. LEAD WAS CAPPED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23639466 ↗
  • InjuryNov 20, 2025Failure to Capture; Failure to Capture

    IT WAS REPORTED THAT THIS LEFT VENTRICULAR (LV) LEAD EXHIBITED LOSS OF CAPTURE (LOC). SUBSEQUENTLY, IT WAS DECIDED TO CAP THIS LEAD AND REPLACED IT. A NEW LV LEAD WAS IMPLANTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23607542 ↗

Other Permanent Pacemaker Electrode devices

All Permanent Pacemaker Electrode devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page