Skip to content

USA Elite EMRS-24BRecalls & reported problems

Gyrus ACMI, LLC · USA Elite System Metal Resectoscope Sheath, Brown Beak (Use With ETOR-24B Only) 24 Fr, (8 mm) Color Coded Yellow · Class 2

All models of USA Elite (24)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00821925001978), received between Jul 27, 2023 and Nov 29, 2023 — classified as 1 injury, 1 malfunction.

The most frequently reported specific device problem is “Break” (2 reports).

7 other recalls cover devices cleared under the same FDA submission (K890328); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reportsNov 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break2

Patient problems

  • No Clinical Signs, Symptoms or Conditions2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionNov 29, 2023Break; Break

    THE CUSTOMER REPORTED TO OLYMPUS THAT THE NON-CF RESECTOSCOPE METAL BROWN BEAK SHEATH, 24FR HAD A TIP BROKEN. THE ISSUE WAS FOUND DURING REPROCESSING. THERE WERE NO REPORTS OF PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18233935 ↗
  • InjuryJul 27, 2023Break; Break

    THE CUSTOMER REPORTED TO OLYMPUS THE NON-CF RESECTOSCOPE METAL BROWN BEAK SHEATH WAS DAMAGED AND CHIPPED WHEN A FOREIGN OBJECT WAS NOTED ON THE DISPLAY SCREEN DURING A THERAPEUTIC, TRANSURETHRAL RESECTION OF A BLADDER LESION. THE OBJECT WAS FOUND TO BE A FRAGMENT OF THE SHEATH. ANOTHER DEVICE WAS USED TO RETRIEVE THE FRAGMENT AND THE PROCEDURE WAS COMPLETED USING A SIMILAR DEVICE. THIS CAUSED A MINOR DELAY AND A MINOR EXTENSION OF THE GENERAL ANESTHESIA. THERE WERE NO ADDITIONAL REPORTS OF PATIENT IMPACT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17409839 ↗

FDA clearance and classification

Cleared through 510(k) K890328 on Feb 6, 1990 (decision: Substantially Equivalent). Submitted by Circon Video as “Adult Resectoscope”. The FDA review took 379 days. FDA record ↗

The FDA regulates product code HIH (hysteroscope (and accessories)) under 21 CFR 884.1690 as a Class II device. 21 CFR 884.1690 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K890328. One submission often covers many models, so check the product and lot details in each record.

  • Z-3299-2026 · Aug 24, 2026 · Open, Classified
    Olympus M3 Gold Autoclavable Foroblique Telescope 30. Model Number: M3-30A.
  • Z-3300-2026 · Aug 24, 2026 · Open, Classified
    Olympus M3 Gold Autoclavable Lateral Telescope 70. Model Number: M3-70A.
  • Z-2720-2026 · May 5, 2026 · Open, Classified
    Olympus Ellik Evacuator Includes Glass Body, Male Connecting Tubing & Latex Bulb. Model Number: 194.
  • Z-2139-2025 · Jun 18, 2025 · Open, Classified
    Blue Silicone, Reusable Silicone Seal 6 - 12 FR. Model Number: CS-B612. The reusable silicone seals fit over the biopsy port of endoscopes to seal off the working channel. Some
  • Z-2140-2025 · Jun 18, 2025 · Open, Classified
    Green Silicone Seal for Accessories, Reusable Silicone Seal 0 - 7 FR. Model Number: CS-G7. The reusable silicone seals fit over the biopsy port of endoscopes to seal off the work
  • Z-0568-2024 · Oct 2, 2023 · Open, Classified
    ACMI Roller Bar Electrodes bearing incorrect pouch label of ACMI USA Elite System and USA Series Right Angle Cutting Loop Electrode Stabilized, 0.012 Wire 24 Fr (8mm), Model: REF M
  • Z-1952-2018 · Apr 17, 2018 · Terminated
    Gyrus ACMI Reusable Active Cord for Bovie/ValleyLab Generators, Catalog No C650-129A (00821925008700) The cord consists of a single conductor stranded wire terminated with plugs t

Common questions about the USA Elite EMRS-24B

Has the USA Elite EMRS-24B been recalled?

No FDA recall record in our data names this exact device identifier (DI 00821925001978), based on the FDA recall file dated Nov 27, 2026. However, 7 recalls involve devices cleared under the same FDA submission. They may or may not include this model, so check the product, model and lot details in those records.

What problems have been reported with the USA Elite EMRS-24B?

The FDA's MAUDE database lists 2 adverse event reports for this device, received between Jul 27, 2023 and Nov 29, 2023. In those reports, the most common specific device problem is “Break” (2). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the USA Elite EMRS-24B?

None of the reports are classified as deaths, 1 as an injury and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the USA Elite EMRS-24B FDA approved?

It was cleared through 510(k) K890328 on Feb 6, 1990. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Who makes the USA Elite EMRS-24B, and is it still sold?

The FDA's device database lists Gyrus ACMI, LLC as the company responsible for it (brand USA Elite, model EMRS-24B). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Hysteroscope (And Accessories) devices

All Hysteroscope (And Accessories) devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page