Park G03431Recalls & reported problems
Cook Incorporated · Park Blade Septostomy Catheter · Class 2
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00827002034310), received between Dec 17, 2018 and Sep 18, 2024 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Difficult to Open or Close” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Difficult to Open or Close1
- Mechanical Problem1
Patient problems
- Foreign Body In Patient1
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjurySep 18, 2024Difficult to Open or Close; Difficult to Open or Close
AS REPORTED, DURING A PROCEDURE INVOLVING DECOMPRESSION OF THE LEFT ATRIUM, A PARK BLADE SEPTOSTOMY CATHETER¿S BLADE WOULD NOT CLOSE PROPERLY. THE PEDIATRIC PATIENT, WHO WAS ANTI-COAGULATED, HAD MITRAL VALVE REGURGITATION AND WAS ON ECMO (EXTRACORPOREAL MEMBRANE OXYGENATION). ANOTHER MANUFACTURER¿S 8-FRENCH SHEATH WAS USED WITH THE COMPLAINT DEVICE. THE USER TESTED THE BLADE ON THE STERILE TABLE, THROUGH THE OTHER MANUFACTURER¿S SHEATH, PRIOR TO INSERTING THE DEVICE INTO THE PATIENT, TO ENSURE THAT THE BLADE MECHANISM WORKED PROPERLY. A TRANSTHORACIC ECHOCARDIOGRAM (TTE) WAS PERFORMED PRIOR TO CATHETERIZATION, SHOWING THAT THE LEFT ATRIUM WAS SEVERELY DILATED, WITH 91-MILLILITERS OF VOLUME. A TTE PERFORMED DURING THE PROCEDURE NOTED SUBJECTIVE SEVERE DILATION OF THE LEFT ATRIUM. THE INTERATRIAL SEPTUM WAS INTACT PRIOR TO CATHETERIZATION, AND ANOTHER MANUFACTURER¿S TRANSSEPTAL RADIOFREQUENCY WIRE WAS USED PRIOR TO THE PARK BLADE. THE PHYSICIAN SUCCESSFULLY CROSSED THE ATRIAL SEPTUM AND OPENED THE BLADE WITHOUT ISSUE. CONTRAST WAS NOT INJECTED THROUGH THE CATHETER. PER THE PHYSICIAN, IMAGING DURING THE PROCEDURE WAS NOT ¿TO PAR¿ DUE TO THE CONDITION OF THE PATIENT¿S LUNGS. WHEN THE P
Patient problems: Foreign Body In Patient
MAUDE report 20252046 ↗MalfunctionDec 17, 2018Mechanical Problem
IT WAS REPORTED THAT THE BLADE OF THE PARK BLADE SEPTOSTOMY CATHETER WAS NOT COMING OUT CORRECTLY. ANOTHER DEVICE WAS USED TO FINISH THE PROCEDURE. THERE WERE NO INJURIES OR ADDITIONAL PROCEDURES REPORTED.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8172096 ↗
Other CATHETER, SEPTOSTOMY devices
- VersaCross Access Solution VXSK0031Baylis Médicale Cie Inc · Catheter, Septostomy1 recall16 reports
- VersaCross Access Solution VXSK0021Baylis Médicale Cie Inc · Catheter, Septostomy1 recall1 death15 reports
- VersaCross Access Solution VXSK0032Baylis Médicale Cie Inc · Catheter, Septostomy1 recall14 reports
- VersaCross Access Solution VXSK0022Baylis Médicale Cie Inc · Catheter, Septostomy1 recall13 reports
- VersaCross Access Solution VXSK0024Baylis Médicale Cie Inc · Catheter, Septostomy1 recall3 reports
- VersaCross Access Solution VXSK0034Baylis Médicale Cie Inc · Catheter, Septostomy1 recall1 report
- VersaCross Access Solution VXSK0025Baylis Médicale Cie Inc · Catheter, Septostomy1 recall1 report
- NRG Transseptal Needle NRG-E-HF-71-C0Boston Scientific Corporation · Catheter, Septostomy22 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.