Skip to content

Park G03431Recalls & reported problems

Cook Incorporated · Park Blade Septostomy Catheter · Class 2

Adverse event reports
2
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00827002034310), received between Dec 17, 2018 and Sep 18, 2024 — classified as 1 injury, 1 malfunction.

The most frequently reported specific device problem is “Difficult to Open or Close” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 1 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Difficult to Open or Close1
  • Mechanical Problem1

Patient problems

  • Foreign Body In Patient1
  • No Known Impact Or Consequence To Patient1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjurySep 18, 2024Difficult to Open or Close; Difficult to Open or Close

    AS REPORTED, DURING A PROCEDURE INVOLVING DECOMPRESSION OF THE LEFT ATRIUM, A PARK BLADE SEPTOSTOMY CATHETER¿S BLADE WOULD NOT CLOSE PROPERLY. THE PEDIATRIC PATIENT, WHO WAS ANTI-COAGULATED, HAD MITRAL VALVE REGURGITATION AND WAS ON ECMO (EXTRACORPOREAL MEMBRANE OXYGENATION). ANOTHER MANUFACTURER¿S 8-FRENCH SHEATH WAS USED WITH THE COMPLAINT DEVICE. THE USER TESTED THE BLADE ON THE STERILE TABLE, THROUGH THE OTHER MANUFACTURER¿S SHEATH, PRIOR TO INSERTING THE DEVICE INTO THE PATIENT, TO ENSURE THAT THE BLADE MECHANISM WORKED PROPERLY. A TRANSTHORACIC ECHOCARDIOGRAM (TTE) WAS PERFORMED PRIOR TO CATHETERIZATION, SHOWING THAT THE LEFT ATRIUM WAS SEVERELY DILATED, WITH 91-MILLILITERS OF VOLUME. A TTE PERFORMED DURING THE PROCEDURE NOTED SUBJECTIVE SEVERE DILATION OF THE LEFT ATRIUM. THE INTERATRIAL SEPTUM WAS INTACT PRIOR TO CATHETERIZATION, AND ANOTHER MANUFACTURER¿S TRANSSEPTAL RADIOFREQUENCY WIRE WAS USED PRIOR TO THE PARK BLADE. THE PHYSICIAN SUCCESSFULLY CROSSED THE ATRIAL SEPTUM AND OPENED THE BLADE WITHOUT ISSUE. CONTRAST WAS NOT INJECTED THROUGH THE CATHETER. PER THE PHYSICIAN, IMAGING DURING THE PROCEDURE WAS NOT ¿TO PAR¿ DUE TO THE CONDITION OF THE PATIENT¿S LUNGS. WHEN THE P

    Patient problems: Foreign Body In Patient

    MAUDE report 20252046 ↗
  • MalfunctionDec 17, 2018Mechanical Problem

    IT WAS REPORTED THAT THE BLADE OF THE PARK BLADE SEPTOSTOMY CATHETER WAS NOT COMING OUT CORRECTLY. ANOTHER DEVICE WAS USED TO FINISH THE PROCEDURE. THERE WERE NO INJURIES OR ADDITIONAL PROCEDURES REPORTED.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 8172096 ↗

Other CATHETER, SEPTOSTOMY devices

All CATHETER, SEPTOSTOMY devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.