Roadrunner G18153Recalls & reported problems
Cook Incorporated · Roadrunner, Hydrophilic PC Wire guide With 8cm Taper · Class 2
All models of Roadrunner (28)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 6
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 1
Summary
The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00827002181533), received between Sep 14, 2017 and Sep 2, 2025 — classified as 6 malfunctions.
The most frequently reported specific device problem is “Material Separation” (2 reports).
1 FDA recall record name this device's identifier, 1 still open.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Recalls naming this device
- Aug 16, 2022Class IIOpen, Classified
Cook Medical identified that devices from the affected device lots may have a complete breach of the chevron seal of the packaging. Therefore, the sterility of affected devices may be compromised.
Z-1837-2022 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
Most reported problems
Device problems
- Material Separation2
- Break1
- Device Contaminated During Manufacture or Shipping1
- Flaked1
- Scratched Material1
Patient problems
- No Clinical Signs, Symptoms or Conditions4
- No Consequences Or Impact To Patient2
- No Code Available1
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 2, 2025Material Separation; Material Separation
NO ADDITIONAL INFORMATION REGARDING THE PATIENT AND/OR EVENT HAS BEEN RECEIVED SINCE THE PREVIOUS MEDWATCH REPORT WAS SENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22937548 ↗MalfunctionJan 17, 2025Device Contaminated During Manufacture or Shipping; Device Contaminated During Manufacture or Shipping
IT WAS REPORTED THE ROADRUNNER THE FIRM HYDROPHILIC WIRE GUIDE'S STERILIZED PACKAGE CONTAINED A HAIR. THE HAIR WAS FOUND WHEN THE DISTRIBUTOR RECEIVED THE DEVICE. DEVICE DID NOT MAKE PATIENT CONTACT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21178251 ↗MalfunctionNov 14, 2023Break; Break
IT WAS REPORTED THAT THE TIP OF A ROADRUNNER THE FIRM HYDROPHILIC WIRE GUIDE WAS DISCOVERED TO BE BROKEN PRIOR TO PATIENT CONTACT. AS REPORTED, THE PATIENT DID NOT EXPERIENCE ANY ADVERSE EFFECTS OR REQUIRE ANY ADDITIONAL PROCEDURES DUE TO THIS OCCURRENCE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18136057 ↗MalfunctionSep 14, 2021Scratched Material; Scratched Material
AS REPORTED, AFTER REMOVING A ROADRUNNER THE FIRM HYDROPHILIC WIRE GUIDE FROM THE PACKAGE, A SLIGHT SCRATCH ON THE COATING OF THE DEVICE WAS DISCOVERED. THE DEVICE DID NOT MAKE PATIENT CONTACT. THE PROCEDURE WAS COMPLETED USING A NEW PRODUCT. NO SECTION OF THE DEVICE REMAINED INSIDE THE PATIENT'S BODY. THE PATIENT DID NOT REQUIRE ANY ADDITIONAL PROCEDURES DUE TO THIS OCCURRENCE. THERE WERE NO ADVERSE EFFECTS ON THE PATIENT DUE TO THIS OCCURRENCE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12467028 ↗MalfunctionJun 19, 2019Material Separation; Material Separation
ADDITIONAL INFORMATION WAS RECEIVED: IT WAS THE WHITE COATING (POLYMER JACKET) THAT PEELED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8711872 ↗MalfunctionSep 14, 2017Flaked; Flaked
AS REPORTED IN THE VOLUNTARY MEDWATCH REPORT RECEIVED FROM THE USER FACILITY, "DURING URETEROSCOPY PROCEDURE, WHILE REMOVING THE COOK MEDICAL ROADRUNNER HYDROPHILIC PC WIRE, THE PROTECTIVE COATING SHREDDED UPON REMOVAL THRU THE SCOPE. THERE IS A POSSIBILITY THAT THE PROVIDER CAME INTO CONTACT WITH THE EDGE OF THE SCOPE DURING REMOVAL. ALL PIECES WERE REMOVED AND NO HARM TO THE PATIENT." FURTHER PATIENT, DEVICE AND EVENT DETAILS HAVE BEEN REQUESTED FROM THE USER FACILITY, BUT HAVE NOT YET BEEN RECEIVED AT THE TIME OF THIS SUBMISSION.
Patient problems: No Code Available; No Consequences Or Impact To Patient
MAUDE report 6865019 ↗
FDA clearance and classification
The FDA regulates product code OCY (endoscopic guidewire, gastroenterology-urology) under 21 CFR 876.1500 as a Class II device. 21 CFR 876.1500 ↗
Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the Roadrunner G18153
Has the Roadrunner G18153 been recalled?
Yes. 1 FDA recall record names this device's identifier, and it is still open. The recall, Z-1837-2022 (Class II), began on Aug 16, 2022: Cook Medical identified that devices from the affected device lots may have a complete breach of the chevron seal of the packaging. Therefore, the sterility of affected devices may be compromised. If you use this device, follow the manufacturer's notice and your healthcare provider's advice.
What problems have been reported with the Roadrunner G18153?
The FDA's MAUDE database lists 6 adverse event reports for this device, received between Sep 14, 2017 and Sep 2, 2025. In those reports, the most common specific device problems are “Material Separation” (2), “Break” (1) and “Device Contaminated During Manufacture or Shipping” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Roadrunner G18153?
None of the reports are classified as deaths, 0 as injuries and 6 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the Roadrunner G18153 FDA approved?
Devices of this type (product code OCY) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Cook Incorporated.
Who makes the Roadrunner G18153, and is it still sold?
The FDA's device database lists Cook Incorporated as the company responsible for it (brand Roadrunner, model G18153). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Endoscopic guidewire, gastroenterology-urology devices
- HiWire G30474Cook Incorporated · Endoscopic guidewire, gastroenterology-urology81 reports
- Roadrunner G18154Cook Incorporated · Endoscopic guidewire, gastroenterology-urology1 recall18 reports
- Roadrunner G17542Cook Incorporated · Endoscopic guidewire, gastroenterology-urology1 recall9 reports
- Roadrunner G18155Cook Incorporated · Endoscopic guidewire, gastroenterology-urology1 recall3 reports
- Roadrunner G17539Cook Incorporated · Endoscopic guidewire, gastroenterology-urology1 recall2 reports
- Roadrunner G17540Cook Incorporated · Endoscopic guidewire, gastroenterology-urology1 recall0 reports
- Jagwire M00556580Boston Scientific Corporation · Endoscopic guidewire, gastroenterology-urology1 death48 reports
- Acrobat G34266Cook Incorporated · Endoscopic guidewire, gastroenterology-urology44 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026 · each recall links to the FDA recall notice
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page