Roadrunner G22419Recalls & reported problems
Cook Incorporated · Roadrunner Wire Guide · Class 2
All models of Roadrunner (28)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00827002224193), received between Sep 9, 2016 and Sep 9, 2016 — classified as 1 malfunction.
The most frequently reported specific device problem is “Fracture” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Fracture1
- Improper or Incorrect Procedure or Method1
- Off-Label Use1
Patient problems
- Device Embedded In Tissue or Plaque1
- Foreign Body In Patient1
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 9, 2016Fracture; Off-Label Use; Improper or Incorrect Procedure or Method; Fracture; Off-Label Use; Improper or Incorrect Procedure or Method
DURING A RENDEZVOUS PROCEDURE IN THE STOMACH, THE PHYSICIAN USED A COOK ROADRUNNER WIRE GUIDE. THE WIRE GUIDE SHREDDED AFTER BEING PULLED THROUGH A COVIDIEN 22G SHARK CORE FNA/FNB NEEDLE, WHICH IS NOT INDICATED TO BE USED WITH A WIRE GUIDE IN THIS MANNER [OFF LABEL USE]. THE TIP WAS MISSING. THERE WAS NO HARM TO THE PATIENT, HOWEVER THE TIP OF THE WIRE GUIDE REMAINED IN THE PATIENT'S STOMACH. THE DEVICE WAS RECEIVED FOR EVALUATION ON 08/25/2016. TWO (2) DEVICES WERE RECEIVED WITH THE SAME MALFUNCTION (BOTH TIPS DETACHED). THE FOLLOWING CLARIFICATION ON THE SECOND DEVICE WAS RECEIVED FROM THE SALES REPRESENTATIVE: "THIS WIRE WAS USED IN THE EXACT SAME CASE WITH THE EXACT SAME RESULTS." THE FOLLOWING INFORMATION ON THE RETRIEVAL OF THE DETACHED WIRE GUIDE TIPS WAS RECEIVED 08/29/2016 VIA THE SALES REPRESENTATIVE: "THE TIPS WERE ALLOWED TO PASS NATURALLY THROUGH THE PATIENT". ON 10/12/2016, WE RECEIVED A MEDWATCH MW5065042 VIA THE FDA THAT STATED THE FOLLOWING: "PATIENT WAS UNDERGOING AN ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY (ERCP). PHYSICIAN ATTEMPTED MAIN PANCREATIC CANNULATION BUT WAS UNSUCCESSFUL. HE THEN ATTEMPTED AN ENDOSCOPIC ULTRASONOGRAPHY (EUS) GUIDED ERCP, BUT THE
Patient problems: Device Embedded In Tissue or Plaque; Foreign Body In Patient; No Consequences Or Impact To Patient
MAUDE report 5939691 ↗
FDA clearance and classification
The FDA regulates product code OCY (endoscopic guidewire, gastroenterology-urology) under 21 CFR 876.1500 as a Class II device. 21 CFR 876.1500 ↗
Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the Roadrunner G22419
Has the Roadrunner G22419 been recalled?
No FDA recall record in our data names this exact device identifier (DI 00827002224193), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the Roadrunner G22419?
The FDA's MAUDE database lists 1 adverse event report for this device, received on Sep 9, 2016. That report lists device problems “Fracture” (1), “Improper or Incorrect Procedure or Method” (1) and “Off-Label Use” (1); patient problems “Device Embedded In Tissue or Plaque” (1) and “Foreign Body In Patient” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Roadrunner G22419?
None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the Roadrunner G22419 FDA approved?
Devices of this type (product code OCY) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Cook Incorporated.
Who makes the Roadrunner G22419, and is it still sold?
The FDA's device database lists Cook Incorporated as the company responsible for it (brand Roadrunner, model G22419). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Endoscopic guidewire, gastroenterology-urology devices
- HiWire G30474Cook Incorporated · Endoscopic guidewire, gastroenterology-urology81 reports
- Roadrunner G18154Cook Incorporated · Endoscopic guidewire, gastroenterology-urology1 recall18 reports
- Roadrunner G17542Cook Incorporated · Endoscopic guidewire, gastroenterology-urology1 recall9 reports
- Roadrunner G18153Cook Incorporated · Endoscopic guidewire, gastroenterology-urology1 recall6 reports
- Roadrunner G18155Cook Incorporated · Endoscopic guidewire, gastroenterology-urology1 recall3 reports
- Roadrunner G17539Cook Incorporated · Endoscopic guidewire, gastroenterology-urology1 recall2 reports
- Roadrunner G17540Cook Incorporated · Endoscopic guidewire, gastroenterology-urology1 recall0 reports
- Jagwire M00556580Boston Scientific Corporation · Endoscopic guidewire, gastroenterology-urology1 death48 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page