Micropuncture G43872Recalls & reported problems

Cook Incorporated · Micropuncture Introducer Set Silhouette Transitionless With Platinum-Tipped Stainless Steel Wire Guide · Class 2

All models of Micropuncture (39)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
8
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 00827002438729), received between Dec 7, 2016 and Apr 17, 2025 — classified as 3 injuries, 5 malfunctions.

The most frequently reported specific device problem is “Unraveled Material” (5 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 1 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Unraveled Material5
  • Break1
  • Material Frayed1
  • Material Separation1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3
  • No Known Impact Or Consequence To Patient3
  • Device Embedded In Tissue or Plaque1
  • No Code Available1
  • No Consequences Or Impact To Patient1

Recent adverse event reports

The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.

  • InjuryApr 17, 2025Break; Break

    AS REPORTED, DURING AN UNSPECIFIED PROCEDURE, DURING WHICH A MICROPUNCTURE TRANSITIONLESS ACCESS SET WAS USED, THE WIRE ¿SEPARATED AT THE HUB¿ AND PER THE REPORTER, IS BELIEVED TO RESULT IN THE SHEATH ¿BEING DETACHED IN THE LEG¿. FLUOROSCOPY WAS UNABLE TO IDENTIFY A SEPARATED FRAGMENT. THE PATIENT WAS TAKEN TO THE OPERATING ROOM FOR SURGICAL EXPLORATION; HOWEVER, NO FOREIGN BODIES WERE IDENTIFIED. THERE WAS NO EVIDENCE OF A FOREIGN BODY WITHIN THE PATIENT. A CT WITHOUT CONTRAST OF THE RIGHT LEG AND AN ULTRASOUND OF THE ARTERIES IN THE LOWER EXTREMITIES WERE ALSO PERFORMED ON THE DAY OF THE PROCEDURE. ADDITIONAL INFORMATION HAS BEEN REQUESTED TO CLARIFY DETAILS OF THE EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21857393 ↗
  • MalfunctionAug 9, 2022Unraveled Material; Unraveled Material

    AS ORIGINALLY REPORTED TO COOK, PRIOR TO USE DURING AN UNSPECIFIED PROCEDURE, A MICROPUNCTURE TRANSITIONLESS ACCESS SET'S WIRE WAS NOTED TO BE BENT. THE DEVICE WAS NOT USED. UPON RETURN AND EVALUATION OF THE DEVICE, THE WIRE WAS NOTED TO BE UNRAVELED, AND THE SOLDER WAS BROKEN IN MULTIPLE LOCATIONS. THE PATIENT DID NOT REQUIRE ANY ADDITIONAL PROCEDURES DUE TO THIS OCCURRENCE. THERE HAS BEEN NO REPORT OF ANY ADVERSE EFFECTS TO THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15190723 ↗
  • InjuryFeb 12, 2021Material Separation; Material Separation

    ADDITIONAL INFORMATION WAS RECEIVED 19FEB2021 VIA A MEDWATCH 3500A. DURING PLACEMENT OF A PORT-A-CATH IN INTERVENTIONAL RADIOLOGY, THE LEFT INTERNAL JUGULAR VEIN WAS VISUALIZED UNDER FLUOROSCOPY WITH IMAGE DOCUMENTATION OF NEEDLE ENTRY INTO THE LEFT INTERNAL JUGULAR. AN ATTEMPT TO ADVANCE THE GUIDEWIRE CENTRALLY WAS UNSUCCESSFUL AND IN REMOVING THE NEEDLE AND GUIDEWIRE, THE GUIDEWIRE WAS FRACTURED, AND A SEGMENT WAS LODGED IN THE SUBCUTANEOUS TISSUE. ATTEMPTS AT REMOVAL WERE UNSUCCESSFUL AND SURGERY WAS CALLED FOR ASSISTANCE. THE SURGEON WAS ABLE TO EXTEND THE INCISION BY 1-CENTIMETER TO ALLOW FOR DISSECTION AND WAS ABLE TO GRASP THE TISSUE IN WHICH THE GUIDEWIRE WAS EMBEDDED AND REMOVE THE FRAGMENT. THE RADIOLOGIST WAS THEN ABLE TO COMPLETE PORT-A-CATH PLACEMENT WITHOUT FURTHER INCIDENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions; No Code Available

    MAUDE report 11323179 ↗
  • MalfunctionApr 6, 2020Unraveled Material; Unraveled Material

    ADDITIONAL INFORMATION RECEIVED 02APR2020. THE EVENT INVOLVED A PERCUTANEOUS NEPHROSTOMY TUBE. THE WIRE DID NOT ENTER THE PATIENT'S BODY.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 9930113 ↗
  • MalfunctionApr 6, 2020Unraveled Material; Unraveled Material

    ADDITIONAL INFORMATION RECEIVED 02APR2020. THE EVENT INVOLVED A PERCUTANEOUS NEPHROSTOMY TUBE. THE WIRE DID NOT ENTER THE PATIENT'S BODY.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 9929870 ↗
  • MalfunctionJul 24, 2017Unraveled Material

    THE WIRE UNRAVELED UPON REMOVAL FROM THE NEEDLE. A NEW DEVICE WAS OPENED AND USED TO COMPLETE THE PROCEDURE. A SECTION OF THE DEVICE DID NOT REMAIN INSIDE THE PATIENT'S BODY. THE PATIENT DID NOT REQUIRE ANY ADDITIONAL PROCEDURES DUE TO THIS OCCURRENCE. ACCORDING TO THE INITIAL REPORTER, THE PATIENT DID NOT EXPERIENCE ANY ADVERSE EFFECTS DUE TO THIS OCCURRENCE.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 6735820 ↗
  • MalfunctionJul 17, 2017Unraveled Material

    WHEN THEY WERE REMOVING THE INSIDE INTRODUCER AND WIRE FROM THE PATIENT, THE WIRE UNRAVELED. THE CUSTOMER CONFIRMED THAT THEY HAD REMOVED THE NEEDLE BEFORE REMOVING THE WIRE AND INTRODUCER. A SECTION OF THE DEVICE DID NOT REMAIN INSIDE THE PATIENT¿S BODY. THE PATIENT DID NOT REQUIRE ANY ADDITIONAL PROCEDURES DUE TO THIS OCCURRENCE. ACCORDING TO THE INITIAL REPORTER, THE PATIENT DID NOT EXPERIENCE ANY ADVERSE EFFECTS DUE TO THIS OCCURRENCE.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 6717297 ↗
  • InjuryDec 7, 2016Material Frayed; Material Frayed

    IT WAS REPORTED THAT A MICRO-PUNCTURE KIT WAS USED FOR ACCESSING THE RIGHT FEMORAL ARTERY UNDER ULTRASOUND GUIDANCE. IT WAS FURTHER REPORTED THE NEEDLE PUNCTURED THE ARTERY AND THE WIRE WAS THREADED INTO THE ARTERY. THE WIRE WAS EXAMINED UNDER FLOURO AND REVEALED THE WIRE HAD COILED UPON ITSELF AND NEEDED TO BE EXCHANGED FOR A NEW WIRE. THE PHYSICIAN HAD DIFFICULTY REMOVING THE WIRE AND HAD TO FIRST REMOVE THE ACCESS NEEDLE. UPON REMOVAL OF THE WIRE, A VISUAL INSPECTION SHOWED THE WIRE FRAYED. FLURO REVEALED REMNANTS OF THE WIRE IN THE PATIENT ANATOMY. THE ACCESS NEEDLE WAS VISUALLY INSPECTED AND REPORTEDLY ¿APPEARED APPROPRIATE." THE ATTENDING PHYSICIAN CONSULTED WITH TWO VASCULAR SURGEONS AND THE DETERMINATION WAS MADE TO LEAVE THE FRAGMENTS IN THE PATIENTS ANATOMY, THE PATIENT WAS INFORMED OF THE DECISION. NO ADDITIONAL INFORMATION WAS AVAILABLE AT THE TIME OF THIS REPORT.

    Patient problems: Device Embedded In Tissue or Plaque

    MAUDE report 6150866 ↗