Acrobat G44217Recalls & reported problems
Cook Incorporated · Acrobat 2 Calibrated Tip Wire Guide · Class 2
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00827002442177), received between Feb 26, 2016 and Apr 8, 2016 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Peeled/Delaminated” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Peeled/Delaminated3
Patient problems
- No Consequences Or Impact To Patient3
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 8, 2016Peeled/Delaminated; Peeled/Delaminated
ON (B)(6) 2016, WE RECEIVED THE FOLLOWING INFORMATION: DURING TWO (2) ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY (ERCP) PROCEDURES, THE PHYSICIAN USED A COOK ACROBAT CALIBRATED TIP WIRE GUIDE. THE CUSTOMER USED A FUSION IDETOME ON BOTH OCCASIONS. WHEN THE WIRE WAS LOCKED INTO PLACE THEN PASSED INTO THE SPHINCTEROTOME, AND THEN PASSED DOWN ENDOSCOPE, THE TIP OF THE WIRE HAD SLIPPED FORWARD OUT OF THE SPHINCTEROTOME. IT WAS LOCKED PROPERLY AS CHECKED BY THE SENIOR NURSE AFTER NURSE HAD SET IT UP. TWO COOK REPS ALSO PRESENT TO VERIFY THIS. ON 03/14/2016, ONE OF THE TWO DEVICES WAS RECEIVED FOR EVALUATION. THERE WAS COATING DAMAGE PRESENT ON THE DISTAL TIP OF THE DEVICE.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 5562747 ↗MalfunctionMar 28, 2016Peeled/Delaminated; Peeled/Delaminated
DURING AN ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY (ERCP), THE PHYSICIAN USED A COOK ACROBAT CALIBRATED TIP WIRE GUIDE. DURING SEVERAL TRIES TO CANNULATE THE METAL STENT IN A QUITE NARROW ENVIRONMENT IN THE DUODENUM, THE WIRE GUIDE WAS MOVED SEVERAL TIMES BACK AND FORTH FROM THE SPHINCTEROTOME INSIDE THE PATIENT. WHEN TAKING THE DEVICES OUT [OF THE ENDOSCOPE] FOR TRYING ANOTHER SOLUTION [TECHNIQUE], WE SAW THAT THE COATING ON THIS WIRE GUIDE WAS PEELED OFF APPROXIMATELY 10 CM FROM TIP. THE COATING OF THE WIRE GOT STRIPPED OFF BY THE BRIDGE OF THE ENDOSCOPE.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 5530377 ↗MalfunctionFeb 26, 2016Peeled/Delaminated; Peeled/Delaminated
AFTER SPHINCTEROTOMY AND WHEN THE GUIDE WIRE IS IN CDC [COMMON BILE DUCT, CBD], THE DOCTOR PEELED OFF THE SPHINCTEROTOME AND IT WAS VERY HARD TO DO IT [DIFFICULT TO PERFORM ZIP EXCHANGE]. THE GUIDE WIRE PEELED OFF THE DISTAL PART [COATING DAMAGE]. THE PHYSICIAN USED THE LONG TECHNIQUE AND ANOTHER WIRE GUIDE TO FINALIZE THE PROCEDURE.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 5463856 ↗
Other Endoscopic guidewire, gastroenterology-urology devices
- HiWire G30474Cook Incorporated · Endoscopic guidewire, gastroenterology-urology82 reports
- Roadrunner G18154Cook Incorporated · Endoscopic guidewire, gastroenterology-urology1 recall18 reports
- Roadrunner G17542Cook Incorporated · Endoscopic guidewire, gastroenterology-urology1 recall9 reports
- Roadrunner G18153Cook Incorporated · Endoscopic guidewire, gastroenterology-urology1 recall6 reports
- Roadrunner G18155Cook Incorporated · Endoscopic guidewire, gastroenterology-urology1 recall3 reports
- Roadrunner G17539Cook Incorporated · Endoscopic guidewire, gastroenterology-urology1 recall2 reports
- Roadrunner G17540Cook Incorporated · Endoscopic guidewire, gastroenterology-urology1 recall0 reports
- Jagwire M00556580Boston Scientific Corporation · Endoscopic guidewire, gastroenterology-urology1 death49 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.