Flexor G46167Recalls & reported problems
Cook Incorporated · Flexor, Ureteral Access Sheath with AQ, Hydrophilic Coating · Class 2
All models of Flexor (134)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00827002461673), received between Feb 11, 2015 and Jan 7, 2026 — classified as 1 injury, 2 malfunctions.
The most frequently reported specific device problem is “Delamination” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Delamination1
- Device Contamination with Chemical or Other Material1
- Material Separation1
- Peeled/Delaminated1
Patient problems
- Foreign body, removal of1
- No Clinical Signs, Symptoms or Conditions1
- No Patient Involvement1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionJan 7, 2026Peeled/Delaminated
NO ADDITIONAL INFORMATION REGARDING THE PATIENT AND/OR EVENT HAS BEEN RECEIVED SINCE THE PREVIOUS MEDWATCH REPORT WAS SENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23990602 ↗MalfunctionApr 23, 2018Device Contamination with Chemical or Other Material; Device Contamination with Chemical or Other Material
IT WAS REPORTED THAT THE USER RECEIVED THE FLEXOR URETERAL ACCESS SHEATH AND DILATORS WITH A PARTICLE INSIDE IT. THERE WERE NO ADVERSE CONSEQUENCES TO THE PATIENT AS A RESULT OF THIS REPORTED ISSUE. THE DEVICE DID NOT MAKE CONTACT WITH THE PATIENT.
Patient problems: No Patient Involvement
MAUDE report 7451913 ↗InjuryFeb 11, 2015Material Separation; Delamination
WHILE PREFORMING A DUAL APPROACH PCNL, (PERCUTANEOUS NEPHROLITHOTOMY, WITH URETEROSCOPY), A PIECE OF THE COATING SHEARED OFF. THE PHYSICIAN USED GRASPING FORCEPS TO REMOVE THE PIECE. NO HARM TO THE PT AND NO ADD'L PROCEDURES OR INTERVENTION WERE REQUIRED DUE TO THIS OCCURRENCE.
Patient problems: Foreign body, removal of
MAUDE report 4527431 ↗
FDA clearance and classification
The FDA regulates product code FED (endoscopic access overtube, gastroenterology-urology) under 21 CFR 876.1500 as a Class II device. 21 CFR 876.1500 ↗
Devices of this type normally need 510(k) clearance before sale.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the Flexor G46167
Has the Flexor G46167 been recalled?
No FDA recall record in our data names this exact device identifier (DI 00827002461673), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the Flexor G46167?
The FDA's MAUDE database lists 3 adverse event reports for this device, received between Feb 11, 2015 and Jan 7, 2026. In those reports, the most common specific device problems are “Delamination” (1), “Device Contamination with Chemical or Other Material” (1) and “Material Separation” (1); the most common patient problem is “Foreign body, removal of” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Flexor G46167?
None of the reports are classified as deaths, 1 as an injury and 2 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Who makes the Flexor G46167, and is it still sold?
The FDA's device database lists Cook Incorporated as the company responsible for it (brand Flexor, model G46167). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other endoscopic access overtube, gastroenterology-urology devices
- EVIS EXERA II SMALL INTESTINAL VIDEOSCOPE OLYMPUS SIF TYPE Q180Olympus Medical Systems Corp. · endoscopic access overtube, gastroenterology-urology1 recall38 reports
- Trokamed WA2PS20LTROKAMED GmbH · Endoscopic Access Overtube, Gastroenterology-Urology1 recall2 deaths2 reports
- Trokamed WA2PS20STROKAMED GmbH · Endoscopic Access Overtube, Gastroenterology-Urology1 recall2 deaths2 reports
- Trokamed WA2PS18STROKAMED GmbH · Endoscopic Access Overtube, Gastroenterology-Urology1 recall0 reports
- Trokamed WA2PS18LTROKAMED GmbH · Endoscopic Access Overtube, Gastroenterology-Urology1 recall0 reports
- Navigator HD M0062502220Boston Scientific Corporation · endoscopic access overtube, gastroenterology-urology1 death31 reports
- Navigator HD M0062502230Boston Scientific Corporation · endoscopic access overtube, gastroenterology-urology29 reports
- Proxis™ Ureteral Access Sheath 231045C. R. Bard, Inc. · endoscopic access overtube, gastroenterology-urology22 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.