Micropuncture Silhouette G53578Recalls & reported problems

Cook Incorporated · Micropuncture Introducer Set Silhouette Transitionless Design with Nitinol Wire Guide and EchoTip Needle · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00827002535787), received between Dec 4, 2024 and Dec 4, 2024 — classified as 1 injury.

The most frequently reported specific device problem is “Unraveled Material” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 1 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Unraveled Material1

Patient problems

  • Hematoma1
  • Reduced Blood Flow1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryDec 4, 2024Unraveled Material; Unraveled Material

    AS REPORTED, DURING PLACEMENT OF A PERCUTANEOUS CENTRAL LINE IN THE LEFT FEMORAL VEIN, A MICROPUNCTURE TRANSITIONLESS ACCESS SET¿S WIRE UNRAVELED UPON REMOVAL. ULTRASOUND GUIDED ACCESS WAS OBTAINED IN THE LEFT FEMORAL VEIN, AND BLOOD RETURN WAS NOTED UPON INSERTION OF THE ACCESS NEEDLE, PRIOR TO INSERTION AND ADVANCEMENT OF THE WIRE GUIDE. THE ACCESS SITE WAS REPORTEDLY NORMAL, AND NO PRIOR ATTEMPTS HAD BEEN MADE TO OBTAIN VASCULAR ACCESS AT THE SITE. THE USER ATTEMPTED TO REMOVE THE WIRE THROUGH THE ENTRY/ACCESS NEEDLE, AND RESISTANCE WAS ENCOUNTERED UPON REMOVAL OF THE ¿LAST PART¿ OF THE WIRE, AT WHICH POINT THE MIDDLE SECTION OF THE WIRE UNRAVELED AND BECAME STUCK. PER THE REPORTER, THE WIRE WAS ABLE TO BE REMOVED MANUALLY THROUGH THE ENTRY NEEDLE, WITH THE END OF THE WIRE INTACT. A NEW WIRE WAS USED TO SUCCESSFULLY COMPLETE THE PROCEDURE. REPORTEDLY, THE PATIENT DEVELOPED A HEMATOMA AROUND THE ACCESS SITE BECAUSE OF THE EVENT, WITH SUBSEQUENT DISCOLORATION OF THE LEG. DIRECT PRESSURE WAS APPLIED FOR ¿SOME TIME¿, THE LIMB WAS ELEVATED, AND WARM COMPRESSES WERE APPLIED. EXTRA CLINICAL MONITORING WAS REQUIRED, INCLUDING USE OF ULTRASOUND AND DOPPLER. A SECTION OF THE DEVICE DID NO

    Patient problems: Hematoma; Reduced Blood Flow

    MAUDE report 20846582 ↗