Valor® 415101125RRecalls & reported problems
Wright Medical Technology, Inc. · Class 2 · Implant
All models of VALOR (25)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00840420125613), received between Dec 4, 2024 and Dec 4, 2024 — classified as 1 malfunction.
The most frequently reported specific device problem is “Device Difficult to Setup or Prepare” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Device Difficult to Setup or Prepare1
- Mechanical Jam1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 4, 2024Device Difficult to Setup or Prepare; Mechanical Jam; Device Difficult to Setup or Prepare; Mechanical Jam
AS REPORTED: "THE INTERNAL COMPRESSION SCREW WOULD NOT ENGAGE INTO THE CALC COMPRESSION SCREW AND WOULD NOT BACK OUT OF THE NAIL. THE INTERNAL COMPRESSION SCREW COLD WELDED INSIDE THE NAIL. THE TARGETING GUIDE WAS REMOVED FROM THE NAIL TO REMOVE THE INTERNAL COMPRESSION SCREW BUT WERE UNABLE TO EITHER PROGRESS OR REMOVE THE INTERNAL COMPRESSION SCREW. DEVICE WAS STILL ABLE TO ACHIEVE DESIRED FUSION. WE WERE NOT ABLE TO UTILIZE THE INTERNAL COMPRESSION OF THIS PRODUCT. THE APPOSITION OF THE ANKLE JOINT HAD OBTAINED ADEQUATE FUSION FROM THE JOINT DEBRIDEMENT. THE SURGEON PREFERRED ADDITIONAL FUSION WITH THE INTERNAL COMPRESSION WHICH WE WERE UNABLE TO UTILIZE. THE INTERNAL COMPRESSION SCREW WAS LEFT COLD WELDED IN THE PLANTAR/BOTTOM ASPECT OF THE NAIL." IT WAS ADDITIONALLY REPORTED THAT THERE WAS A 35 MINUTE SURGICAL DELAY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20848801 ↗
Other Screw, fixation, bone devices
- NA 03.043.029Synthes GmbH · Screw, fixation, bone503 reports
- OSTEORAPTOR 72201995Smith & Nephew, Inc. · Screw, fixation, bone253 reports
- Control 360 SK12Treace Medical Concepts, Inc. · Screw, Fixation, Bone195 reports
- HEALIX PEEK ORTHOCORD 222205Medos International Sàrl · Screw, fixation, bone186 reports
- PRECICE® Bone Transport System STP3.5-350Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-400Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-300Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-200Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page