EVOLVE ORTHOLOC 4953105LRecalls & reported problems

Wright Medical Technology, Inc. · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00840420125798), received between Feb 17, 2026 and Feb 17, 2026 — classified as 1 injury.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Necrosis1
  • Pain1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryFeb 17, 2026Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT, THE PATIENT UNDERWENT A LEFT RADIAL HEAD REPLACEMENT FOR FRACTURE, APPROX. 2 AND HALF YEARS AGO, USING THE TORNIER MOPYC SYSTEM. PATIENT HAD PRESENTED TO THE SURGEON WITH PAIN, OVER LAST 4-6 MONTHS. ON X-RAY, IT SHOWED THE PROSTHETIC PYROCARBON HEAD RUBBING AGAINST A DISTAL HUMERAL PLATE, ALSO INSITU (IMPLANTED FOR AN ASSOCIATED FRACTURE OF THE DISTAL HUMERUS). DURING SURGERY, LARGE AMOUNTS OF BLACK COLOURED TISSUE WERE NOTED, AND AN EXTENSIVE DEBRIDEMENT AND LAVAGE WAS PERFORMED. MULTIPLE TISSUE SAMPLES TAKEN. THE ORIGINAL MOPYC STEM WAS FOUND TO BE SOLID AND THEREFORE LEFT INSITU. THE PRIMARY MOPYC NECK AND HEAD WAS REMOVED (WITHOUT DIFFICULTY) AND REPLACED WITH NEW PROSTHESIS. THE DISTAL HUMERAL PLATE, WHICH WAS RUBBING AGAINST THE PYC HEAD, WAS ALSO REMOVED (THE DISTAL HUMERAL FRACTURE WAS UNITED). THE ELBOW JOINT WAS FOUND TO BE STABLE ON REDUCTION. WOUND CLOSED.

    Patient problems: Necrosis; Pain

    MAUDE report 24365418 ↗

Other PLATE, FIXATION, BONE devices