INBONE 200166Recalls & reported problems
Wright Medical Technology, Inc. · Cannula Foot, Bottom · Class 1
All models of INBONE (56)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00840420196224), received between Dec 17, 2025 and Dec 17, 2025 — classified as 1 malfunction.
The most frequently reported specific device problem is “Mechanical Jam” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Mechanical Jam1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 17, 2025Mechanical Jam; Mechanical Jam
IT WAS REPORTED THAT "REFERENCE 200134S (THE STERILE VERSION OF THE NON-STERILE BURR 200134 INCLUDED IN THE INSTRUMENT SET) APPEARS TO BE SLIGHTLY OVERSIZED AT THE DISTAL END COMPARED TO THE CANNULA IT SHOULD PASS THROUGH, REFERENCE 200166. ATTACHED IS AN EXPLANATORY VIDEO: THE FIRST BURR IS THE STERILE ONE (REF 200134S), WHICH GETS STUCK IN THE CANNULA, WHILE THE SECOND IS THE NON-STERILE BURR (REF 200134), WHICH SLIDES THROUGH THE CANNULA WITHOUT JAMMING." THIS EVENT WAS IDENTIFIED DURING A PRIMARY SURGERY AND RESULTED IN NO ADVERSE CONSEQUENCES TO THE PATIENT OR SURGICAL DELAY. THE DEVICE IS NOT AVAILABLE FOR RETURN.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23830118 ↗
Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page