KARMA 75311-095Recalls & reported problems

Spinal Elements, Inc. · DRILL CARTRIDGE - .095 SHAFT · Class 1

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00840606158237), received between Oct 4, 2023 and May 11, 2026 — classified as 3 malfunctions.

The most frequently reported specific device problem is “Fracture” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 1 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 1 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fracture2
  • Mechanical Problem2
  • Unraveled Material1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2
  • Perforation1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 11, 2026Unraveled Material

    DURING FACET BONE PREPARATION FOR A FACET STABILIZATION FOR SPINAL FUSION, THE CANTED COIL OF THE DRILL UNWOUND AND MADE THE DRILL UNFUNCTIONAL. BACKUP DRILL WAS NOT AVAILABLE AND DIRECT DECOMPRESSION OF THE NERVE ROOT WAS PERFORMED AND THE FIXATION AT THAT LEVEL WAS ABANDONED. THOUGH THE SURGERY WAS COMPLETED, THE DEVICE COULD NOT BE USED AS A RESULT OF THE MALFUNCTION. THERE WAS A PARTIAL DECORTICATION OF THE BONE AS A RESULT OF ATTEMPTING THIS PROCEDURE. PATIENT IS ASYMPTOMATIC.

    Patient problems: Perforation

    MAUDE report 25143334 ↗
  • MalfunctionDec 15, 2023Fracture; Mechanical Problem; Fracture; Mechanical Problem

    REPORTEDLY DURING DECORTICATION OF LAMINA AT L4-S1, 2 OUT 5 ORTHOPEDIC DRILL TIP FRACTURED OFF INSIDE THE LAMINA. SURGEON WAS UNSUCCESSFUL AT RETRIEVING TWO TIPS. HE ELECTED TO LEAVE THE DEVICE TIPS IN PLACE. HE SELECTED A DIFFERENT TRAJECTORY AROUND IT TO COMPLETE THE SPINAL FUSION CASE. BILATERAL POSTERIOR FIXATION WAS ACHIEVED. REPORTEDLY THE YOUNG PATIENT HAD VERY DENSE POSTERIOR BONE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18340770 ↗
  • MalfunctionOct 4, 2023Fracture; Mechanical Problem; Fracture; Mechanical Problem

    REPORTEDLY DURING DECORTICATION OF LAMINA AT L4-L5, THE ORTHOPEDIC DRILL TIP FRACTURED OFF INSIDE THE LAMINA. SURGEON WAS UNSUCCESSFUL AT RETRIEVING THE TIP. HE ELECTED TO LEAVE THE DEVICE TIP IN PLACE. HE SELECTED A DIFFERENT TRAJECTORY AROUND IT TO COMPLETE THE SPINAL FUSION CASE. BILATERAL POSTERIOR FIXATION WAS ACHIEVED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17871175 ↗