RIBFIX BLU SYSTEM 76-2410 (UDI 00841036184209)Recalls & reported problems
Biomet Microfixation, Inc · Class 2
All models of RIBFIX BLU SYSTEM (19)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 4
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00841036184209), received between Feb 28, 2020 and Jan 5, 2021 — classified as 4 injuries.
The most frequently reported specific device problem is “Fracture” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Fracture3
- Migration or Expulsion of Device1
Patient problems
- Discomfort2
- Bone Fracture(s)1
- Failure of Implant1
- No Clinical Signs, Symptoms or Conditions1
- No Known Impact Or Consequence To Patient1
- Pain1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
InjuryJan 5, 2021Fracture; Fracture
NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.
Patient problems: Discomfort; Pain
MAUDE report 11121474 ↗InjuryNov 2, 2020Fracture; Fracture
NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.
Patient problems: No Clinical Signs, Symptoms or Conditions; No Known Impact Or Consequence To Patient
MAUDE report 10771719 ↗InjuryOct 16, 2020Migration or Expulsion of Device; Migration or Expulsion of Device
IT WAS REPORTED THE PATIENT UNDERWENT A REVISION TO REMOVE RIB PLATES TWO (2) WEEKS FOLLOWING IMPLANTATION DUE TO LOOSENING AND DISCOMFORT. TEN (10) DAYS FOLLOWING IMPLANTATION, THE PATIENT REPORTED DISCOMFORT. TWO (2) WEEKS FOLLOWING IMPLANTATION, AN X-RAY REVEALED TWO PLATES WITH THE SCREWS HAD COMPLETELY POPPED OFF. THE PLATES WERE NOT REPLACED. NO ADDITIONAL PATIENT CONSEQUENCES HAVE BEEN REPORTED.
Patient problems: Discomfort; Failure of Implant
MAUDE report 10692154 ↗InjuryFeb 28, 2020Fracture; Fracture
IT WAS REPORTED THAT TWO RIB PLATES FRACTURED POST-OPERATIVELY. AN OPEN REDUCTION AND INTERNAL FIXATION WAS PERFORMED IN WHICH RIBS FIVE, SIX, SEVEN AND NINE WERE PLATED ON THE RIGHT SIDE. AT A LATER UNSPECIFIED DATE, AN X-RAY REVEALED THAT THE PLATES ON RIBS SEVEN AND EIGHT WERE FRACTURED. A REVISION OCCURRED AT A LATER UNSPECIFIED DATE TO REMOVE THE FRACTURED IMPLANTS. NO ADDITIONAL PATIENT CONSEQUENCES WERE REPORTED.
Patient problems: Bone Fracture(s)
MAUDE report 9772286 ↗
FDA clearance and classification
Cleared through Special 510(k) K162974 on Dec 9, 2016 (decision: Substantially Equivalent). Submitted by Biomet Microfixation as “Biomet Microfixation RibFix Blu Thoracic Fixation System”. The FDA review took 45 days. FDA record ↗
Cleared through 510(k) K152253 on Mar 24, 2016 (decision: Substantially Equivalent). Submitted by Biomet Microfixation as “Biomet Microfixation RibFix Blu Thoracic Fixation System”. The FDA review took 227 days. FDA record ↗
Cleared through Special 510(k) K151173 on May 26, 2015 (decision: Substantially Equivalent). Submitted by Biomet Microfixation as “Biomet Microfixation RibFix Blu Thoracic Fixation System”. The FDA review took 25 days. FDA record ↗
…and 1 more FDA submissions listed for this device.
The FDA regulates product code HRS (plate, fixation, bone) under 21 CFR 888.3030 as a Class II device. 21 CFR 888.3030 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the RIBFIX BLU SYSTEM 76-2410
Has the RIBFIX BLU SYSTEM 76-2410 been recalled?
No FDA recall record in our data names this exact device identifier (DI 00841036184209), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the RIBFIX BLU SYSTEM 76-2410?
The FDA's MAUDE database lists 4 adverse event reports for this device, received between Feb 28, 2020 and Jan 5, 2021. In those reports, the most common specific device problems are “Fracture” (3) and “Migration or Expulsion of Device” (1); the most common patient problems are “Discomfort” (2), “Bone Fracture(s)” (1) and “Failure of Implant” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the RIBFIX BLU SYSTEM 76-2410?
None of the reports are classified as deaths, 4 as injuries and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the RIBFIX BLU SYSTEM 76-2410 FDA approved?
It was cleared through 510(k) K142823 on Feb 25, 2015; its record lists 4 FDA submissions in total. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Who makes the RIBFIX BLU SYSTEM 76-2410, and is it still sold?
The FDA's device database lists Biomet Microfixation, Inc as the company responsible for it (brand RIBFIX BLU SYSTEM, model 76-2410). Its record shows it as no longer in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other PLATE, FIXATION, BONE devices
- Lapiplasty System 2 SK14Treace Medical Concepts, Inc. · Plate, Fixation, Bone260 reports
- PRECICE® Plating System LP4.5-PRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls6 reports
- PRECICE® Plating System LP4.5-MLT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls5 reports
- PRECICE® Plating System LP4.5-PLF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-MRT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-DRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls1 report
- PRECICE® Plating System LP4.5-PLF40Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
- PRECICE® Plating System LP4.5-PRT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page