PediLoc Fragment System 00-1005-2108Recalls & reported problems
Orthopediatrics Corp. · 2.7mm Locking Compression Plate, 8 Hole · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00841132104835), received between Oct 6, 2024 and Oct 10, 2024 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Material Deformation” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Material Deformation2
Patient problems
- Failure of Implant2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 10, 2024Material Deformation; Material Deformation
PLATE WAS IN INSERTED FOR FOREARM FRACTURE. AT 4 WEEKS CAST WAS REMOVED. TWO WEEKS LATER PATIENT CAME TO CLINIC EXPERIENCING PAIN AFTER PERFORMING PUSHUPS. PLATE ON RADIUS WAS FOUND TO BE BENT. REVISION WAS PERFORMED. PLATED WAS UPSIZED TO 3.5 LOCKING COMPRESSION PLATE.
Patient problems: Failure of Implant
MAUDE report 20424925 ↗MalfunctionOct 6, 2024Material Deformation; Material Deformation
PLATE WAS IN INSERTED FOR FOREARM FRACTURE. AT 4 WEEKS CAST WAS REMOVED. TWO WEEKS LATER PATIENT CAME TO CLINIC EXPERIENCING PAIN AFTER PERFORMING PUSHUPS. PLATE ON RADIUS WAS FOUND TO BE BENT. REVISION WAS PERFORMED. PLATED WAS UPSIZED TO 3.5 LOCKING COMPRESSION PLATE.
Patient problems: Failure of Implant
MAUDE report 20380231 ↗
Other PLATE, FIXATION, BONE devices
- Lapiplasty System 2 SK14Treace Medical Concepts, Inc. · Plate, Fixation, Bone260 reports
- PRECICE® Plating System LP4.5-PRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls6 reports
- PRECICE® Plating System LP4.5-MLT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls5 reports
- PRECICE® Plating System LP4.5-MRT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-PLF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-DRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls1 report
- PRECICE® Plating System LP4.5-MLT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
- PRECICE® Plating System LP4.5-MRT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page