APEX Knee System KR-46000Recalls & reported problems
Omni Life Science, Inc. · Modular Tibia Augment Bolt Driver · Class 1
All models of APEX Knee System (30)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00841690117841), received between Nov 14, 2024 and Nov 14, 2024 — classified as 1 injury.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Appropriate Device Problem Term/Code Not Available1
Patient problems
- Foreign Body In Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryNov 14, 2024Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
THE COMPLAINT INVOLVED A PATIENT WHO UNDERWENT A KNEE SURGERY ON (B)(6) 2024. DOCTOR WAS DRILLING THE TIBIA CANAL WITH A BOSS REAMER. IT WAS IDENTIFIED BY THE REP ATTENDING THE SURGERY TO THE SURGEON THAT A SMALL PART OF THE REAMER WAS MISSING. THE SCRUB NURSE SEARCHED FOR THE DEVICE AND COULD NOT FIND IT. THE SURGEON STATED THAT IF IT IS IN THE TIBIAL HE IS NOT PREPARED TO REMOVE THE TIBIAL REVISION IMPLANT AS IT WOULD BE MORE DETRIMENTAL TO THE PATIENT. THAT THEY WOULD X-RAY POST OPERATIVELY IF NOT FOUND. SUBSEQUENT TO SURGERY A POST OP X-RAY WAS PERFORMED IN RECOVERY ROOM IDENTIFYING THAT THE INSTRUMENT IS IN THE TIBIAL SHAFT - DISTAL TO THE TIBIAL STEM AND NOT IN CONTACT AS SURROUNDED BY PALACOS R ANTIBIOTIC CEMENT. THIS HAD BEEN IDENTIFIED TO THE SCRUB AT THE START OF THE CASE, WHICH IS WHY A COUNT OF THIS ITEM COMMENCED PRIOR TO CLOSING THE SURGICAL WOUND. ALLOWING THE SURGEON TO INTERVENE IF HE DEEMED APPROPRIATE.
Patient problems: Foreign Body In Patient
MAUDE report 20692307 ↗
Other Orthopedic manual surgical instrument devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page