Hook Plates WHV-6Recalls & reported problems
Trimed, INC. · Volar Wrist Hook Plate, 6-Hole · Class 2 · Implant
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00842188101007), received between Mar 13, 2026 and Mar 13, 2026 — classified as 1 malfunction.
The most frequently reported specific device problem is “Use of Device Problem” (1 report).
1 other recall cover devices cleared under the same FDA submission (K951302); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Use of Device Problem1
Patient problems
- Oversedation1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 13, 2026Use of Device Problem
SALES REP REPORTED ON (B)(6) 2026 THAT THE SURGEON ATTACHED A 6-HOLE VOLAR HOOK PLATE TO THE RADIUS WITH A SINGLE 2.3 TORX SCREW THROUGH THE SLOT IN THE PLATE. ATTENTION WAS THEN DIRECTED TO THE DORSAL SIDE OF THE RADIUS, WHERE A 6-HOLE DORSAL HOOK PLATE WAS ATTACHED WITH A 2.3 TORX SCREW. THIS SCREW WAS INSERTED UNTIL IT PROTRUDED ON THE VOLAR ASPECT OF THE RADIUS AND IMPACTED THE EMPLACED VOLAR HOOK PLATE. THIS IMPACTION FORCED THE VOLAR HOOK PLATE OFF THE BONE, ACTING AS A LEVER AROUND THE HEAD OF THE SCREW AFFIXING IT IN PLACE, AND PUSHING IT OVER AND OFF THE SCREW AND DETACHING THE DISTAL HOOKS FROM BONE. THE VOLAR HOOK PLATE REQUIRED REMOVAL FROM THE SURGICAL SITE AND COULD NOT BE REINSTALLED OR REPLACED DUE TO THE COMMINUTION OF THE BONE AROUND THE INSERTION SITE AND SUBSEQUENT INSTABILITY ASSOCIATED WITH THE FORCED REMOVAL OF THE PLATE TINES. THE REMAINING VOLAR SCREW WAS THEN PROMINENT AND REQUIRED REMOVAL; THIS POSED SOME DIFFICULTY FOR THE SURGEON AS SHE STRUGGLED TO GET THE SCREWDRIVER TO SEAT INTO THE HEAD OF THE SCREW. THE HEAD OF THE SCREW MAY HAVE BEEN BENT UP WHILE PASSING THROUGH THE SLOT IN THE PLATE; THE SLOT IN THE PLATE APPEARS TO HAVE BEEN WIDENED AT THE POIN
Patient problems: Oversedation
MAUDE report 24591375 ↗
FDA clearance and classification
Cleared through 510(k) K951302 on May 5, 1995 (decision: Substantially Equivalent). Submitted by Medpac as “Small Fragment Plates And Screws”. The FDA review took 44 days. FDA record ↗
The FDA regulates product code HRS (plate, fixation, bone) under 21 CFR 888.3030 as a Class II device. 21 CFR 888.3030 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Recalls under the same FDA submission
These recalls involve devices cleared under K951302. One submission often covers many models, so check the product and lot details in each record.
- Z-0118-2020 · Aug 24, 2018 · TerminatedTriMed Dorsal Wrist Hook Plate, Dorsal, 4-Hole, REF WHD-4, contained in a tray, insert, or poly package containing varying amounts, Nonsterile, Single Use Only, Rx. The firm name
Common questions about the Hook Plates WHV-6
Has the Hook Plates WHV-6 been recalled?
No FDA recall record in our data names this exact device identifier (DI 00842188101007), based on the FDA recall file dated Nov 27, 2026. However, 1 recall involves devices cleared under the same FDA submission. It may or may not include this model, so check the product, model and lot details in that record.
What problems have been reported with the Hook Plates WHV-6?
The FDA's MAUDE database lists 1 adverse event report for this device, received on Mar 13, 2026. That report lists device problem “Use of Device Problem” (1); patient problem “Oversedation” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Hook Plates WHV-6?
None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the Hook Plates WHV-6 FDA approved?
It was cleared through 510(k) K951302 on May 5, 1995. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Is the Hook Plates WHV-6 MRI safe?
According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.
Who makes the Hook Plates WHV-6, and is it still sold?
The FDA's device database lists Trimed, INC. as the company responsible for it (brand Hook Plates, model WHV-6). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Plate, fixation, bone devices
- Lapiplasty System 2 SK14Treace Medical Concepts, Inc. · Plate, Fixation, Bone260 reports
- PRECICE® Plating System LP4.5-PRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls6 reports
- PRECICE® Plating System LP4.5-MLT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls5 reports
- PRECICE® Plating System LP4.5-PLF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-MRT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-DRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls1 report
- PRECICE® Plating System LP4.5-PLF40Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
- PRECICE® Plating System LP4.5-PRT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.