Skip to content

BELLATEK® ENCODE® EHA554Recalls & reported problems

ZimVie US Corp LLC · BELLATEK® ENCODE® HEALING ABUTMENT 5MM(D) X 5.6MM(P) X 4MM(H) · Class 2 · Implant

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00844868003083), received between Sep 19, 2025 and Sep 19, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Positioning Failure” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 1 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Positioning Failure1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 19, 2025Positioning Failure; Positioning Failure

    IT WAS REPORTED THAT AFTER IMPLANTING THE IMPLANT, WE ATTEMPTED TO FIT THE ENCODE HEALING ABUTMENT FOR THE FIRST TIME, BUT IT WOULD NOT SEAT AND FLOATED. THE SALES REPRESENTATIVE BROUGHT TWO (2) LOANER IMPLANTS TO THE CLINIC AND ATTEMPTED TO FIT THE HEALING ABUTMENT, BUT IT SIMILARLY FLOATED AND COULD NOT BE FITTED. A REPLACEMENT HEALING ABUTMENT IS SCHEDULED FOR USE SHORTLY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23095321 ↗

Other ABUTMENT, IMPLANT, DENTAL, ENDOSSEOUS devices

All ABUTMENT, IMPLANT, DENTAL, ENDOSSEOUS devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page