Synthes GmbH · 3 mm Fluted Ball, 15 cm. Use with MA-15 Bearing Sleeves. · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
5
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00845384004554), received between Nov 19, 2020 and Jan 8, 2026 — classified as 5 malfunctions.

The most frequently reported specific device problem is “Material Fragmentation” (3 reports).

31 other recalls cover devices cleared under the same FDA submission (K042783); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 1 reportsAug 2024: 0 reportsSep 2024: 1 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 1 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Material Fragmentation3
  • Dull, Blunt1
  • Excessive Heating1
  • Separation Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions4
  • No Consequences Or Impact To Patient1

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJan 8, 2026Material Fragmentation

    IT WAS REPORTED THAT DURING THE DEMO, THE 3MM FLUTED BALL, 15CM BURR DEVICE WAS BROKEN OFF. NO ADDITIONAL INFORMATION COULD BE PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24013150 ↗
  • MalfunctionSep 17, 2024Material Fragmentation; Material Fragmentation

    IT WAS REPORTED FROM COLOMBIA THAT DURING AN UNSPECIFIED SURGICAL PROCEDURE, IT WAS DISCOVERED THAT THE HEAD OF THE BURR DEVICE FRACTURED WHILE THE SURGEON WAS DRILLING. IT WAS NOT REPORTED IF THERE WERE ANY DELAYS IN THE SURGICAL PROCEDURE OR IF A SPARE DEVICE WAS AVAILABLE FOR USE. THERE WAS PATIENT INVOLVEMENT REPORTED. THERE WERE NO REPORTS OF INJURIES, MEDICAL INTERVENTION OR PROLONGED HOSPITALIZATION. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL MEDWATCH REPORT WILL BE SUBMITTED ACCORDINGLY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20236909 ↗
  • MalfunctionJul 5, 2024Dull, Blunt; Dull, Blunt

    IT WAS REPORTED FROM FRANCE THAT DURING A TUMOR RESECTION PROCEDURE, IT WAS OBSERVED THAT THE FLUTED BALL DEVICE DID NOT CUT WITH ENOUGH FORCE. THERE WERE NO DELAYS IN THE SURGICAL PROCEDURE AS AN IDENTICAL SPARE DEVICE WAS AVAILABLE FOR USE. THERE WAS PATIENT INVOLVEMENT. THERE WERE NO INJURIES, MEDICAL INTERVENTION OR PROLONGED HOSPITALIZATION. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL MEDWATCH WILL BE SUBMITTED ACCORDINGLY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19679545 ↗
  • MalfunctionApr 22, 2021Material Fragmentation; Separation Problem; Material Fragmentation; Separation Problem

    IT WAS REPORTED FROM (B)(6) THAT THE MINIMAL ACCESS ATTACHMENT DEVICE EXHIBITED PHYSICAL DAMAGE. UPON RECEIPT OF THE DEVICE BY THE MANUFACTURER, IT WAS DISCOVERED THAT A FRAGMENT OF THE CUTTER DEVICE WAS STUCK IN THE ATTACHMENT DEVICE. IT WAS NOT REPORTED IF THE DEVICE WAS USED IN SURGERY, OR IF THERE WAS PATIENT INVOLVEMENT. IT WAS NOT REPORTED IF THERE WERE ANY DELAYS IN THE SURGICAL PROCEDURE, OR IF A SPARE DEVICE WAS AVAILABLE FOR USE. IT WAS NOT REPORTED IF THERE WERE ANY INJURIES, MEDICAL INTERVENTION OR PROLONGED HOSPITALIZATION. THE DATE OF EVENT WAS UNKNOWN BUT WAS KNOWN TO HAVE OCCURRED IN 2020. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL MEDWATCH WILL BE SUBMITTED ACCORDINGLY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11711795 ↗
  • MalfunctionNov 19, 2020Excessive Heating; Excessive Heating

    IT WAS REPORTED FROM (B)(6) THAT DURING AN UNSPECIFIED SURGICAL PROCEDURE IT WAS OBSERVED THAT WHEN THE NEW CUTTER DEVICE WAS PASSED TO THE TABLE WITH AN ATTACHMENT DEVICE, THE CUTTER DEVICE REHEATED. IT WAS REPORTED THAT THERE WAS NO DELAY IN THE PROCEDURE DUE TO THE EVENT. IT WAS NOT REPORTED IF THERE WAS A SPARE DEVICE AVAILABLE FOR USE. THERE WAS PATIENT INVOLVEMENT REPORTED. THERE WERE NO REPORTS OF INJURIES, MEDICAL INTERVENTION, OR PROLONGED HOSPITALIZATION. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL MEDWATCH WILL BE SUBMITTED ACCORDINGLY.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10871015 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K042783. One submission often covers many models, so check the product and lot details in each record.

  • Z-2003-2017 · Oct 6, 2016 · Terminated
    Bearing Sleeve, 10CM Curved Product Usage: Pneumatic system
  • Z-2005-2017 · Oct 6, 2016 · Terminated
    Bearing Sleeve, 15CM Curved Product Usage: Pneumatic system
  • Z-2004-2017 · Oct 6, 2016 · Terminated
    Bearing Sleeve, 10CM Straight Product Usage: Pneumatic system
  • Z-2007-2017 · Oct 6, 2016 · Terminated
    Bearing Sleeve, 15CM Straight Taper Product Usage: Pneumatic system
  • Z-2009-2017 · Oct 6, 2016 · Terminated
    Minimal Access Attachment Product Usage: Pneumatic system
  • Z-2011-2017 · Oct 6, 2016 · Terminated
    Minimal Access Straight Driver Product Usage: Pneumatic system
  • Z-2006-2017 · Oct 6, 2016 · Terminated
    Bearing Sleeve, 15CM Straight Product Usage: Pneumatic system
  • Z-0708-2014 · Oct 26, 2012 · Terminated
    Multiples Anspach Micro Curved Attachments (MCA) and Curved Burr Support S leves (Cutters and Attachments) MCA - MICRO CURVED ATTACHMENT, MCA5-05SD - 0.5MM DIAMOND BALL, 5.6CM, M
  • Z-0755-2014 · Mar 29, 2012 · Terminated
    MCA5-15SD - 1.5MM Diamond Ball, 5.6CM. All lots are included in recall. Intended for use in cutting and shaping delicate bone material, primarily in otologic procedures such as c
  • Z-0764-2014 · Mar 29, 2012 · Terminated
    MCA7-15SB - 1.5MM Fluted Ball, 7.3CM. All lots are included in recall. Intended for use in cutting and shaping delicate bone material, primarily in otologic procedures such as co
  • Z-0766-2014 · Mar 29, 2012 · Terminated
    MCA7-1SB - 1MM Fluted Ball, 7.3CM. All lots are included in recall. Intended for use in cutting and shaping delicate bone material, primarily in otologic procedures such as cochl
  • Z-0768-2014 · Mar 29, 2012 · Terminated
    MCA7-2SB - 2MM Fluted Ball, 7.3CM. All lots are included in recall. Intended for use in cutting and shaping delicate bone material, primarily in otologic procedures such as cochl
  • Z-0761-2014 · Mar 29, 2012 · Terminated
    MCA7-06SD - 0.6MM Diamond Ball, 7.3CM. All lots are included in recall. Intended for use in cutting and shaping delicate bone material, primarily in otologic procedures such as c
  • Z-0765-2014 · Mar 29, 2012 · Terminated
    MCA7-15SD - 1.5MM Diamond Ball, 7.3CM. All lots are included in recall. Intended for use in cutting and shaping delicate bone material, primarily in otologic procedures such as c
  • Z-0715-2014 · Mar 29, 2012 · Terminated
    Anspach MCA Cutting Burr, DFU Rx Only Designed for cutting and shaping delicate bone, primarily in otology procedures

…and 16 more.

Other DRILLS, BURRS, TREPHINES & ACCESSORIES (SIMPLE, POWERED) devices

All DRILLS, BURRS, TREPHINES & ACCESSORIES (SIMPLE, POWERED) devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page