Skip to content

OsteoMed 330-1614Recalls & reported problems

Osteomed LLC · 1.6mm x 14mm Fully Threaded Screw, Angled Locking · Class 2

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00845694023436), received between Mar 31, 2021 and Mar 31, 2021 — classified as 1 malfunction.

The most frequently reported specific device problem is “Insufficient Device Problem Information” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1
  • Insufficient Device Problem Information1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 31, 2021Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information; Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information

    ON FEBRUARY 25, 2021 OSTEOMED WAS NOTIFIED THAT, DURING AN IMPLANT OF A 1.6MM, 3 X 8 HOLES, "Y" PLATE (PART 333-1603/LOT 1145750) TWO (2) OF THE FOUR (4) SCREWS USED DID NOT LOCK IN THE PLATE. THESE 2 SCREWS WERE IDENTIFIED AS 1.6MM X 14MM FULL THREADED SCREW, LOCKING (PART 330-1614/LOT 1141838) AND 1.6MM X 16MM FULL THREADED SCREW, LOCKING (PART 330-1616 /LOT 1130797). THE IMPLANT AND EXPLANT OCCUR ON (B)(6) 2021, DURING THE SAME SURGERY. ON MARCH 02, 2021, OSTEOMED WAS NOTIFIED THAT, THE SURGERY WAS PROLONGED FOR ONE HOUR AND THE PATIENT HAD NO CONSEQUENCES OR IMPACT. PER THE REPORTER: "DURING THE PROCEDURE, THE SPECIALIST ASKS ME FOR A HPS 1.6 AV BLOCK Y PLATE WITH 11 HOLES (REF. 333-1603, BATCH 1145750) FROM SET 0056. THE SPECIALIST ASKED ME TO CUT IT AND I LEFT IT WITH 4 HOLES IN THE BRANCH. AFTER, PLACING THE PLATE ON THE BONE THE SPECIALIST FIXES IT WITH A STANDARD CRUCIFORM 1.6X10MM HPS SCREW (REF. 331-1610, BATCH. 1148546) AND A 1.6X8MM AV HPS LOCKED SCREW (REF. 330-1608, LOT. 1141744), ON THE BRANCH. THEN, HE ASK ME FOR A DRILL TO DRILL THE PROXIMAL HOLE OF THE Y-PLATE. THE SPECIALIST MEASURES AND ASKS ME FOR A 1.6X14MM AV. HPS LOCKED SCREW, (REF. 330-1614, BATCH 1141838)

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11600075 ↗

FDA clearance and classification

The FDA regulates product code HWC (screw, fixation, bone) under 21 CFR 888.3040 as a Class II device. 21 CFR 888.3040 ↗

Devices of this type normally need 510(k) clearance before sale.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the OsteoMed 330-1614

Has the OsteoMed 330-1614 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00845694023436), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the OsteoMed 330-1614?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Mar 31, 2021. Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the OsteoMed 330-1614?

None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Who makes the OsteoMed 330-1614, and is it still sold?

The FDA's device database lists Osteomed LLC as the company responsible for it (brand OsteoMed, model 330-1614). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Screw, fixation, bone devices

All Screw, fixation, bone devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page