OsteoMed 317-3034Recalls & reported problems
Osteomed LLC · 3.0mm X 34mm Cannulated Headless Screw · Class 2
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00845694027489), received between Mar 6, 2019 and Mar 6, 2019 — classified as 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Break1
Patient problems
- Device Embedded In Tissue or Plaque1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 6, 2019Break
ON (B)(6) 2019, OSTEOMED WAS NOTIFIED OF AN INCIDENT CONCERNING ONE OF OUR CANNULATED HEADLESS SCREWS. PER THE DISTRIBUTOR, THE PHYSICIAN PERFORMED AN MTP FUSION ON A PATIENT IN 2017. HE USED A 3.0 CANNULATED SCREW AND 4.0 CANNULATED SCREW TO GAIN JOIN COMPRESSION. ANOTHER PHYSICIAN FROM THE OFFICE CONTACTED THE DISTRIBUTOR TO REQUEST HIS DRIVERS TO REMOVE A BROKEN 3.0MM CANNULATED SCREW. THE DISTRIBUTOR WAS NOT ABLE TO ATTEND THE PROCEDURE AND FOLLOWED UP WITH THE PHYSICIAN TO FIND OUT IF HE WAS ABLE TO GET THE ENTIRE SCREW OUT. THE PHYSICIAN STATED THAT HE WAS ABLE TO GET ½ OF THE SCREW OUT, BUT THE PROXIMAL ½ OF THE SCREW WAS LEFT IN.
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 8396962 ↗
FDA clearance and classification
The FDA regulates product code HWC (screw, fixation, bone) under 21 CFR 888.3040 as a Class II device. 21 CFR 888.3040 ↗
Devices of this type normally need 510(k) clearance before sale.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the OsteoMed 317-3034
Has the OsteoMed 317-3034 been recalled?
No FDA recall record in our data names this exact device identifier (DI 00845694027489), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the OsteoMed 317-3034?
The FDA's MAUDE database lists 1 adverse event report for this device, received on Mar 6, 2019. That report lists device problem “Break” (1); patient problem “Device Embedded In Tissue or Plaque” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the OsteoMed 317-3034?
None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Who makes the OsteoMed 317-3034, and is it still sold?
The FDA's device database lists Osteomed LLC as the company responsible for it (brand OsteoMed, model 317-3034). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Screw, fixation, bone devices
- NA 03.043.029Synthes GmbH · Screw, fixation, bone498 reports
- OSTEORAPTOR 72201995Smith & Nephew, Inc. · Screw, fixation, bone248 reports
- Control 360 SK12Treace Medical Concepts, Inc. · Screw, Fixation, Bone195 reports
- HEALIX PEEK ORTHOCORD 222205Medos International Sàrl · Screw, fixation, bone186 reports
- PRECICE® Bone Transport System STP3.5-200Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-325Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-550Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-425Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page