OsteoMed 334-2426Recalls & reported problems
Osteomed LLC · 2.4mm x 26mm Fusion Screw · Class 2
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00845694032476), received between Feb 19, 2019 and Feb 19, 2019 — classified as 1 injury.
The most frequently reported specific device problem is “Migration” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Migration1
Patient problems
- Abdominal Pain1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryFeb 19, 2019Migration
ON (B)(4) 2019 OSTEOMED WAS NOTIFIED OF AN INCIDENT THAT OCCURRED WITH OUR 2.4MM X 26MM FUSION SCREW (P/N 334-2426). PER THE DISTRIBUTOR, THE CASE INVOLVED A NON-UNION. THE SURGERY WAS PERFORMED ON (B)(6) 2018. THE PATIENT RETURNED TO THE DOCTOR FOR A FOLLOW UP ON (B)(6) 2019. THE X-RAY TAKEN DURING THIS VISIT REVEALED MIGRATION OF THE FIXATION, AND THE PATIENT EXPRESSED SOME DISCOMFORT. THE PHYSICIAN PLACED THE PATIENT IN A CAST. THERE WAS ANOTHER FOLLOW-UP VISIT ON (B)(6) 2019. THE CAST REMAINED. THE REVISION SURGERY HAS BEEN SCHEDULED FOR FRIDAY, (B)(6) 2019. THE PHYSICIAN HAS RECOMMENDED THAT WE HAVE A BIGGER DIAMETER FIXATION SCREW.
Patient problems: Abdominal Pain
MAUDE report 8350154 ↗
Other Screw, fixation, bone devices
- NA 03.043.029Synthes GmbH · Screw, fixation, bone503 reports
- OSTEORAPTOR 72201995Smith & Nephew, Inc. · Screw, fixation, bone253 reports
- Control 360 SK12Treace Medical Concepts, Inc. · Screw, Fixation, Bone195 reports
- HEALIX PEEK ORTHOCORD 222205Medos International Sàrl · Screw, fixation, bone186 reports
- PRECICE® Bone Transport System STP3.5-375Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-225Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-200Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-300Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.