OsteoMed 359-2416Recalls & reported problems
Osteomed LLC · 2.4mm x 16mm Variable Angle Locking Screw · Class 2
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00845694092630), received between Jun 25, 2020 and Jun 25, 2020 — classified as 1 malfunction.
The most frequently reported specific device problem is “Patient Device Interaction Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Patient Device Interaction Problem1
Patient problems
- Bone Fracture(s)1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 25, 2020Patient Device Interaction Problem; Patient Device Interaction Problem
ON (B)(6) 2020, OSTEOMED WAS NOTIFIED THAT AN IMPLANTED 2.4MM X 16MM VARIABLE ANGLE LOCKING SCREW (P/N 359-2416) AND ASSOCIATED SCREWS AND PLATES WERE FOUND TO HAVE MIGRATED FROM THE IMPLANTED LOCATION. THE INITIAL IMPLANT WAS PERFORMED ON (B)(6) 2020 AND THE PRODUCTS WERE EXPLANTED ON (B)(6) 2020. AS PER SURGEON REPORT "I SAW THE PATIENT AFTER 2 WEEKS AND NO COMPLICATIONS WERE SPOTTED. DUE TO THE SITUATION I SUGGESTED NOT TO START THE REHABILITATION UNTIL THE 4TH POST-OPERATIVE WEEK. AFTER 4 WEEKS SHE CAME TO MY ATTENTION WITH PAIN AND A SEVERE ALTERATION OF THE NORMAL WRIST ANATOMY. NO TRAUMA WAS REPORTED BY THE PATIENT AND HER FAMILY MEMBERS. THE X-RAY SHOWED EARLY FAILURE OF THE IMPLANT, DISPLACEMENT OF THE FRACTURE AND MIGRATION OF TWO SCREWS. DURING THE PROCEDURE I'VE FOUND COMPLETE LOOSENING OF ALL THE SCREWS WITH THE ONLY EXCEPTION OF THE MOST PROXIMAL ONE, INCLUDING ALL THE LOCKING SCREWS. ONE SCREWS WAS FOUND 1.5 CM OUTSIDE OF THE PLATE AND STILL INSERTED ON THE PLATE HOLE, ONE WAS COMPLETELY EXPELLED (LOCKING SCREW AS WELL) AND WAS FOUND WITHIN THE FLEXOR TENDONS LYING CLOSE TO THE MEDIAN NERVE." THE FOLLOWING IMPLANTS (PLATE AND SCREWS) WERE INVOLVED WITH THIS INCIDENT:
Patient problems: Bone Fracture(s)
MAUDE report 10197843 ↗
Other Screw, fixation, bone devices
- NA 03.043.029Synthes GmbH · Screw, fixation, bone503 reports
- OSTEORAPTOR 72201995Smith & Nephew, Inc. · Screw, fixation, bone253 reports
- Control 360 SK12Treace Medical Concepts, Inc. · Screw, Fixation, Bone195 reports
- HEALIX PEEK ORTHOCORD 222205Medos International Sàrl · Screw, fixation, bone186 reports
- PRECICE® Bone Transport System STP3.5-375Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-225Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-200Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-300Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.