ANTEGRADE TARGETING MODULE FEMORAL NAIL SYSTEM 1271-300Recalls & reported problems

Advanced Orthopaedic Solutions, Inc. · Class 1

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00848665034073), received between Oct 5, 2023 and May 15, 2025 — classified as 3 malfunctions.

The most frequently reported specific device problem is “Crack” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 1 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Crack1
  • Defective Device1
  • Unintended Movement1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 15, 2025Defective Device; Defective Device

    ON 04/21/2025, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA (B)(4) THAT AN 1271-300 TARGETING MODULE DID NOT LINE UP AND WAS MISSING THE SCREW HOLE IN THE NAIL BY AT LEAST 6MM. WE WERE ABLE TO COMPLETE THE CASE WITH A FREEHAND LOCK. DELAYED US BY ABOUT 10 MINUTES AFTER WHICH THE CASE WAS COMPLETED WITHOUT ISSUE. NO ADVERSE PATIENT ISSUES.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22029708 ↗
  • MalfunctionDec 29, 2023Unintended Movement; Unintended Movement

    ON (B)(6) 2023, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA (B)(46.THAT A 1271-300 ANTEGRADE TARGETING MODULE HAD AN ISSUE WITH THE SCREW SHEATH BEING LOOSE ON THE JIG AND THEREFORE MISSING THE NAIL IMPLANT. THIS WAS DISCOVERED DURING AN UNSPECIFIED PROCEDURE, WITH NO REPORTED ADVERSE EVENT OR PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18419657 ↗
  • MalfunctionOct 5, 2023Crack; Crack

    ON (B)(6) 2023, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA SEMS-06023480 THAT AN 1271-200 TARGETING MODULE HAS A CRACK IN THE JIG AND THE BOLT THAT HOLDS THE JIG IS LOOSE. WHEN THE NAIL IS FULLY TIGHTENED ONTO THE JIG, THERE IS NO POSITIVE STOP, WHICH THEN CREATES THE NAIL TO BEGIN ROTATING WHILE THE NAIL IS ATTACHED. THIS WAS DISCOVERED DURING A CASE, WITH NO ADVERSE EFFECTS ON THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17876840 ↗

Other Orthopedic Manual Surgical Instrument devices