Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00849436000556), received between Nov 28, 2024 and Nov 28, 2024 — classified as 1 malfunction.
The most frequently reported specific device problem is “Increase in Pressure” (1 report).
3 other recalls cover devices cleared under the same FDA submission (K905235); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Increase in Pressure1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionNov 28, 2024Increase in Pressure; Increase in Pressure
PERCUSSIONAIRE WAS NOTIFIED ON NOVEMBER 1 REGARDING A POTENTIAL MALFUNCTION WITH A VDR VENTILATOR. IT WAS REPORTED BY THE CUSTOMER THAT THE VDR WAS MAKING UNUSUAL NOISES WHILE IN USE ON A PATIENT. THE VDR WAS CLOSELY MONITORED AFTER THIS INITIAL OBSERVATION. SHORTLY AFTER, IT WAS NOTICED ON THE VDR MONITOR THAT THE DISPLAYED PRESSURE ON THE OSCILLATORY CPAP WOULD STOP OSCILLATING AND UNEXPECTEDLY INITIATE A MANUAL BREATH AUTOMATICALLY. THE PRESSURE THEN ROSE INTO THE 70S BRIEFLY, AND THEN RETURNED TO THE OSCILLATORY CPAP MODE. THE CUSTOMER COMMUNICATED THAT THERE WAS AN AUDIBLE INCREASE IN FLOW, WHICH SUGGESTED THE PRESSURE WAS DELIVERED TO THE PATIENT. THE DEVICE WAS THEN REMOVED FROM THE PATIENT. THE PATIENT WAS CONFIRMED TO HAVE NO ADVERSE REACTIONS DUE TO THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20805839 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K905235. One submission often covers many models, so check the product and lot details in each record.
- Z-0960-2025 · Dec 23, 2024 · Open, ClassifiedVDR4 Phasitron Breathing Circuit Models that contain the venturi component: -A50094 D 5PK, Phasitron Kit, VDR, Single Patient, 5pk -A51001, VDR4 Control Unit Tester -PRT 991, VDR
- Z-0693-2024 · Mar 28, 2023 · Open, ClassifiedDistal Phasitron, Part: S20020, for use with Percussionaire VDR-4 control driver (or control unit)
- Z-0259-2024 · Sep 14, 2020 · CompletedMonitron II Waveform Analyzer, REF: S00015-1, used with ventilators.
Other Ventilator, Continuous, Facility Use devices
- Trilogy Trilogy100 Ventilator, United StatesRespironics, Inc. · VENTILATOR, CONTINUOUS, FACILITY USE92 deaths8,161 reports
- Trilogy Evo Trilogy Evo, USARespironics, Inc. · Ventilator, continuous, facility use6 recalls50 deaths4,393 reports
- Trilogy 100 Trilogy 100 W/ Bluetooth, USARespironics, Inc. · VENTILATOR, CONTINUOUS, FACILITY USE65 deaths4,569 reports
- CARESCAPE R860Datex-Ohmeda Inc · VENTILATOR, CONTINUOUS, FACILITY USE1 recall1 death4,346 reports
- HAMILTON-C1 161001Hamilton Medical AG · Ventilator, Continuous, Facility Use2 recalls12 deaths1,849 reports
- Trilogy Trilogy O2 Ventilator JapanRespironics, Inc. · VENTILATOR, CONTINUOUS, FACILITY USE7 deaths1,900 reports
- Trilogy Trilogy 202 Ventilator InternationalRespironics, Inc. · VENTILATOR, CONTINUOUS, FACILITY USE11 deaths1,564 reports
- HAMILTON-C6 160021Hamilton Medical AG · Ventilator, Continuous, Facility Use5 recalls10 deaths1,175 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page