Pathfinder® Endoscope Overtube GI 110140-2Recalls & reported problems
Neptune Medical Inc. · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00850006222087), received between Dec 30, 2024 and Dec 30, 2024 — classified as 1 malfunction.
The most frequently reported specific device problem is “Off-Label Use” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Off-Label Use1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 30, 2024Off-Label Use; Off-Label Use
A PATIENT WAS ADMITTED FOR COLONOSCOPY TO REMOVE A FOREIGN BODY THAT HAD MIGRATED TO THE DISTAL COLON. THE MD DETERMINED THAT THE DEVICE WOULD BE A USEFUL TOOL TO HELP WITH THE REMOVAL OF THE FOREIGN BODY, AND REQUESTED THE OVERTUBE FOR THE PROCEDURE. UPON EXAMINATION OF THE DEVICE BY THE PHYSICIAN PERFORMING THE PROCEDURE, THE PHYSICIAN ASKED THAT THE DISTAL TIP (TAPERED PORTION) OF THE DEVICE BE TRIMMED TO CREATE A LARGER WORKING CHANNEL. AT THE REQUEST OF THE MD, A COMPANY EMPLOYEE TRIMMED THE DISTAL TIP USING SCISSORS. THE DEVICE WAS INSERTED INTO THE PATIENT AND THE PROCEDURE WAS COMPLETED WITHOUT INCIDENT. THE DEVICE IS A HOLLOW TUBE FOR USE OVER A FLEXIBLE GASTROINTESTINAL ENDOSCOPE. THE ENDOSCOPE IS INSERTED THROUGH THE PROXIMAL END OF THE DEVICE AND COMES OUT THE DISTAL END. THE DISTAL TIP IS A TAPERED, ATRAUMATIC SILICONE TIP THAT IS ATTACHED TO THE DISTAL END OF PATHFINDER. PER INTERNAL DOCUMENTATION, THE POTENTIAL HARM IN THE EVENT THE ATRAUMATIC TIP IS LOST AND THE DEVICE IS INSERTED INTO THE PATIENT IS GI TRACT DAMAGE UP TO AND INCLUDING PERFORATION OF PATIENT ANATOMY REQUIRING SURGICAL INTERVENTION. THERE WAS NO REPORTED ADVERSE EVENT OR HARM OCCURRING IN THIS CASE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21036387 ↗
Other Endoscopic Access Overtube, Gastroenterology-Urology devices
- EVIS EXERA II SMALL INTESTINAL VIDEOSCOPE OLYMPUS SIF TYPE Q180Olympus Medical Systems Corp. · endoscopic access overtube, gastroenterology-urology1 recall42 reports
- Trokamed WA2PS20STROKAMED GmbH · Endoscopic Access Overtube, Gastroenterology-Urology1 recall2 deaths2 reports
- Trokamed WA2PS20LTROKAMED GmbH · Endoscopic Access Overtube, Gastroenterology-Urology1 recall2 deaths2 reports
- Trokamed WA2PS18LTROKAMED GmbH · Endoscopic Access Overtube, Gastroenterology-Urology1 recall0 reports
- Trokamed WA2PS18STROKAMED GmbH · Endoscopic Access Overtube, Gastroenterology-Urology1 recall0 reports
- Navigator HD M0062502220Boston Scientific Corporation · endoscopic access overtube, gastroenterology-urology1 death31 reports
- Navigator HD M0062502230Boston Scientific Corporation · endoscopic access overtube, gastroenterology-urology29 reports
- Proxis™ Ureteral Access Sheath 231045C. R. Bard, Inc. · endoscopic access overtube, gastroenterology-urology22 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026