Pathfinder® Endoscope Overtube GI 110140-2Recalls & reported problems

Neptune Medical Inc. · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00850006222087), received between Dec 30, 2024 and Dec 30, 2024 — classified as 1 malfunction.

The most frequently reported specific device problem is “Off-Label Use” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 1 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Off-Label Use1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionDec 30, 2024Off-Label Use; Off-Label Use

    A PATIENT WAS ADMITTED FOR COLONOSCOPY TO REMOVE A FOREIGN BODY THAT HAD MIGRATED TO THE DISTAL COLON. THE MD DETERMINED THAT THE DEVICE WOULD BE A USEFUL TOOL TO HELP WITH THE REMOVAL OF THE FOREIGN BODY, AND REQUESTED THE OVERTUBE FOR THE PROCEDURE. UPON EXAMINATION OF THE DEVICE BY THE PHYSICIAN PERFORMING THE PROCEDURE, THE PHYSICIAN ASKED THAT THE DISTAL TIP (TAPERED PORTION) OF THE DEVICE BE TRIMMED TO CREATE A LARGER WORKING CHANNEL. AT THE REQUEST OF THE MD, A COMPANY EMPLOYEE TRIMMED THE DISTAL TIP USING SCISSORS. THE DEVICE WAS INSERTED INTO THE PATIENT AND THE PROCEDURE WAS COMPLETED WITHOUT INCIDENT. THE DEVICE IS A HOLLOW TUBE FOR USE OVER A FLEXIBLE GASTROINTESTINAL ENDOSCOPE. THE ENDOSCOPE IS INSERTED THROUGH THE PROXIMAL END OF THE DEVICE AND COMES OUT THE DISTAL END. THE DISTAL TIP IS A TAPERED, ATRAUMATIC SILICONE TIP THAT IS ATTACHED TO THE DISTAL END OF PATHFINDER. PER INTERNAL DOCUMENTATION, THE POTENTIAL HARM IN THE EVENT THE ATRAUMATIC TIP IS LOST AND THE DEVICE IS INSERTED INTO THE PATIENT IS GI TRACT DAMAGE UP TO AND INCLUDING PERFORATION OF PATIENT ANATOMY REQUIRING SURGICAL INTERVENTION. THERE WAS NO REPORTED ADVERSE EVENT OR HARM OCCURRING IN THIS CASE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21036387 ↗

Other Endoscopic Access Overtube, Gastroenterology-Urology devices

All Endoscopic Access Overtube, Gastroenterology-Urology devices →