Enclose II® EN240vRecalls & reported problems

Vitalitec International, Inc. · Anastomosis assist device · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00852621004192), received between May 6, 2026 and May 6, 2026 — classified as 1 malfunction.

The most frequently reported specific device problem is “Difficult to Remove” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 1 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Difficult to Remove1
  • Mechanical Problem1

Patient problems

  • Hemorrhage/Blood Loss/Bleeding1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 6, 2026Mechanical Problem; Difficult to Remove

    IT WAS REPORTED THAT AFTER ENCLOSE2 WAS INSERTED INTO THE AORTA AND A PUNCH-OUT WAS PERFORMED, BRISK BLEEDING OCCURRED, PROMPTING DISCONTINUATION OF ITS USE. WHEN ATTEMPTS WERE MADE TO WITHDRAW THE DEVICE BY TURNING THE UPPER JAW AND LOWER JAW DIALS, IT COULD NOT BE REMOVED. AFTER SEVERAL ADDITIONAL ATTEMPTS, IT WAS FINALLY ABLE TO BE WITHDRAWN. AFTER INSERTION OF THE SUBJECT DEVICE AND COMPLETION OF THE PUNCH-OUT, BLEEDING BECAME UNCONTROLLABLE. A DECISION WAS MADE TO TEMPORARILY WITHDRAW THE DEVICE; HOWEVER, THE LOWER JAW DIAL DID NOT ROTATE SMOOTHLY, AND IT TOOK TIME TO FULLY CLOSE THE LOWER JAW, RESULTING IN DIFFICULTY WITHDRAWING THE DEVICE. THE DEVICE WAS ULTIMATELY WITHDRAWN WITHOUT INCIDENT, AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY USING ANOTHER ENCLOSE II DEVICE. HEMOSTASIS WAS CHECKED USING THE EXTENSION TUBE, AND NO PROBLEMS WERE OBSERVED. ALTHOUGH THERE WAS DIFFICULTY IN REMOVING THE PRODUCT, THERE WAS NO DAMAGE TO THE AORTA. THE PHYSICIAN STATED THAT THERE WERE NO PROBLEMS DURING THE SCALPEL INCISION OR WHEN USING THE PUNCHER. NO PARTICULAR INFORMATION HAS BEEN OBTAINED REGARDING THE PATIENT'S OUTCOME. THE PHYSICIAN HAS USED THIS PRODUCT IN APPROXIMATELY 10 CASES.

    Patient problems: Hemorrhage/Blood Loss/Bleeding

    MAUDE report 25095035 ↗