BEST PAK Access Needle PK1001Recalls & reported problems
Lacey Manufacturing Company, LLC · Pedicle Access Needle PAK Bevel/Bevel · Class 1
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00853508002218), received between Jun 16, 2020 and Jun 16, 2020 — classified as 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Break1
- Material Fragmentation1
- Material Twisted/Bent1
Patient problems
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 16, 2020Break; Material Fragmentation; Material Twisted/Bent; Break; Material Fragmentation; Material Twisted/Bent
IT WAS REPORTED THAT ON (B)(6) 2020, INTRA-OP, THE BONE WAS HARD AND IT WAS MANAGED TO INSERT THE PRODUCT INTO THE PEDICLE, BUT THE INNER CYLINDER COULD NOT BE REMOVED AND IT WAS UNABLE TO PROCEED TO THE NEXT STEP. THEREFORE THE PROCEDURE WAS CHANGED TO OPEN. WHEN CHECKING THE IMAGE TO CHECK THE LEVEL IT WAS FOUND THAT FRAGMENTS OF THE OUTER CYLINDER HAVE REMAINED INSIDE THE PEDICLE AND INSIDE THE VERTEBRAL BODY. AN ATTEMPT WAS MADE TO REMOVE THE FRAGMENTS USING AIRTOME AND A PLIER BUT FAILED AND WOUND CLOSURE WAS PERFORMED WITH THE FRAGMENTS REMAINED BASED ON THE SURGEON'S JUDGEMENT THAT THE FRAGMENTS WOULD NOT COME OUT. THERE WAS A DELAY OF MORE THAN 60 MINUTES AS A RESULT OF THIS EVENT. THERE WAS NO PATIENT COMPLICATIONS AS A RESULT OF THIS EVENT. AN UPDATE WAS RECEIVED ON 31 MAR 2020: PROCEDURE INVOLVED: FIXATION AT TH10-L3 USING VOYAGER 55/60. THE BONE WAS HARD AND WHEN THE PAK WAS HAMMERED INTO THE LEFT SIDE OF THE L2 VERTEBRAL BODY, BUT THE INNER CYLINDER COULD NOT BE REMOVED. BY CHECKING THE IMAGE, THE NEEDLE APPEARED TO BE BENT, SO THE PAK NEEDLE ITSELF WAS PULLED OUT. IT WAS SAIS AT THIS POINT, IT WAS NOTICED THAT THE OUTER CYLINDER WAS BROKEN, BUT WHEN THE IMAGE WAS CHEC
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 10157243 ↗
Other Orthopedic Manual Surgical Instrument devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page