Skip to content

iTClamp® 9100Recalls & reported problems

Innovative Trauma Care Inc · The iTClamp® quickly controls critical bleeding by closing the skin to create a temporary, contained hematoma until surgical repair. The iTClamp® is a self-locking trauma clamp with needles that penetrate the skin to evert the skin edges between pressure bars of the device and anchor it to the skin to reduce slippage and leakage. Pressure is evenly distributed across the bars, which seal the skin over a wound. An adjustable locking mechanism increases or decreases pressure across the wound to achieve a fluid tight seal. · Class 2

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00854874004004), received between Jul 17, 2017 and Jul 17, 2017 — classified as 1 injury.

The most frequently reported specific device problem is “Human Factors Issue” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Human Factors Issue1

Patient problems

  • Blood Loss1
  • Hematoma1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryJul 17, 2017Human Factors Issue; Human Factors Issue

    IT WAS REPORTED THAT AN ITCLAMP WAS USED TO CONTROL EXTERNAL BLEEDING FROM A LACERATION IN THE JUNCTIONAL AREA OF A (B)(6) YEAR OLD MALE PATIENT. THE LACERATION CAUSED A COMPLETE TRANSECTION OF HIS FEMORAL ARTERY AND VEIN IN THE JUNCTIONAL AREA. UPON ARRIVAL AT THE EMERGENCY DEPARTMENT, IT WAS OBSERVED THAT THE BLEEDING WAS CONTINUING INTO THE INTERNAL SPACE RESULTING IN AN EXPANDING HEMATOMA. BLEEDING CONTROL WAS OBTAINED WITH DIRECT PRESSURE TO THE INGUINAL AREA. THE VOLUME OF BLOOD LOSS WAS POTENTIALLY LIFE-THREATENING. THE FEMORAL ARTERY AND VEIN WERE REPAIRED DURING SURGERY. NO FURTHER ISSUES WERE REPORTED.

    Patient problems: Blood Loss; Hematoma

    MAUDE report 6720492 ↗

FDA clearance and classification

Cleared through Special 510(k) K150813 on Apr 30, 2015 (decision: Substantially Equivalent). Submitted by Innovative Trauma Care, Inc. as “iTClamp50”. The FDA review took 34 days. FDA record ↗

The FDA regulates product code DXC (clamp, vascular) under 21 CFR 870.4450 as a Class II device. 21 CFR 870.4450 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the iTClamp® 9100

Has the iTClamp® 9100 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00854874004004), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the iTClamp® 9100?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Jul 17, 2017. That report lists device problem “Human Factors Issue” (1); patient problems “Blood Loss” (1) and “Hematoma” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the iTClamp® 9100?

None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the iTClamp® 9100 FDA approved?

It was cleared through Special 510(k) K150813 on Apr 30, 2015. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Is the iTClamp® 9100 MRI safe?

According to the device's FDA GUDID record, its labeling lists it as MR Unsafe: it should not be taken into an MRI scanner room.

Who makes the iTClamp® 9100, and is it still sold?

The FDA's device database lists Innovative Trauma Care Inc as the company responsible for it (brand iTClamp®, model 9100). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Clamp, Vascular devices

All Clamp, Vascular devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page