Gauthier Biomedical G900100Recalls & reported problems
Gauthier Biomedical, Inc. · Multi-Color Ratcheting T-Handle · Class 1
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00858325005015), received between Aug 12, 2021 and Aug 12, 2021 — classified as 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Break1
Patient problems
- Device Embedded In Tissue or Plaque1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 12, 2021Break; Break
MEDTRONIC RECEIVED INFORMATION REGARDING SPINAL INSTRUMENTS DURING A L1-S1 REVISION AND FUSION. IT WAS REPORTED THAT THE DOCTOR WAS USING A MALLET TO ADVANCE THE THORACIC PROBE THROUGH THE PEDICLE AND INTO THE VERTEBRAL BODY FOR SCREW PREPARATION. AFTER MALLETING THE PROBE, THE DOCTOR REMOVED IT AND NOTICED THE TIP OF THE PROBE BROKE OFF AT THE 10MM MARK. THE DOCTOR USED THE PASSIVE PLANAR PROBE AND PLACED IT DOWN THE HOLE THE TIP WAS LOCATED IN. THE DOCTOR CONCLUDED THE TIP OF THE BROKEN PROBE WAS TOO FAR INTO THE VERTEBRAL BODY TO RETRIEVE IT WITHOUT CAUSING HARM TO THE PATIENT. IT WAS NOTED THAT AROUND 10MM OF THE TIP OF THE THORACIC PROBE WAS LEFT IN THE PATIENT AS THE PHYSICIAN CONCLUDED THEY WOULD CAUSE MORE HARM TRYING TO RETRIEVE IT THEN IF THEY LEFT IT. THE RELATIONSHIP BETWEEN THE REPORTED EVENT AND THE USE OF MEDTRONIC PRODUCTS WAS UNKNOWN. THE PATIENT STATUS WAS ALIVE WITH NO INJURY.
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 12316414 ↗
Other Orthopedic Manual Surgical Instrument devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page