The FDA's MAUDE database contains 10 adverse event reports that list this exact device (DI 00868906000100), received between Nov 25, 2019 and Mar 20, 2020 — classified as 10 malfunctions.
The most frequently reported specific device problem is “High Readings” (10 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- High Readings10
Patient problems
- Not Applicable10
Recent adverse event reports
The 10 most recent of 10 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 20, 2020High Readings; High Readings
A CUSTOMER COMPLAINT PROMPTED AN INVESTIGATION BY OUR COMPANY INTO A POTENTIAL PRODUCT MALFUNCTION. WE HAD THE CUSTOMER'S PRODUCT TESTED BY A 3RD-PARTY (INITIAL REPORTER) WITH WHOLE BLOOD AT A LOW GLUCOSE LEVEL AND A HIGH GLUCOSE LEVEL. THE STRIP READINGS WERE COMPARED TO THE GLUCOSE LEVELS, WHICH WERE MEASURED USING A YSI 2300 STAT PLUS GLUCOSE ANALYZER. BY THIS METHOD, IT WAS DETERMINED THAT THE CUSTOMER'S PRODUCT WAS GIVING FALSELY HIGH RESULTS AT THE LOW GLUCOSE LEVEL, WHILE THE HIGH GLUCOSE LEVEL RESULTS WERE WITHIN ACCEPTABLE LIMITS.
Patient problems: Not Applicable
MAUDE report 9862935 ↗MalfunctionDec 18, 2019High Readings; High Readings
A CUSTOMER COMPLAINT PROMPTED AN INVESTIGATION BY OUR COMPANY INTO POTENTIAL PRODUCT MALFUNCTION. WE HAD THE CUSTOMER'S PRODUCT TESTED BY A 3RD-PARTY (INITIAL REPORTER) AT A LOW GLUCOSE LEVEL AND A HIGH GLUCOSE LEVEL. THE STRIP READINGS WERE COMPARED TO THE GLUCOSE LEVELS, WHICH WERE MEASURED USING A YSI 2300 STAT PLUS GLUCOSE ANALYZER. BY THIS METHOD, IT WAS DETERMINED THAT THE CUSTOMER'S PRODUCT WAS GIVING FALSELY HIGH RESULTS AT BOTH THE LOW AND HIGH GLUCOSE LEVELS.
Patient problems: Not Applicable
MAUDE report 9491956 ↗MalfunctionNov 25, 2019High Readings; High Readings
A CUSTOMER COMPLAINT PROMPTED AN INVESTIGATION BY OUR COMPANY INTO A POTENTIAL PRODUCT MALFUNCTION. WE HAD THE CUSTOMER'S PRODUCT TESTED BY A 3RD-PARTY (INITIAL REPORTER) WITH WHOLE BLOOD AT A LOW GLUCOSE LEVEL AND A HIGH GLUCOSE LEVEL. THE STRIP READINGS WERE COMPARED TO THE GLUCOSE LEVELS, WHICH WERE MEASURED USING A YSI 2300 STAT PLUS GLUCOSE ANALYZER. BY THIS METHOD, IT WAS DETERMINED THAT THE CUSTOMER'S PRODUCT WAS GIVING FALSELY HIGH RESULTS AT THE LOW GLUCOSE LEVEL, WHILE THE HIGH GLUCOSE LEVEL RESULTS WERE WITHIN ACCEPTABLE LIMITS.
Patient problems: Not Applicable
MAUDE report 9372448 ↗MalfunctionNov 25, 2019High Readings; High Readings
A CUSTOMER COMPLAINT PROMPTED AN INVESTIGATION BY OUR COMPANY INTO POTENTIAL PRODUCT MALFUNCTION. WE RAN 10 CONTROL TESTS ON THE CUSTOMER'S PRODUCT USING ONE TOUCH ULTRA CONTROL SOLUTION AND A ONE TOUCH ULTRA 2 METER. WE THEN CALCULATED THE MEAN OF THOSE RESULTS AND FOUND THEM TO BE OUT OF RANGE. WE THEN HAD RETAINS FROM THE SAME LOT OF PRODUCT TESTED BY A 3RD-PARTY (INITIAL REPORTER) AT A LOW GLUCOSE LEVEL AND A HIGH GLUCOSE LEVEL. THE STRIP READINGS WERE COMPARED TO THE GLUCOSE LEVELS, WHICH WERE MEASURED USING A YSI 2300 STAT PLUS GLUCOSE ANALYZER. BY THIS METHOD, IT WAS DETERMINED THAT THE RETAIN SAMPLE PRODUCT WAS GIVING FALSELY HIGH RESULTS AT BOTH THE LOW AND HIGH GLUCOSE LEVELS.
Patient problems: Not Applicable
MAUDE report 9372443 ↗MalfunctionNov 25, 2019High Readings; High Readings
A CUSTOMER COMPLAINT PROMPTED AN INVESTIGATION BY OUR COMPANY INTO POTENTIAL PRODUCT MALFUNCTION. WE HAD THE CUSTOMER'S PRODUCT TESTED BY A 3RD-PARTY (INITIAL REPORTER) AT A LOW GLUCOSE LEVEL AND A HIGH GLUCOSE LEVEL. THE STRIP READINGS WERE COMPARED TO THE GLUCOSE LEVELS, WHICH WERE MEASURED USING A YSI 2300 STAT PLUS GLUCOSE ANALYZER. BY THIS METHOD, IT WAS DETERMINED THAT THE CUSTOMER'S PRODUCT WAS GIVING FALSELY HIGH RESULTS AT BOTH THE LOW AND HIGH GLUCOSE LEVELS.
Patient problems: Not Applicable
MAUDE report 9372439 ↗MalfunctionNov 25, 2019High Readings; High Readings
A CUSTOMER COMPLAINT PROMPTED AN INVESTIGATION BY OUR COMPANY INTO A POTENTIAL PRODUCT MALFUNCTION. WE HAD THE CUSTOMER'S PRODUCT TESTED BY A 3RD-PARTY (INITIAL REPORTER) WITH WHOLE BLOOD AT A LOW GLUCOSE LEVEL AND A HIGH GLUCOSE LEVEL. THE STRIP READINGS WERE COMPARED TO THE GLUCOSE LEVELS, WHICH WERE MEASURED USING A YSI 2300 STAT PLUS GLUCOSE ANALYZER. BY THIS METHOD, IT WAS DETERMINED THAT THE CUSTOMER'S PRODUCT WAS GIVING FALSELY HIGH RESULTS AT BOTH THE LOW AND HIGH GLUCOSE LEVELS.
Patient problems: Not Applicable
MAUDE report 9372438 ↗MalfunctionNov 25, 2019High Readings; High Readings
A CUSTOMER COMPLAINT PROMPTED AN INVESTIGATION BY OUR COMPANY INTO POTENTIAL PRODUCT MALFUNCTION. WE HAD THE CUSTOMER'S PRODUCT TESTED BY A 3RD-PARTY (INITIAL REPORTER) AT A LOW GLUCOSE LEVEL AND A HIGH GLUCOSE LEVEL. THE STRIP READINGS WERE COMPARED TO THE GLUCOSE LEVELS, WHICH WERE MEASURED USING A YSI 2300 STAT PLUS GLUCOSE ANALYZER. BY THIS METHOD, IT WAS DETERMINED THAT THE CUSTOMER'S PRODUCT WAS GIVING FALSELY HIGH RESULTS AT BOTH THE LOW AND HIGH GLUCOSE LEVELS.
Patient problems: Not Applicable
MAUDE report 9372437 ↗MalfunctionNov 25, 2019High Readings; High Readings
A CUSTOMER COMPLAINT PROMPTED AN INVESTIGATION BY OUR COMPANY INTO POTENTIAL PRODUCT MALFUNCTION. WE HAD THE CUSTOMER'S PRODUCT TESTED BY A 3RD-PARTY (INITIAL REPORTER) AT A LOW GLUCOSE LEVEL AND A HIGH GLUCOSE LEVEL. THE STRIP READINGS WERE COMPARED TO THE GLUCOSE LEVELS, WHICH WERE MEASURED USING A YSI 2300 STAT PLUS GLUCOSE ANALYZER. BY THIS METHOD, IT WAS DETERMINED THAT THE CUSTOMER'S PRODUCT WAS GIVING FALSELY HIGH RESULTS AT BOTH THE LOW AND HIGH GLUCOSE LEVELS.
Patient problems: Not Applicable
MAUDE report 9372431 ↗MalfunctionNov 25, 2019High Readings; High Readings
A CUSTOMER COMPLAINT PROMPTED AN INVESTIGATION BY OUR COMPANY INTO A POTENTIAL PRODUCT MALFUNCTION. WE HAD THE CUSTOMER'S PRODUCT TESTED BY A 3RD-PARTY (INITIAL REPORTER) WITH WHOLE BLOOD AT A LOW GLUCOSE LEVEL AND A HIGH GLUCOSE LEVEL. THE STRIP READINGS WERE COMPARED TO THE GLUCOSE LEVELS, WHICH WERE MEASURED USING A YSI 2300 STAT PLUS GLUCOSE ANALYZER. BY THIS METHOD, IT WAS DETERMINED THAT THE CUSTOMER'S PRODUCT WAS GIVING FALSELY HIGH RESULTS AT THE LOW GLUCOSE LEVEL, WHILE THE HIGH GLUCOSE LEVEL RESULTS WERE WITHIN ACCEPTABLE LIMITS.
Patient problems: Not Applicable
MAUDE report 9372430 ↗MalfunctionNov 25, 2019High Readings; High Readings
A CUSTOMER COMPLAINT PROMPTED AN INVESTIGATION BY OUR COMPANY INTO POTENTIAL PRODUCT MALFUNCTION. WE HAD THE CUSTOMER'S PRODUCT TESTED BY A 3RD-PARTY (INITIAL REPORTER) AT A LOW GLUCOSE LEVEL AND A HIGH GLUCOSE LEVEL. THE STRIP READINGS WERE COMPARED TO THE GLUCOSE LEVELS, WHICH WERE MEASURED USING A YSI 2300 STAT PLUS GLUCOSE ANALYZER. BY THIS METHOD, IT WAS DETERMINED THAT THE CUSTOMER'S PRODUCT WAS GIVING FALSELY HIGH RESULTS AT BOTH THE LOW AND HIGH GLUCOSE LEVELS.
Patient problems: Not Applicable
MAUDE report 9372429 ↗
Other Glucose Oxidase, Glucose devices
- TRUEtrack TRUEtrack 50 Blood Glucose Test StripsTrividia Health, Inc. · Glucose Oxidase, Glucose153 reports
- HemoCue® Glucose 201 Microcuvettes 110706Hemocue AB · Glucose Oxidase, Glucose2 recalls0 reports
- VITROS 1707801Ortho-Clinical Diagnostics, Inc. · GLUCOSE OXIDASE, GLUCOSE1 recall48 reports
- Prodigy AutoCode Blood Glucose Monitoring System 051885Prodigy Diabetes Care, LLC · Glucose Oxidase, Glucose93 reports
- OneTouch Ultra Blue 022-895LifeScan U.S. LLC · GLUCOSE OXIDASE, GLUCOSE1 recall7 reports
- OneTouch Ultra Blue 020-994LifeScan U.S. LLC · GLUCOSE OXIDASE, GLUCOSE1 recall2 reports
- Alere Cholestech LDX® 10-991Alere San Diego, Inc. · Glucose Oxidase, Glucose1 recall1 report
- Alere Cholestech LDX® 14-531Alere San Diego, Inc. · Glucose Oxidase, Glucose1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page