ORTHOPEDIC SALVAGE SYSTEM (OSS) CP111827Recalls & reported problems
Biomet Orthopedics, LLC · Class 2 · Implant
All models of ORTHOPEDIC SALVAGE SYSTEM (OSS) (8)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 0
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 1
Summary
No MAUDE adverse event reports in our data reference this device identifier directly.
1 FDA recall record name this device's identifier.
8 other recalls cover devices cleared under the same FDA submission (K020381, K043547); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Recalls naming this device
- Aug 21, 2019Class IITerminated
Elevated levels of bacterial endotoxin and residual debris remain on the devices due to cleaning issue.
Z-0526-2020 · Root cause: Environmental control · Recall details · FDA record ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K020381, K043547. One submission often covers many models, so check the product and lot details in each record.
- Z-0305-2018 · Jun 5, 2017 · TerminatedRED SEXP DSTL FEM 19CM LT ASSY, model # CP111828
- Z-0304-2018 · Jun 5, 2017 · TerminatedRED SEXP DSTL FEM 19CM RT ASSY, model # CP111817
- Z-1528-2009 · May 19, 2009 · TerminatedBiomet OSS Letson Proximal Femoral Trial 7 cm resection/right, stainless steel, Biomet Orthopedics, Inc., Warsaw, IN; REF 32-472088. A non-powered, orthopedic manual surgical inst
- Z-1529-2009 · May 19, 2009 · TerminatedBiomet OSS Letson Proximal Femoral Trial 7 cm resection/left, stainless steel, Biomet Orthopedics, Inc., Warsaw, IN; REF 32-472089. A non-powered, orthopedic manual surgical instr
- Z-1527-2009 · May 19, 2009 · TerminatedBiomet OSS FINN Proximal Femoral Trial 7 cm resection/left, stainless steel, Biomet Orthopedics, Inc., Warsaw, IN; REF 32-472087. A non-powered, orthopedic manual surgical instrum
- Z-1530-2009 · May 19, 2009 · TerminatedBiomet OSS Elliptical Proximal Femoral Trial 7 cm, right provisional, stainless steel, Biomet Orthopedics, Inc., Warsaw, IN; REF 32-472124. A non-powered, orthopedic manual surgic
- Z-1526-2009 · May 19, 2009 · TerminatedBiomet OSS FINN Proximal Femoral Trial 7 cm resection/right, stainless steel, Biomet Orthopedics, Inc., Warsaw, IN; REF 32-472086. A non-powered, orthopedic manual surgical instru
- Z-1531-2009 · May 19, 2009 · TerminatedBiomet OSS Elliptical Proximal Femoral Trial 7 cm left provisional, stainless steel, Biomet Orthopedics, Inc., Warsaw, IN; REF 32-472125. A non-powered, orthopedic manual surgical
Other Prosthesis, hip, hemi-, femoral, metal/polymer, cemented or uncemented devices
- STAGEONE 431209Biomet Orthopedics, LLC · Prosthesis, hip, hemi-, femoral, metal/polymer, cemented or uncemented2 recalls0 reports
- SELF CENTERING 1035-45-000Depuy Orthopaedics, Inc. · Prosthesis, hip, hemi-, femoral, metal/polymer, cemented or uncemented84 reports
- LFIT 6260-9-036Howmedica Osteonics Corp. · Prosthesis, hip, hemi-, femoral, metal/polymer, cemented or uncemented80 reports
- ACTIS 101011060Depuy (Ireland) · Prosthesis, hip, hemi-, femoral, metal/polymer, cemented or uncemented66 reports
- RINGLOC BI-POLAR HIP SYSTEM 11-165228Biomet Orthopedics, LLC · Prosthesis, hip, hemi-, femoral, metal/polymer, cemented or uncemented1 recall1 death12 reports
- SELF CENTERING 1035-44-000Depuy Orthopaedics, Inc. · Prosthesis, hip, hemi-, femoral, metal/polymer, cemented or uncemented60 reports
- TANDEM 71324046Smith & Nephew, Inc. · Prosthesis, hip, hemi-, femoral, metal/polymer, cemented or uncemented1 recall9 reports
- TAPERLOC COMPLETE XR 123 MICRO FEMORAL 51-145170Biomet Orthopedics, LLC · Prosthesis, hip, hemi-, femoral, metal/polymer, cemented or uncemented59 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026 · each recall links to the FDA recall notice
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page