Skip to content

STAGEONE 431209Recalls & reported problems

Biomet Orthopedics, LLC · Class 2

All models of STAGEONE (17)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
0
Deaths reported
0
Injuries reported
0
Recalls naming it
2

Summary

No MAUDE adverse event reports in our data reference this device identifier directly.

2 FDA recall records name this device's identifier.

3 other recalls cover devices cleared under the same FDA submission (K052990); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Recalls naming this device

  1. Feb 26, 2020Class IITerminated

    Potentially insufficient cleaning process or potential inadequate process monitoring for cleaning parameters.

    Z-1654-2020 · Root cause: Process control · Recall details · FDA record ↗

  2. Sep 21, 2018Class IITerminated

    There is a potential for comingling of the 43MM and 51 MM molds

    Z-0399-2019 · Root cause: Error in labeling · Recall details · FDA record ↗

FDA clearance and classification

Cleared through 510(k) K052990 on Dec 16, 2005 (decision: Substantially Equivalent). Submitted by Biomet, Inc. as “Stageone Disposable Cement Spacer Mold For Temporary Hip Prosthesis With Reinforcement Stem”. The FDA review took 53 days. FDA record ↗

The FDA regulates product code KWY (prosthesis, hip, hemi-, femoral, metal/polymer, cemented or uncemented) under 21 CFR 888.3390 as a Class II device. 21 CFR 888.3390 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Recalls under the same FDA submission

These recalls involve devices cleared under K052990. One submission often covers many models, so check the product and lot details in each record.

  • Z-1655-2020 · Feb 26, 2020 · Terminated
    BIOMET StageOne, Hip Cement Spacer Mold w/Reinforcement, 13 X 145 MM, 57 MM, Silicone, Sterile, Item 431213.
  • Z-1656-2020 · Feb 26, 2020 · Terminated
    BIOMET StageOne, Hip Cement Spacer Mold w/Reinforcement, 17 X 165 MM, 64 MM, Silicone, Sterile, Item 431217.
  • Z-1653-2020 · Feb 26, 2020 · Terminated
    BIOMET StageOne, Hip Cement Spacer Mold w/Reinforcement, 9 X 125 MM, 43 MM, Silicone, Sterile, Item 431207.

Common questions about the STAGEONE 431209

Has the STAGEONE 431209 been recalled?

Yes. 2 FDA recall records name this device's identifier: 2 closed (terminated) by the FDA. The most recent, Z-1654-2020 (Class II), began on Feb 26, 2020: Potentially insufficient cleaning process or potential inadequate process monitoring for cleaning parameters. If you use this device, follow the manufacturer's notice and your healthcare provider's advice.

Is the STAGEONE 431209 FDA approved?

It was cleared through 510(k) K052990 on Dec 16, 2005. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Who makes the STAGEONE 431209, and is it still sold?

The FDA's device database lists Biomet Orthopedics, LLC as the company responsible for it (brand STAGEONE, model 431209). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Prosthesis, hip, hemi-, femoral, metal/polymer, cemented or uncemented devices

All Prosthesis, hip, hemi-, femoral, metal/polymer, cemented or uncemented devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page