Worley™ Adv. LVI 00884450169797Recalls & reported problems

Merit Medical · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
1
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00884450169797), received between May 21, 2026 and May 21, 2026 — classified as 1 death.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 1 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Low Blood Pressure/ Hypotension1
  • Pericardial Effusion1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • DeathMay 21, 2026Adverse Event Without Identified Device or Use Problem

    CUSTOMER REPORTS A RIGHT VENTRICULAR LEAD WAS SUCCESSFULLY PLACED, THEN AN ATRIOVENTRICULAR NODE ABLATION WAS PERFORMED. LASTLY, CORONARY SINUS (CS) ACCESS WAS GAINED WITH THE WORLEY SYSTEM. WHILE SEARCHING FOR A VEIN TO IMPLANT THE LV LEAD, THE PATIENTS BLOOD PRESSURE DROPPED. AN EMERGENT ECHO WAS PERFORMED SHOWING A PERICARDIAL EFFUSION. A PERICARDIOCENTESIS WAS INITIATED AND FLUID WAS PULLED OFF THE PERICARDIUM. THE PATIENT KEPT HAVING PULSELESS ELECTRICAL ACTIVITY (PEA) EVENTS AND PULMONARY RESUSCITATION WAS INITIATED. EVENTUALLY THE PATIENT PASSED AND TIME OF DEATH WAS CALLED. IN REVIEW OF THE FLOURO IMAGES, THE WIRE WAS IN THE CS OUTSIDE OF THE CARDIAC SHADOW. THIS WAS BELIEVED TO BE THE CAUSE OF THE EFFUSION. FOLLOW-UP MDT REP COMMUNICATION: "YES, THE WORLEY WAS THOUGHT TO BE THE CAUSE."

    Patient problems: Low Blood Pressure/ Hypotension; Pericardial Effusion

    MAUDE report 25243523 ↗