Skip to content

Prelude SNAP™ 00884450251492Recalls & reported problems

Merit Medical · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00884450251492), received between Jul 29, 2025 and Jul 29, 2025 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Separation Failure” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 2 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Separation Failure2

Patient problems

  • No Clinical Signs, Symptoms or Conditions2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJul 29, 2025Separation Failure; Separation Failure

    ON (B)(6), 2025, A MERIT EMPLOYEE CONDUCTED A PMCF REVIEW FOR THE PRELUDE SNAP PRODUCT FAMILY. A PRELUDE SNAP SPLITTABLE SHEATH INTRODUCER WAS USED TO TREAT A FEMALE PATIENT >55 FOR THE INTRODUCTION OF SECONDARY DEVICE (E.G., PACING LEADS, CATHETERS) INTO THE HEART OR CORONARY VENOUS SYSTEM . THE PRIMARY USAGE OF THE DEVICE WAS TO FACILITATE PLACEMENT OF A DEVICE IN THE RIGHT VENTRICLE THROUGH THE V. CEPHALICA. THE DEVICE WAS USED FOR APPROXIMATELY 15 MINUTES. DURING THIS TIME THE PATIENT EXPERIENCED NO COMPLICATIONS. NO ADDITIONAL TREATMENT WAS REQUIRED HOWEVER, THE INNER SEALING RING DOES NOT BREAK.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22647400 ↗
  • MalfunctionJul 29, 2025Separation Failure; Separation Failure

    THE ACCOUNT ALLEGES DURING AN IMPLANT PROCEDURE, THE RA LEAD WAS INSERTED THROUGH THE SHEATH TO THE TARGET (RA APPENDAGE). WHEN THEY PHYSICIAN ATTEMPTED TO PEEL THE SHEATH IS TORE IN A SPIRAL MANNER STILL COVERING THE LEAD. THE PHYSICIAN HAD TO CAREFULLY CUT THE REST OF THE SHEATH. THE PROCEDURE WAS COMPLETED WITHOUT ADVERSE PATIENT CONSEQUENCES.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22647397 ↗

Other INTRODUCER, CATHETER devices

All INTRODUCER, CATHETER devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page