HeartSpan® 00884450286449Recalls & reported problems
Merit Medical · Class 2
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00884450286449), received between Apr 14, 2021 and Apr 14, 2021 — classified as 1 injury.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Pericardial Effusion1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryApr 14, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THE ACCOUNT ALLEGES THAT DURING AN A-FIB ABLATION PROCEDURE, WHILE PERFORMING A TRANSSEPTAL PUNCTURE THERE WAS DIFFICULTY VISUALIZING THROUGH THE TEE PROBE. THE PHYSICIAN MENTIONED THAT THE LEFT AND RIGHT ATRIUM WHERE DIFFERENTLY ORIENTATED THAN IN A NORMAL ANATOMY AND THE SEPTUM WAS TURNED TO A MORE POSTERIOR POSITION. THE FIRST TRANSSEPTAL PUNCTURE WAS SUCCESSFULLY COMPLETED WITH THE PREFACE SHEATH AND HEARTSPAN NEEDLE. NORMAL PRESSURES NOTED FROM WITHIN THE LEFT ATRIUM. THEN A SECONDARY PUNCTURE FOR A SECOND SHEATH, ONLY A FEW MILLIMETERS MORE POSTERIOR WAS ATTEMPTED. IT WAS NOT POSSIBLE TO SEE THE TIP OF THE NEEDLE ON ECHO [TENTING] DURING TRANSSEPTAL PUNCTURE. IT WAS NOTED THAT POST-SECOND HEARTSPAN NEEDLE/SHEATH PUNCTURE, THAT NO BLOOD WAS RETURNING, ONLY TRANSPARENT FLUID. VERY LOW PRESSURES WERE NOTED WITHIN THE PATIENT. AFTER GUIDE WIRE INSERTION, IT WAS CLEAR THAT THE SHEATH WAS INADVERTENTLY PLACED WITHIN THE EPICARDIAL SPACE. THIS WAS CONFIRMED BY ECHO. PATIENT REMAINED STABLE, NO HEMODYNAMIC CHANGES TO REPORT. PERICARDIAL EFFUSION WAS NOTED AND APPROXIMATELY 60ML'S OF FLUID WAS RETRACTED FROM THE PERICARDIAL SPACE. THE PATIENT HAD 2500 UNITS OF HEPARIN BEFORE PUNCT
Patient problems: Pericardial Effusion
MAUDE report 11667583 ↗
Other INTRODUCER, CATHETER devices
- VIZIGO D138502Biosense Webster Inc · INTRODUCER, CATHETER2 recalls4 deaths2,839 reports
- VIZIGO D138501Biosense Webster Inc · INTRODUCER, CATHETER2 recalls2 deaths2,005 reports
- Swartz™ 407451St. Jude Medical, Inc. · INTRODUCER, CATHETER5 deaths728 reports
- Edwards eSheath+ Introducer set 914ESPEdwards Lifesciences LLC · Introducer, Catheter22 deaths532 reports
- Fast-Cath™ 406849St. Jude Medical, Inc. · INTRODUCER, CATHETER420 reports
- VIZIGO D138503Biosense Webster Inc · INTRODUCER, CATHETER362 reports
- Agilis™ G408318St. Jude Medical, Inc. · INTRODUCER, CATHETER333 reports
- Agilis™ NxT Steerable Introducer Dual-Reach™ SI-1371-MSt. Jude Medical, Inc. · Introducer, catheter1 death301 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page