2F AND 3F VASCU-SHEATH TEARAWAY INTRODUCER2F AND 3F VASCU-SHEATH TEARAWAY INTROD MR190521Recalls & reported problems
Medical Components, Inc. · 5F (1.0 MM ID) X 9CM5F (1.0 MM I REGULAR MICRO-STICK® INTRODUCER SETINTRODUCER SET WITH NITINOL GUIDEWIREWITH NITIN WITH RADIOPAQUE TIPWITH RADIOPAQ · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00884908087666), received between Sep 18, 2018 and Nov 21, 2018 — classified as 2 injuries.
The most frequently reported specific device problem is “Break” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Break2
Patient problems
- Device Embedded In Tissue or Plaque2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryNov 21, 2018Break; Break
MICROWIRE GOT STUCK DURING SELDINGER TECHNIQUE AND UNRAVELED DURING REMOVAL. A SMALL PART OF THE WIRE WAS LEFT INSIDE THE SOFT TISSUE OF THE PATIENT'S GROIN.
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 8095097 ↗InjurySep 18, 2018Break; Break
WHILE ATTEMPTING TO GAIN ACCESS TO THE RIGHT INTERNAL JUGULAR VEIN EXPERIENCED WIRE AND INTRODUCER NEEDLE MISCOMMUNICATION. THE WIRE AND NEEDLE BECAME TWISTED TOGETHER AND DIFFICULT TO SEPARATE. MULTIPLE UNSUCCESSFUL ATTEMPTS WERE MADE TO SEPARATE THE TWO BY ADVANCING AND PULL BACK ON THE WIRE TO FREE IT FROM THE NEEDLE. IN AN ATTEMPT TO REMOVE THE WIRE AND THE NEEDLE OUT OF THE BODY SIMULTANEOUSLY THE TIP OF THE WIRE BROKE AND BEGAN TO UNRAVEL. SEVERAL ATTEMPTS WERE MADE TO RETRIEVE THE REMAINING 1.0 TO 1.5 CM PORTION OF WIRE. ULTIMATELY IT WAS DECIDED THAT IT WAS SAFER TO LEAVE IT IN THE PATIENT'S CHEST WALL. THE PATIENT WAS TRANSFERRED TO PACU IN SATISFACTORY CONDITION.
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 7885744 ↗
Other INTRODUCER, CATHETER devices
- VIZIGO D138502Biosense Webster Inc · INTRODUCER, CATHETER2 recalls4 deaths2,839 reports
- VIZIGO D138501Biosense Webster Inc · INTRODUCER, CATHETER2 recalls2 deaths2,005 reports
- Swartz™ 407451St. Jude Medical, Inc. · INTRODUCER, CATHETER5 deaths728 reports
- Edwards eSheath+ Introducer set 914ESPEdwards Lifesciences LLC · Introducer, Catheter22 deaths532 reports
- Fast-Cath™ 406849St. Jude Medical, Inc. · INTRODUCER, CATHETER420 reports
- VIZIGO D138503Biosense Webster Inc · INTRODUCER, CATHETER362 reports
- Agilis™ G408318St. Jude Medical, Inc. · INTRODUCER, CATHETER333 reports
- Agilis™ NxT Steerable Introducer Dual-Reach™ SI-1371-MSt. Jude Medical, Inc. · Introducer, catheter1 death301 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page