CD HORIZON® Spinal System 7576550Recalls & reported problems

Medtronic Sofamor Danek, Inc. · SCREW 7576550 LEGACY 5.5 CANN MAS 6.5X50 · Class 2 · Implant

All models of CD HORIZON Spinal System (342)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
7
Deaths reported
0
Injuries reported
4
Recalls naming it
0

Summary

The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 00885074031170), received between Mar 30, 2017 and Sep 28, 2026 — classified as 4 injuries, 3 malfunctions.

The most frequently reported specific device problem is “Break” (5 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 1 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 1 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break5
  • Detachment of Device or Device Component2
  • Adverse Event Without Identified Device or Use Problem1
  • Device Dislodged or Dislocated1

Patient problems

  • No Clinical Signs, Symptoms or Conditions5
  • No Code Available1
  • No Known Impact Or Consequence To Patient1
  • Pain1

Recent adverse event reports

The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 28, 2026Break

    Information was received from healthcare provider (HCP) via a manufacturer representative regarding screws used in Transforaminal Lu mbar Interbody Fusion therapy detected in MRI. It was reported that the screws broke. There were no patient symptoms reported. There were no further complications reported regarding the event.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50911052 ↗
  • MalfunctionDec 19, 2025Break; Detachment of Device or Device Component; Break; Detachment of Device or Device Component

    INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT HAVING TRANSFORAMINAL LUMBAR INTERBODY FUSION SPINAL THERAPY TO L1. IT WAS REPORTED THAT THE SEPARATION OF SCREW SHAFT AND HEAD ALONG WITH BREAKAGE WAS OBSERVED. THERE WAS NO PATIENT INVOLVED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23847919 ↗
  • InjuryJun 5, 2025Device Dislodged or Dislocated; Adverse Event Without Identified Device or Use Problem; Device Dislodged or Dislocated; Adverse Event Without Identified Device or Use Problem

    INFORMATION WAS RECEIVED FROM HEALTH CARE PROVIDER VIA MANUFACTURING REPRESENTATIVE REGARDING A PATIENT UNDERGONE 1 LEVEL MIS TLIF ( TRANSFORAMINAL LUMBAR INTERBODY FUSION). IT WAS REPORTED THAT SCREW DISLOCATED. REVISION SURGERY WAS PREFORMED BY REPLACING THE DISLOCATED SCREW WITH A BIGGER DIAMETER. NO PATIENT SYMPTOMS REPORTED. NO FRAGMENTS OF THE IMPLANT REMAINING IN THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22148021 ↗
  • MalfunctionSep 2, 2024Detachment of Device or Device Component; Detachment of Device or Device Component

    ADDITIONAL INFORMATION RECEIVED. SCREW WAS SEPARATED FROM THE SHANK. PROCEDURE PERFORMED WAS OPEN TRANSFORAMINAL LUMBAR INTERBODY FUSION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20116801 ↗
  • InjuryJul 28, 2023Break; Break

    INFORMATION WAS RECEIVED FROM A HEALTHCARE PROFESSIONAL VIA MANUFACTURER REPRESENTATIVE REGARDING A SCREW USED IN TLIF + PPF THERAPY FOR DDD (DEGENERATIVE DISC DISEASE). IT WAS REPORTED THAT THE SCREW BROKE. THE SCREW HEAD AND SHAFT WERE SEPARATED. THE RING PART IS BROKEN AND SEPARATED. THE OPERATION WAS DONE ON (B)(6) 2023 AND A REVISION SURGERY WAS PERFORMED ON (B)(6) 2023 TO REMOVE THE BROKEN SCREW AND INSERT A NEW SCREW. THERE WERE NO PATIENT SYMPTOMS. NO FURTHER COMPLICATIONS WERE REPORTED/ANTICIPATED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17412445 ↗
  • InjuryApr 3, 2020Break; Break

    IT WAS REPORTED THAT THE PATIENT UNDERWENT LUMBAR SPONDYLODESIS WITH TRANSFORAMINAL LUMBAR INTERBODY FUSION (TLIF) SURGERY AT L5-S1 DUE TO LUMBAR DISCOPATHY/SPONDYLISTHESIS. POST-OP, THE IMPLANTED SCREW WAS BROKEN AND DUE TO THIS LUMBAR IMPLANTED CAGE WAS SHIFTED TOWARD SPINAL CANAL. REVISION SURGERY WAS PERFORMED AS A RESULT OF THIS EVENT; WHERE REMOVAL OF THE ALLEGED SCREW PERFORMED. NO FRAGMENTS OF THE IMPLANT REMAIN IN PATIENT.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 9919420 ↗
  • InjuryMar 30, 2017Break; Break

    IT WAS REPORTED THAT PATIENT PRESENTED WITH PRE-OP DIAGNOSIS AS SPONDYLOLITHESIS (L5/S1). FOR WHICH PATIENT UNDERWENT, L5/S1 MINIMALLY INVASIVE FUSION USING SEXTANT REDUCTION AND CAPSTONE CAGE AT LEVELS L5/S1. ON AN UNKNOWN DATE, POST-OP, THE IMPLANTED SCREW BROKE. PATIENT EXPERIENCED PAIN DUE AS A RESULT OF BROKEN SCREW. THE PATIENT UNDERWENT REVISION SURGERY ON (B)(6) 2017. BOTH S1 SCREWS WERE REPLACED AND NEW RODS AND SET SCREWS HAVE BEEN IMPLANTED.

    Patient problems: No Code Available; Pain

    MAUDE report 6445202 ↗

Other Orthosis, spondylolisthesis spinal fixation devices