Skip to content

CD HORIZON® Spinal System 75495540Recalls & reported problems

Medtronic Sofamor Danek, Inc. · BONE SCREW 75495540 L5.5 RED MAS 5.5X40 · Class 2 · Implant

All models of CD HORIZON Spinal System (342)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00885074134444), received between Oct 6, 2022 and Oct 6, 2022 — classified as 1 malfunction.

The most frequently reported specific device problem is “Device Slipped” (1 report).

4 other recalls cover devices cleared under the same FDA submission (K042025); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Most reported problems

Device problems

  • Device Slipped1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionOct 6, 2022Device Slipped; Device Slipped

    INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT HAVING POSTERIOR LUMBAR INTERNAL FIXATION FOR AN INDICATION OF LUMBAR SPINE DEGENERATION. IT WAS REPORTED THAT THE SCREW SLIPPED DURING IMPLANTATION. THERE WERE NO PATIENT SYMPTOMS REPORTED. THERE WERE NO FURTHER COMPLICATIONS REPORTED REGARDING THE EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15548922 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K042025. One submission often covers many models, so check the product and lot details in each record.

  • Z-0465-2012 · Nov 30, 2011 · Terminated
    CD HORIZON (R) Spinal System, MULTI-AXIAL SCREW FOR 5.5mm ROD W/REDUCTION HEAD, Size 6.5mm X 40mm, Mat'l TITANIUM ALLOY, REF X1010484, Rx only, Medtronic Sofamor Danek USA, 1800 Py
  • Z-0464-2012 · Nov 30, 2011 · Terminated
    CD HORIZON (R) Spinal System, MULTI-AXIAL SCREW FOR 5.5mm ROD W/DUAL LEAD THREAD, Size 6.5mm X 40mm, Mat'l TITANIUM ALLOY, REF X0809439, Rx only, Medtronic Sofamor Danek USA, 1800
  • Z-2875-2011 · Jun 28, 2011 · Terminated
    CD HORIZON (R) LEGACY (TM) MAS, REF 75445540, pedicle screw, Rx only, Medtronic Sofamor Danek USA, 1800 Pyramid Place, Memphis, TN 38132 Intended to help provide immobilization a
  • Z-2878-2011 · Jun 28, 2011 · Terminated
    ATLANTIS (R) Self-Tapping Variable Angle Screw, Rx only, Medtronic Sofamor Danek USA, 1800 Pyramid Place, Memphis, TN 38132 Intended to help provide immobilization and stabilizat

Other Orthosis, spondylolisthesis spinal fixation devices

All Orthosis, spondylolisthesis spinal fixation devices →

Sources and updates