Skip to content

HEALICOIL REGENESORB 72203705Recalls & reported problems

Smith & Nephew, Inc. · HEALICOIL REGENESORB 4.75 MM SUTURE ANCHOR WITH ONE ULTRATAPE SUTURE BLUE AND ONE No.2 ULTRABRAID SUTURE · Class 2 · Implant

All models of HEALICOIL REGENESORB (4)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Quick summary

This Smith & Nephew HEALICOIL REGENESORB suture anchor is a biodegradable fastener used to secure soft tissue during shoulder and rotator cuff procedures. Its 39 adverse event reports mostly describe the anchor breaking or shattering while being inserted, sticking or jamming in the inserter, and the suture pulling loose or coming apart, sometimes leaving a small metal tip or a gap in the bone. Reports also mention reactions such as rash, pain, swelling, and inflammation. There were16 injuries and no deaths, and no recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
39
Deaths reported
0
Injuries reported
16
Recalls naming it
0

Summary

The FDA's MAUDE database contains 39 adverse event reports that list this exact device (DI 00885554031409), received between Aug 22, 2017 and May 14, 2026 — classified as 16 injuries, 23 malfunctions.

The most frequently reported specific device problem is “Break” (13 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 6 reportsOct 2024: 2 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 1 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 2 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 2 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520266
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break13
  • Mechanical Jam10
  • Adverse Event Without Identified Device or Use Problem9
  • Device Dislodged or Dislocated2
  • Detachment of Device or Device Component1
  • Device Slipped1
  • Difficult to Insert1
  • Fracture1

Patient problems

  • No Clinical Signs, Symptoms or Conditions21
  • Sepsis6
  • No Known Impact Or Consequence To Patient5
  • Perforation2
  • Device Embedded In Tissue or Plaque1
  • Foreign Body In Patient1
  • Hypersensitivity/Allergic reaction1
  • Inflammation1

Recent adverse event reports

The 25 most recent of 39 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 14, 2026Device Dislodged or Dislocated

    IT WAS REPORTED THAT, DURING A SHOULDER SCOPE, PATIENT HAD VERY SOFT POOR BONE, THE HEALICOIL ANCHOR WOULDN¿T HOLD. THERE WAS NOTHING WRONG WITH ANCHOR. THE PROCEDURE WAS COMPLETED WITH A SURGICAL DELAY OF LESS THAN 30 MINUTES BY KNOTTING THE LOOSE SUTURES. A VOID WAS LEFT IN THE PATIENT. NO FURTHER COMPLICATIONS WERE REPORTED. THE PATIENT STATUS WAS GOOD.

    Patient problems: Perforation

    MAUDE report 25172896 ↗
  • MalfunctionMay 1, 2026Device Dislodged or Dislocated

    IT WAS REPORTED THAT, DURING A SURGERY, AFTER THE INSERTION SITE WAS CLEARED OF ALL DEBRIS, WHEN A HEALICOIL ANCHOR WAS IMPLANTED AND THE INSERTER REMOVED FROM THE BONE HOLE, THE SUTURE CAME OUT. IT IS UNKNOWN IF THERE WAS A SURGICAL DELAY OR HOW THE PROCEDURE WAS COMPLETED. NO FURTHER COMPLICATIONS WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25062174 ↗
  • MalfunctionFeb 23, 2026Break

    IT WAS REPORTED THAT, DURING AN RCR PROCEDURE, DURING INSERTION, A HEALICOIL ANCHOR SHATTERED. ALL PIECES WERE REMOVED FROM THE PATIENT. THE PROCEDURE WAS RESUMED, AFTER A NON-SIGNIFICANT DELAY, USING AN EQUIVALENT S+N BACK-UP, IN THE ORIGINALLY DRILLED BONE HOLE. NO ADDITIONAL ANESTHESIA WAS REQUIRED. NO FURTHER COMPLICATIONS WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24413444 ↗
  • MalfunctionNov 13, 2025Break; Break

    IT WAS REPORTED THAT, DURING A ROTATOR CUFF PROCEDURE, AFTER THE HOLE WAS DRILLED, THE HEALICOIL ANCHOR WAS INSERTED INTO THE BONE CHANNEL AND DURING THE ROTATION AND INSERTION PROCESS, THE ANCHOR BROKE, MAKING IT UNUSABLE. THE BROKEN PIECES WERE REMOVED USING TWEEZERS. THE PROCEDURE WAS RESUMED, WITH A NON SIGNIFICANT DELAY, USING AN EQUIVALENT S+N BACK-UP. THE BACK UP DEVICE WAS USED IN THE ORIGINALLY DRILLED BONE HOLE, THERE WAS NO VOID LEFT IN THE PATIENT. NO FURTHER COMPLICATIONS WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23544652 ↗
  • InjuryNov 3, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT, AFTER A PROCEDURE ON (B)(6) 2025 USING A HEALICOIL REGENESORB, THE PATIENT EXPERIENCED ALLERGIC REACTION SYMPTOMS SINCE MID-MARCH. THE SYMPTOMS BEGAN ON THE SCALP AND THEN SPREAD TO THE TORSO. THE REACTIONS ARE HIVE-LIKE RAISED RED ITCHY RASH. VARIOUS DOCTORS HAVE TREATED IT WITH MEDICATIONS, LOTIONS AND PREDNISONE. PATIENT CURRENT STATUS IS UNKNOWN. NO FURTHER COMPLICATIONS WERE REPORTED.

    Patient problems: Hypersensitivity/Allergic reaction; Itching Sensation

    MAUDE report 23460351 ↗
  • MalfunctionAug 25, 2025Break; Break

    IT WAS REPORTED THAT, DURING SURGERY, THE HEALICOIL RSB ANCHOR BROKE WHILE IMPLANTATION IN THE PILOT HOLE. SURGERY WAS COMPLETED WITH A BACK-UP DEVICE, INSTEAD. THERE WAS A DELAY OF LESS THAN 30 MINUTES, AND NO FURTHER COMPLICATIONS WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22883334 ↗
  • InjuryMar 17, 2025Detachment of Device or Device Component; Detachment of Device or Device Component

    IT WAS REPORTED THAT DURING A SHOULDER ARTHROSCOPY, AFTER THE HEALICOIL ANCHOR WAS PLACED IN THE PATIENT'S SHOULDER, THE SURGEON NOTICED A PIECE OF METAL AT THE END OF THE ANCHOR AND THE SUTURES HAD SEPARATED FROM THE ANCHOR. AFTER REVIEWING THE DISTAL TIP OF THE ANCHOR INSERTER, IT WAS NOTICED THAT ONE SIDE OF THE METAL FORK WAS MISSING AND WAS LEFT INSIDE THE PATIENT. IT WAS BELIEVED THAT THE METAL TIP HAVE CUT THE PLASTIC TIP OF THE ANCHOR WHICH RELEASED THE SUTURES. THE PROCEDURE WAS COMPLETED WITH A SURGICAL DELAY OF LESS THAN 30 MINUTES USING A SMITH AND NEPHEW BACK UP DEVICE IN THE ORIGINALLY DRILLED HOLE. NO FURTHER COMPLICATIONS WERE REPORTED.

    Patient problems: Foreign Body In Patient

    MAUDE report 21627770 ↗
  • InjuryOct 2, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT APPROXIMATELY EIGHT MONTHS AFTER AN ARCR PROCEDURE PERFORMED ON (B)(6) 2024, TWO (2) HEALICOIL ANCHORS WERE USED, THE PATIENT EXPERIENCED SEVERAL ADVERSE EVENTS, FOR WHICH AN MRI WAS PERFORMED. SYNOVITIS AND RICE GRAIN-LIKE LESIONS WERE OBSERVED. FURTHERMORE, THE PATIENT HAD PAIN AND SWELLING. NO FURTHER COMPLICATIONS WERE REPORTED.

    Patient problems: Inflammation; Pain; Swelling/ Edema; Synovitis

    MAUDE report 20351980 ↗
  • MalfunctionOct 1, 2024Fracture; Fracture

    IT WAS REPORTED THAT, DURING A PROCEDURE, THE HEALICOIL ANCHOR WAS FRACTURED, WHEN IT WAS BEING INSERTED. SURGERY WAS COMPLETED WITH A BACK-UP DEVICE USED IN THE SAME DRILLED BONE HOLE, AND THERE WAS NO SURGICAL DELAY. ALL PIECES WERE REMOVED FROM THE PATIENT, AND NO FURTHER COMPLICATIONS WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20349435 ↗
  • InjurySep 20, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    FOLLOWING AN OPERATION ON (B)(6) 2024 ON A PATIENT´S LEFT SHOULDER ROTATOR CUFF REPAIR, A SECOND SURGERY FOR A SEPSIS LAVAGE HAD TO BE CARRIED OUT ON (B)(6) 2024 DUE TO INFECTION. A TOTAL OF TWO (2) HEALICOIL ANCHORS. IT IS UNKNOWN IF THE DEVICES WERE RETRIEVED FROM THE PATIENT. NO FURTHER COMPLICATIONS WERE REPORTED.

    Patient problems: Sepsis

    MAUDE report 20274405 ↗
  • InjurySep 20, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    FOLLOWING AN OPERATION ON (B)(6) 2024 ON A PATIENT´S RIGHT SHOULDER ROTATOR CUFF REPAIR, A SECOND SURGERY FOR A SEPSIS LAVAGE HAD TO BE CARRIED OUT ON (B)(6) 2024 DUE TO INFECTION. A HEALICOIL ANCHOR WAS USED IN THE PRIMARY SURGERY. IT IS UNKNOWN IF THE DEVICE WAS RETRIEVED FROM THE PATIENT. NO FURTHER COMPLICATIONS WERE REPORTED.

    Patient problems: Sepsis

    MAUDE report 20273768 ↗
  • InjurySep 20, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    FOLLOWING AN OPERATION ON (B)(6) 2024 ON A PATIENT´S RIGHT SHOULDER ROTATOR CUFF REPAIR, A SECOND SURGERY FOR A SEPSIS LAVAGE HAD TO BE CARRIED OUT ON (B)(6) 2024 DUE TO INFECTION. A HEALICOIL ANCHOR WAS USED IN THE PRIMARY SURGERY. IT IS UNKNOWN IF THE DEVICE WAS RETRIEVED FROM THE PATIENT. NO FURTHER COMPLICATIONS WERE REPORTED.

    Patient problems: Sepsis

    MAUDE report 20273738 ↗
  • InjurySep 17, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT, FOLLOWING AN OPERATION PERFORMED ON (B)(6) 2024 ON A PATIENT´S ROTATOR CUFF (RIGHT SHOULDER), A SECOND SURGERY FOR A SEPSIS LAVAGE HAD TO BE CARRIED OUT ON (B)(6) 2024 DUE TO INFECTION. A TOTAL OF TWO (2) HEALICOIL ANCHORS WERE USED IN THE PROCEDURE. ALL THE DEVICES STAYED IMPLANTED AND NO VOID WAS LEFT IN THE PATIENT. NO FURTHER COMPLICATIONS WERE REPORTED.

    Patient problems: Sepsis

    MAUDE report 20237327 ↗
  • InjurySep 17, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT, FOLLOWING AN OPERATION PERFORMED ON (B)(6) 2024 ON A PATIENT'S ROTATOR CUFF (RIGHT SHOULDER), A SECOND SURGERY FOR A SEPSIS LAVAGE HAD TO BE CARRIED OUT ON (B)(6) 2024 DUE TO INFECTION. A TOTAL OF TWO (2) HEALICOIL ANCHORS WERE USED IN THE PROCEDURE. ALL THE DEVICES STAYED IMPLANTED AND NO VOID WAS LEFT IN THE PATIENT. NO FURTHER COMPLICATIONS WERE REPORTED.

    Patient problems: Sepsis

    MAUDE report 20237253 ↗
  • InjurySep 16, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    FOLLOWING AN OPERATION ON (B)(6) 2024 ON A PATIENT´S RIGHT SHOULDER ROTATOR CUFF REPAIR, A SECOND SURGERY FOR A SEPSIS LAVAGE HAD TO BE CARRIED OUT ON (B)(6) 2024 DUE TO INFECTION. A HEALICOIL ANCHOR WAS USED IN THE PRIMARY SURGERY AND IT STAYED IMPLANTED IN THE PATIENT. NO FURTHER COMPLICATIONS WERE REPORTED.

    Patient problems: Sepsis

    MAUDE report 20226306 ↗
  • MalfunctionOct 6, 2023Break; Break

    IT WAS REPORTED THAT DURING AN UNSPECIFIED ARTHROSCOPY, THE HEALICOIL¿S TIP BROKE WHEN IT WAS BEING INSERTED IN THE BONE HOLE. ALL THE PIECES WERE REMOVED FROM THE PATIENT. THE PROCEDURE WAS COMPLETED WITH A S+N BACK UP DEVICE. THERE WAS NO SURGICAL DELAY AND NO FURTHER COMPLICATIONS WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17890132 ↗
  • MalfunctionJul 10, 2023Break; Break

    IT WAS REPORTED THAT DURING AN ARTHROSCOPY, TWO (2) HEALICOIL ANCHORS BROKE WHILE INSERTING INTO THE BONE HOLE. ALL THE BROKEN PIECES WERE SUCCESSFULLY REMOVED FROM THE PATIENT. IT IS UNKNOWN IF THERE WAS A DELAY. THE PROCEDURE WAS FINISHED WITH A SMITH AND NEPHEW BACK UP DEVICE. NO FURTHER COMPLICATIONS WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17288198 ↗
  • InjuryMay 11, 2022Break; Break

    IT WAS REPORTED THAT DURING A ROTATOR CUFF REPAIR, THE TOP PART OF THE 'HEALICOIL' ANCHOR BROKE AFTER BEING IMPLANTED. A FULLY THREADED 4.75 AWL WAS USED AS USUAL FOR BONE PREPARATION. MOST OF THE ANCHOR PULLED OUT OF THE HOLE, THE BROKEN PIECE WAS REMOVED FROM PATIENT USING GRASPERS. THIS RESULTED IN A NON-SIGNIFICANT SURGICAL DELAY. THE PROCEDURE WAS COMPLETED USING THE SAME DEVICE AS THE BOTTOM PART OF THE ANCHOR HOLDING THE SUTURES WAS STILL FIRM INSIDE THE DRILL HOLE AND NO FURTHER COMPLICATIONS WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14352660 ↗
  • InjuryApr 24, 2022Break; Break

    IT WAS REPORTED THAT, DURING A ROTATOR CUFF REPAIR AND A BICEPS TENODESIS, THE HEALICOIL BROKE AFTER BEING ALREADY IMPLANTED, MOST OF THE ANCHOR PULLED OUT OF THE HOLE. THE FULLY THREADED 4.75 AWL WAS USED AS USUAL. ALL THE LOOSE PIECES WERE REMOVED BUT NOT THE PART THAT HELD UP IN THE BONE, HOLDING THE SUTURES. THE PIECES WERE REMOVED WITH A GRASPER. THE PROCEDURE WAS COMPLETED WITH A S+N BACK UP DEVICE. THE BACK UP DEVICE WAS USED IN AN ADDITIONAL BONE HOLE, NO VOID WAS LEFT IN THE PATIENT. THE INSERTION SITE WAS CLEARED OF ALL DEBRIS PRIOR TO INSERTION, THE SURGEON WAS SATISFIED WITH THE SURGICAL OUTCOME. THERE WAS A NON-SIGNIFICANT DELAY AND NO FURTHER COMPLICATIONS WERE REPORTED.

    Patient problems: Device Embedded In Tissue or Plaque; No Clinical Signs, Symptoms or Conditions; Rupture

    MAUDE report 14191321 ↗
  • InjuryApr 22, 2022Break; Break

    IT WAS REPORTED THAT DURING A ROTATOR CUFF REPAIR, THE HEALICOIL ANCHOR'S THREAD GOT BROKEN WHILE GETTING DEPLOYED. ALL THE PIECES WERE REMOVED FROM THE PATIENT BY SUCTION. THE PROCEDURE WAS SUCCESSFULLY COMPLETED WITH A SURGICAL DELAY OF 1-2 MINUTES USING A BACK-UP DEVICE. NO OTHER COMPLICATIONS WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14184330 ↗
  • InjuryOct 5, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT AFTER AN ARTHROSCOPY WHERE A HEALICOIL WAS USED, THE PATIENT HAD FROZEN SHOULDER RIGHT SIDE. THE PROCEDURE WAS FINISHED WITH THE SAME DEVICE. NO DELAY WAS REPORTED. THE TREATMENT USED WAS MANIPULATION UNDER ANESTHESIA. THE OUTCOME WAS RESOLVED.

    Patient problems: Loss of Range of Motion

    MAUDE report 12575697 ↗
  • MalfunctionJun 21, 2021Difficult to Insert; Difficult to Insert

    IT WAS REPORTED THAT DURING THE ARCR PROCEDURE, WHEN THE HEALICOIL ANCHOR WAS INSERTED AND PULLED THE TAPE AND SUTURE, BUT ONLY THE SUTURE COULD NOT BE SLIP. BONE HOLE WAS MADE USING A 4.75 DILATOR. THE PROCEDURE WAS COMPLETED WITH A BACKUP ANCHOR INSERTED IN THE SAME BONE HOLE. NO PATIENT INJURY OR DELAY WAS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12037374 ↗
  • InjuryDec 19, 2020Mechanical Jam; Mechanical Jam

    IT WAS REPORTED THAT ONCE THE HEALICOIL WAS INSERTED CORRECTLY, THE TAPE THAT THE PRODUCT ACCOMMODATES TOGETHER WITH A THREAD DOES NOT SLIDE INSIDE THE PRODUCT, MAKING IT IMPOSSIBLE TO MAKE A SLIDING KNOT, WHICH IS ESSENTIAL FOR TIGHTENING THE BREAK CLOSURE SYSTEM. A FLAP OF TISSUE REMAINS AT THE ANTERIOR LEVEL OF THE SUPRASPINATUS TENDON. THE PROBLEM DID NOT LEAD TO ANY COMPLICATION BUT THE TECHNIQUE COULD NOT BE PERFORMED AS USUAL. THE PROCEDURE WAS COMPLETED WITH THE SAME DEVICE AND NO SIGNIFICANT DELAY OR FURTHER COMPLICATIONS WERE REPORTED. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11043004 ↗
  • MalfunctionDec 16, 2020Mechanical Jam; Mechanical Jam

    IT WAS REPORTED THAT ONCE THE HEALICOIL WAS INSERTED CORRECTLY, THE TAPE THAT THE PRODUCT ACCOMMODATES TOGETHER WITH A THREAD DOES NOT SLIDE INSIDE THE PRODUCT, MAKING IT IMPOSSIBLE TO MAKE A SLIDING KNOT, WHICH IS ESSENTIAL FOR TIGHTENING THE BREAK CLOSURE SYSTEM. A FLAP OF TISSUE REMAINS AT THE ANTERIOR LEVEL OF THE SUPRASPINATUS TENDON. THE PROBLEM DID NOT LEAD TO ANY COMPLICATION BUT THE TECHNIQUE COULD NOT BE PERFORMED AS USUAL. THE PROCEDURE WAS COMPLETED WITH THE SAME DEVICE AND NO SIGNIFICANT DELAY OR FURTHER COMPLICATIONS WERE REPORTED. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11015757 ↗
  • MalfunctionDec 16, 2020Mechanical Jam; Mechanical Jam

    IT WAS REPORTED THAT ONCE THE HEALICOIL WAS INSERTED CORRECTLY, THE TAPE THAT THE PRODUCT ACCOMMODATES TOGETHER WITH A THREAD DOES NOT SLIDE INSIDE THE PRODUCT, MAKING IT IMPOSSIBLE TO MAKE A SLIDING KNOT, WHICH IS ESSENTIAL FOR TIGHTENING THE BREAK CLOSURE SYSTEM. A FLAP OF TISSUE REMAINS AT THE ANTERIOR LEVEL OF THE SUPRASPINATUS TENDON. THE PROBLEM DID NOT LEAD TO ANY COMPLICATION BUT THE TECHNIQUE COULD NOT BE PERFORMED AS USUAL. THE PROCEDURE WAS COMPLETED WITH THE SAME DEVICE AND NO SIGNIFICANT DELAY OR FURTHER COMPLICATIONS WERE REPORTED. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11015649 ↗

Other Fastener, fixation, biodegradable, soft tissue devices

All Fastener, fixation, biodegradable, soft tissue devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page