Skip to content

BIOSURE 72204410Recalls & reported problems

Smith & Nephew, Inc. · BIOSURE REGENSORB INTERFERENCE SCREW 10 MM X 35 MM · Class 2 · Implant

All models of BIOSURE (68)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
5
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00885554036862), received between Jun 16, 2018 and Aug 23, 2024 — classified as 1 injury, 4 malfunctions.

The most frequently reported specific device problem is “Break” (5 reports).

1 other recall cover devices cleared under the same FDA submission (K142948); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 1 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break5
  • Fracture1
  • Material Deformation1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3
  • No Consequences Or Impact To Patient1
  • No Known Impact Or Consequence To Patient1

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • MalfunctionAug 23, 2024Break; Break

    IT WAS REPORTED THAT, DURING A RE-REVISION ACL RECONSTRUCTION PROCEDURE, THE BIOSURE REGENESORB SCREW BROKE WHILE SCREWING IT IN, BROKEN PIECES WERE REMOVED USING A GRASPER. SURGERY WAS COMPLETED WITH A BACK-UP DEVICE INSTEAD IN THE ORIGINAL HOLE. THERE WAS A SURGICAL DELAY OF LESS THAN 30 MINUTES, AND NO FURTHER COMPLICATIONS WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20055157 ↗
  • MalfunctionJan 3, 2024Break; Fracture; Material Deformation; Break; Fracture; Material Deformation

    IT WAS REPORTED THAT DURING AN ARTHROSCOPY, THE BIORSURE SCREW WAS WEAKENED. WHEN PASSING THE SCREW, IT BECAME UNTHREADED AND REMAINED SMOOTH. THE PROCEDURE WAS COMPLETED WITH NON-SIGNIFICANT DELAY USING A COMPETITOR DEVICE. NO FURTHER COMPLICATIONS WERE REPORTED. UPON INVESTIGATION, IT WAS FOUND A FRACTURE OF THE THREADS OF THE PROXIMAL THIRD OF THE DEVICE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18441269 ↗
  • InjuryMay 25, 2022Break; Break

    IT WAS REPORTED THAT DURING AN ARTHROSCOPY PROCEDURE, AFTER DRILLING THE TIBIAL TUNNEL WITH A 10MM DRILL, THE BIOSURE REGENESORB SCREW WAS INSERTED WITH THE NITINOL GUIDE AND, WHEN IMPLANTING, IT BROKE INTO 4 PIECES, THE GUIDE AND THE SCREW PARTS WERE REMOVED OF THE TIBIAL TUNNEL. THE PROCEDURE WAS SUCCESSFULLY COMPLETED WITH A SURGICAL DELAY OF 30 MINUTES USING A BACK-UP DEVICE. NO PATIENT COMPLICATIONS WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14493770 ↗
  • MalfunctionAug 1, 2018Break

    IT WAS REPORTED THAT THE SCREW BROKE INSIDE WHILE PUTTING IN THE TUNNEL. NO PATIENT INJURY WAS REPORTED. IT IS UNKNOWN IF THERE WAS A BACK UP OR IF THERE WAS A DELAY.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 7739197 ↗
  • MalfunctionJun 16, 2018Break

    IT WAS REPORTED THAT UNIT GOT DAMAGED/BREAKAGE DURING THE SURGERY. ALL BROKEN PIECES WERE REMOVED. A BACKUP DEVICE WAS AVAILABLE TO COMPLETE THE PROCEDURE WITH NO DELAY OR PATIENT INJURIES.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 7608438 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K142948. One submission often covers many models, so check the product and lot details in each record.

  • Z-0957-2026 · Nov 24, 2025 · Open, Classified
    BIOSURE HA SCREW, 6MM x 20 MM. Threaded metallic bone fixation fastener.

Other Fastener, fixation, biodegradable, soft tissue devices

All Fastener, fixation, biodegradable, soft tissue devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page