Smith & Nephew, Inc. · EVOS LARGE TARGETER 3.7MM DRILL W/AO QC · Class 1

All models of EVOS (190)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00885556767733), received between Jun 30, 2023 and Jun 12, 2024 — classified as 1 injury, 1 malfunction.

The most frequently reported specific device problem is “Fracture” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fracture1
  • Material Fragmentation1
  • Mechanical Jam1
  • Separation Failure1

Patient problems

  • Device Embedded In Tissue or Plaque1
  • Foreign Body In Patient1
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJun 12, 2024Material Fragmentation; Separation Failure; Mechanical Jam; Material Fragmentation; Separation Failure; Mechanical Jam

    IT WAS REPORTED THAT, DURING EVOS LARGE PP INTERNAL FIXATION SURGERY, ONE (1) EVOS LARGE TGTR 3.7MM R DRILL GOT JAMMED IN THE DRILL SLEEVE, AFTER PENETRATING THE NEAR CORTEX. THE PROCEDURE WAS RESUMED, AFTER A NON-SIGNIFICANT DELAY, USING A S+N BACK-UP DEVICE. AFTER THE PROCEDURE, THE PARTS WERE SEPARATED EXHIBITING SMALL AMOUNTS OF METAL DEBRIS PRESUMABLY COMING FROM THE DRILL FLUTES. NO FURTHER COMPLICATIONS WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19520912 ↗
  • InjuryJun 30, 2023Fracture; Fracture

    IT WAS REPORTED THAT, DURING SURGERY, IT WAS NOTICED THAT, TWO (2) EVOS LARGE TGTR 3.7MM R DRILL BROKE EVEN WITH USE OF TARGETED DRILL GUIDE. DRILL BIT BROKE WHEN WAS BEING USED TO DRILL PILOT HOLE IN DISTAL FEMUR OF PATIENT. PATIENT RECEIVED A RETRO NAIL SIZE 13X22 AND A 14HOLE PERI PROS DISTAL FEMUR PLATE. ONLY ONE OF THE TWO DRILL BITS WAS SUCCESSFULLY RETRIEVED. THE OTHER WAS RETAINED IN THE PATIENT. THE PROCEDURE WAS RESUMED, AFTER A NON-SIGNIFICANT DELAY, WITH A S+N BACK-UP DEVICE. PATIENT WAS NOT INJURED AS CONSEQUENCE OF THIS PROBLEM.