ENGAGE 1-10013-609Recalls & reported problems
Smith & Nephew, Inc. · TIBIAL INSERT SIZE 6-LEFT MED 9MM · Class 2 · Implant
All models of ENGAGE (80)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 1
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00885556874028), received between May 24, 2023 and May 26, 2023 — classified as 2 injuries.
The most frequently reported specific device problem is “Naturally Worn” (1 report).
1 FDA recall record name this device's identifier, 1 still open.
4 other recalls cover devices cleared under the same FDA submission (K190439, K230653); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Recalls naming this device
- May 2, 2023Class IIOpen, Classified
Recent complaint data indicates that the revision rate may be trending higher than corresponding similar devices in global joint replacement registries. The data identifies a potential signal that the performance is an outlier versus the state of the art with respect to the risk for revision.
Z-1673-2023 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
- Naturally Worn1
Patient problems
- Failure of Implant1
- Implant Pain1
- Inadequate Osseointegration1
- Joint Dislocation1
- Pain1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryMay 26, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT, AFTER UKA SURGERY WAS PERFORMED ON (B)(6)2021, AP X-RAYS DEMONSTRATED TIBIAL COLLAPSE WHERE TIBIAL IMPLANT WAS ROTATED IN VALGUS. THIS ADVERSE EVENT WAS TREATED WITH REVISION SURGERY ON (B)(6)2021 (5 WEES POST-OP) FROM A UKA TO TKA. DURING THIS PROCEDURE, IT WAS OBSERVED THAT THE BONE QUALITY WAS VERY POOR. IT WAS DETERMINED THAT A CEMENTED TOTAL KNEE ARTHROPLASTY SHOULD HAVE BEEN PERFORMED INSTEAD AS INITIAL SURGERY, SINCE THE PATIENT WAS NOT A GOOD CANDIDATE FOR A UKA. THE SURGEON WAS ABLE TO LIFT THE TIBIAL TRAY & ANCHOR OUT OF THE PATIENT WITH A RONGEUR BY HAND. REVISION PROCEDURE FROM UKA TO TKA WAS SUCCESSFULLY COMPLETED. BASED ON THE INFORMATION PROVIDED BY 3 INDEPENDENT INDIVIDUALS, INCLUDING 2 TRAINED ORTHOPEDIC MEDICAL DOCTORS, THE CAUSE OF THE INCIDENT WAS POOR BONE QUALITY OF THE PATIENT, AND THE DEVICE DID NOT CAUSE OR CONTRIBUTE TO THE INCIDENT.
Patient problems: Joint Dislocation; Pain
MAUDE report 17011486 ↗InjuryMay 24, 2023Naturally Worn; Naturally Worn
IT WAS REPORTED THAT, AFTER LEFT PARTIAL KNEE REPLACEMENT SURGERY HAD BEEN PERFORMED ON (B)(6) 2022, THE PATIENT EXPERIENCED PAIN ON THE LEFT KNEE. THIS ADVERSE EVENT WAS SOLVED BY REVISION SURGERY PERFORMED ON (B)(6) 2023, IN WHICH ALL FOUR (4) COMPONENTS WERE REVISED, AND COMPETITOR DEVICE WERE IMPLANTED. THE ENGAGE POROUS FEMORAL SZ 7-LT MED HAD NO VISIBLE BONE INGROWTH, THE ENGAGE POROUS TIBIAL TRAY SZ 6-LT MED HAD MINIMAL BONE INGROWTH AND THE ENGAGE TIBIAL INSERT SZ 6-LT MED 9MM HAD VISIBLE WEAR. CURRENT HEALTH STATUS OF PATIENT IS UNKNOWN.
Patient problems: Failure of Implant; Implant Pain; Inadequate Osseointegration
MAUDE report 16992262 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K190439, K230653. One submission often covers many models, so check the product and lot details in each record.
- Z-2621-2023 · Aug 31, 2023 · Open, Classifiedsmith&nephew LEGION OXINUM POSTERIOR STABILIZED NONPOROUS FERMOAL COMPONENT, SIZE 5N, LEFT, NARROW, REF 71421265; knee joint
- Z-1672-2023 · May 2, 2023 · Open, ClassifiedSmith&Nephew ENGAGE Cementless Partial Knee System, Coated Tibial Tray, Part Numbers: a) REF 1-10012-100, SIZE 1-LEFT MEDIAL; b) REF 1-10012-150, SIZE 1-RIGHT MEDIAL; c) REF 1-1
- Z-1670-2023 · May 2, 2023 · Open, ClassifiedSmith&Nephew ENGAGE Cementless Partial Knee System, Porous Femoral components, Part Numbers: a) REF 1-10003-100 (SIZE 1 Right Medial); b) REF 1-10003-110 (SIZE 1 Left Medial);
- Z-1671-2023 · May 2, 2023 · Open, ClassifiedSmith&Nephew ENGAGE Cementless Partial Knee System, Tibial Anchor Stem, Part Numbers: a) REF 1-10011-100 (SIZE 1-2), b) REF 1-10011-200 (SIZE 3-4), c) REF 1-10011-300 (SIZE 5-6
Other PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER devices
- LinkSymphoKnee 880-307/21WALDEMAR LINK GmbH & Co. KG · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER2 recalls2 reports
- Scorpio 73-3710Howmedica Osteonics Corp. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER2 recalls1 report
- Scorpio 73-3110Howmedica Osteonics Corp. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER2 recalls0 reports
- Arthrex® AR-503-TTTEArthrex, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER1 recall14 reports
- Arthrex® AR-503-TTTJArthrex, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER1 recall9 reports
- ENGAGE 1-10011-300Smith & Nephew, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER1 recall7 reports
- Arthrex® AR-503-TTTGArthrex, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER1 recall7 reports
- ENGAGE 1-10003-400Smith & Nephew, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER1 recall6 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026 · each recall links to the FDA recall notice
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page