Occlutech Delivery Set III 98US006Recalls & reported problems

Oscor Inc. · OCCLUTECH DELIVERY SET III, 6F 79CM 180° · Class 2

All models of Occlutech Delivery Set III (10)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00885672010195), received between Aug 8, 2025 and Aug 8, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 1 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break1
  • Difficult to Advance1
  • Fluid/Blood Leak1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionAug 8, 2025Break; Fluid/Blood Leak; Difficult to Advance; Break; Fluid/Blood Leak; Difficult to Advance

    THE CUSTOMER STATED THAT DURING AN IMPLANT PROCEDURE (PATIENT INVOLVED), THE PHYSICIAN USED AN MVSD 6 MM DEVICE, WHICH SHOULD BE COMPATIBLE WITH THE ODS III 6F DELIVERY SET. THE DEVICE WAS INSPECTED PRIOR TO USE. HOWEVER, UPON REACHING THE CURVED PART OF THE DELIVERY SET, THE CABLE COULD NOT ADVANCE FURTHER. IT LOST PUSHABILITY AND WAS NO LONGER RESPONSIVE, PREVENTING PROPER DEPLOYMENT. AS A RESULT, PHYSICIAN UPSIZED TO AN ODS III 7F (98US007, LOT; DP-21419), AFTER WHICH THE DEVICE WAS SUCCESSFULLY DEPLOYED. THE PATIENT RECOVERED AND EVENT RESOLVED. ADDITIONALLY, A PART OF THE LOADER CAME OUT OF PLACE WHILE ADVANCING THE DEVICE, WHICH RESULTED IN BLOOD SPILLAGE. THE ISSUE IS RELATED TO THE COMPATIBILITY PROBLEM BETWEEN THE MVSD 6 MM AND ODSIII 6F. CLINICALLY SIGNIFICANT EXTENDED TREATMENT OR PROCEDURE TIME. THE AFFECTED ODSIII WAS DISCARDED BY THE HOSPITAL. PLEASE FIND THE PICTURES ATTACHED AS PROVIDED BY CUSTOMER. THERE WAS A DELAY, LESS THAN 30 MINUTES. NO MEDICAL OR SURGICAL INTERVENTION WAS REQUIRED. THE PROCEDURE WAS COMPLETED SUCCESSFULLY USING THE 7F DELIVERY SET. THE PATIENT'S ANATOMY WAS NORMAL, WITH NO ABNORMALITIES OR CHALLENGES NOTED DURING THE PROCEDURE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22751071 ↗