Occlutech Delivery Set III 98DS010Recalls & reported problems
Oscor Inc. · OCCLUTECH DELIVERY SET III, 10F 79CM 45° · Class 2
All models of Occlutech Delivery Set III (10)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00885672010300), received between Aug 2, 2023 and Mar 17, 2025 — classified as 1 injury, 2 malfunctions.
The most frequently reported specific device problem is “Fluid/Blood Leak” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Fluid/Blood Leak2
- Air/Gas in Device1
- Detachment of Device or Device Component1
- Infusion or Flow Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
- Air Embolism1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
InjuryMar 17, 2025Fluid/Blood Leak; Infusion or Flow Problem; Fluid/Blood Leak; Infusion or Flow Problem
PRIOR TO IMPLANTATION OCCLUDER WAS FLUSHED, LOADED 2X AND ALWAYS FLUSHED WITH WATER TO REMOVE AIR BUBBLES FROM THE DEVICE AND MATERIAL. SHEATH WAS FLUSHED AS WELL AND ONCE PLACED IN THE PATIENT WE ASPIRATED 20ML OF BLOOD TO REMOVE AIR FROM THE SHEATH AFTER DILATOR REMOVAL. THEN LOADER TOGETHER WITH THE OCCLUDER WAS UNDER CONSTANT FLUSH CONNECTED TO THE DELIVERY SHEATH. AFTER THE LEFT SIDE OF THE OCCLUDER WAS DEPLOYED ECG HAS CHANGED AND THE PATIENT FELT CHEST PAIN AND SHORTNESS OF BREATH. AIR EMBOLIE WAS SUSPECTED. AFTER 5-7 MIN ECG WAS AGAIN NORMAL AND THE CHEST PAIN WAS LESS PRESENT IN THE PATIENT. THE DEVICE WAS IMPLANTED, AND THE PATIENT WAS DISCHARGED WITHOUT ANY CONSEQUENCES. DEVICE WAS DISCARDED BY HOSPITAL. CONSEQUENCES TO EVENT: AIR ENTERING INTO VASCULAR SYSTEM & EMBOLISM. (B)(6)2025: CUSTOMER PROVIDED ADDITIONAL DETAILS: PROCEDURE TAKING PLACE WHEN ISSUE WAS FOUND WAS TO CLOSE THE PFO (PATENTED FORAMEN OVALE). IT IS UNKNOWN EXACTLY WHEN THE AIR GOT INTO THE DEVICE BUT IT WAS NOTICED (ECG CHANGED AND PATIENT COMPLAINED ABOUT THE CHEST PAIN AND BREATHING ISSUES) SHORTLY AFTER THE LEFT SIDE OF THE PFO DEVICE WAS DEPLOYED. THERE WAS A SHORT DELAY OF 10-15 MORE MINUTES UNTIL
Patient problems: Air Embolism
MAUDE report 21621822 ↗MalfunctionJun 28, 2024Detachment of Device or Device Component; Detachment of Device or Device Component
DURING THE PREPARATION, THE LOADER WAS IN THE WATER, OUR FLEX PUSHER WAS IN THE LOADER AND THE USER JUST WANTED TO CONNECT THE PUSHER WITH THE BALL CONNECTOR ON THE OCCLUDER. IN THIS MOMENT I SAW THERE IS SOMETHING WRONG, THE USER PUT IT OUT OF WATER AND THE PINK HALF RING WAS NOT ON ITS PLACE. ANOTHER DEVICE USED TO COMPLETE PROCEDURE. NO PATIENT INVOLVEMENT REPORTED, NO ADDITIONAL INFORMATION AVAILABLE,
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19632519 ↗MalfunctionAug 2, 2023Fluid/Blood Leak; Air/Gas in Device; Fluid/Blood Leak; Air/Gas in Device
DURING AN ASD IMPLANT PROCEDURE, WHEN FLUSHING LOADED ASD DEVICE WITHIN THE LOADER PRIOR TO PLACEMENT INTO DELIVERY SHEATH, AIR BUBBLES COULD BE SEEN ENTERING THE LOADER CHAMBER VIA THE HEMOSTATIC VALVE AT THE PROXIMAL END THROUGH WHICH THE PUSHER WAS PASSED. PLACING A THUMB OVER THE DISTAL END OF THE LOADER AND FLUSHING RESULTED IN LIQUID SQUIRTING THROUGH HEMOSTATIC VALVE AT LOW PRESSURE, LOADER VALVE INTEGRITY. ALL BUBBLES WERE SUCCESSFULLY FLUSHED, AND CASE WENT AHEAD SUCCESSFULLY. LOADER IS AVAILABLE FOR RETURN AND ANALYSIS. CASE ENDED IN SUCCESSFUL POSITIONING OF ASD DEVICE. CUSTOMER COMPLAINT ONLY RELATES TO VALVE ON LOADER, REMAINDER OF ODSIII KIT FUNCTIONED APPROPRIATELY."
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17443094 ↗
Other INTRODUCER, CATHETER devices
- VIZIGO D138502Biosense Webster Inc · INTRODUCER, CATHETER2 recalls4 deaths2,839 reports
- VIZIGO D138501Biosense Webster Inc · INTRODUCER, CATHETER2 recalls2 deaths2,005 reports
- Swartz™ 407451St. Jude Medical, Inc. · INTRODUCER, CATHETER5 deaths728 reports
- Edwards eSheath+ Introducer set 914ESPEdwards Lifesciences LLC · Introducer, Catheter22 deaths532 reports
- Fast-Cath™ 406849St. Jude Medical, Inc. · INTRODUCER, CATHETER420 reports
- VIZIGO D138503Biosense Webster Inc · INTRODUCER, CATHETER362 reports
- Agilis™ G408318St. Jude Medical, Inc. · INTRODUCER, CATHETER333 reports
- Agilis™ NxT Steerable Introducer Dual-Reach™ SI-1371-MSt. Jude Medical, Inc. · Introducer, catheter1 death301 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page